These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

145 related articles for article (PubMed ID: 3400852)

  • 21. Advantage of rubber over plastic endotracheal tubes for rapid extubation in a laser fire.
    Sosis MB; Braverman B
    J Clin Laser Med Surg; 1996 Apr; 14(2):93-5. PubMed ID: 9484083
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Effect of positive expiratory pressure and type of tracheal cuff on the incidence of aspiration in mechanically ventilated patients in an intensive care unit.
    Lucangelo U; Zin WA; Antonaglia V; Petrucci L; Viviani M; Buscema G; Borelli M; Berlot G
    Crit Care Med; 2008 Feb; 36(2):409-13. PubMed ID: 18007268
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Bronchial cuff pressures of double-lumen tubes.
    Brodsky JB; Adkins MO; Gaba DM
    Anesth Analg; 1989 Nov; 69(5):608-10. PubMed ID: 2802196
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A comparison of CO2 laser ignition of the Xomed, PVC and rubber tracheal tubes.
    Sosis M; Dillon F; Harwood T
    Can J Anaesth; 1990 May; 37(4 Pt 2):S87. PubMed ID: 2361324
    [No Abstract]   [Full Text] [Related]  

  • 25. Systemic absorption of lignocaine ointment from tracheal tubes.
    Sellers WF; Dye A; Harvey J
    Anaesthesia; 1985 May; 40(5):483-5. PubMed ID: 4014626
    [TBL] [Abstract][Full Text] [Related]  

  • 26. The effect of blood on laser-resistant endotracheal tube combustion.
    Sosis MB; Pritikin JB; Caldarelli DD
    Laryngoscope; 1994 Jul; 104(7):829-31. PubMed ID: 8022244
    [TBL] [Abstract][Full Text] [Related]  

  • 27. The comparison of insertion depth for orotracheal intubation between standard polyvinyl chloride tracheal tubes and straight reinforced tracheal tubes.
    Kim JE; Park SW; Kang JM
    J Clin Anesth; 2016 Jun; 31():90-3. PubMed ID: 27185684
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Polyurethane does not protect better than polyvinyl cuffed tracheal tubes from microaspirations.
    Bulpa P; Evrard P; Bouhon S; Schryvers F; Jamart J; Michaux I; Dive A; Vander Borght T; Krug B
    Minerva Anestesiol; 2013 May; 79(5):498-503. PubMed ID: 23511349
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Cuff inflation-supplemented laryngoscope-guided nasal intubation: a comparison of three endotracheal tubes.
    Kumar R; Gupta E; Kumar S; Rani Sharma K; Rani Gupta N
    Anesth Analg; 2013 Mar; 116(3):619-24. PubMed ID: 23400994
    [TBL] [Abstract][Full Text] [Related]  

  • 30. The Microcuff tube allows a longer time interval until unsafe cuff pressures are reached in children.
    Dullenkopf A; Gerber A; Weiss M
    Can J Anaesth; 2004 Dec; 51(10):997-1001. PubMed ID: 15574550
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Randomized intubation with polyurethane or conical cuffs to prevent pneumonia in ventilated patients.
    Philippart F; Gaudry S; Quinquis L; Lau N; Ouanes I; Touati S; Nguyen JC; Branger C; Faibis F; Mastouri M; Forceville X; Abroug F; Ricard JD; Grabar S; Misset B;
    Am J Respir Crit Care Med; 2015 Mar; 191(6):637-45. PubMed ID: 25584431
    [TBL] [Abstract][Full Text] [Related]  

  • 32. A comparison of a silicone wire-reinforced tube with the Parker and polyvinyl chloride tubes for tracheal intubation through an intubating laryngeal mask airway in patients with normal airways undergoing general anesthesia.
    Kanazi GE; El-Khatib M; Nasr VG; Kaddoum R; Al-Alami A; Baraka AS; Ayoub CM
    Anesth Analg; 2008 Sep; 107(3):994-7. PubMed ID: 18713919
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Tracheal sealing by auto-inflation in tracheal tube cuffs.
    Weiss M; Shorten G; Stutz K; Bernet V
    Paediatr Anaesth; 2007 Mar; 17(3):243-8. PubMed ID: 17263739
    [TBL] [Abstract][Full Text] [Related]  

  • 34. The effects of lidocaine spray and intracuff alkalinized lidocaine on the occurrence of cough at extubation: a double-blind randomized controlled trial.
    D'Aragon F; Beaudet N; Gagnon V; Martin R; Sansoucy Y
    Can J Anaesth; 2013 Apr; 60(4):370-6. PubMed ID: 23370978
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Outer diameter and shape of paediatric tracheal tube cuffs at higher inflation pressures.
    Bernet V; Dullenkopf A; Maino P; Weiss M
    Anaesthesia; 2005 Nov; 60(11):1123-8. PubMed ID: 16229698
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Effect of Lanz pressure regulating valve on self-sealing mechanism and air leakage across the tracheal tube cuffs in a benchtop model.
    Dave MH; Spielmann N; Mauch J; Weiss M
    J Intensive Care Med; 2013; 28(4):247-51. PubMed ID: 22833049
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Nitrogen insufflation decreases PVC endotracheal tube cuff flammability during CO2 laser surgery.
    Sosis M
    Can J Anaesth; 1990 May; 37(4 Pt 2):S136. PubMed ID: 2361263
    [No Abstract]   [Full Text] [Related]  

  • 38. Difficult tracheal tube passage and subglottic airway injury during intubation with the GlideScope
    Su K; Gao X; Xue FS; Ding GN; Zhang Y; Tian M
    Anaesthesia; 2017 Apr; 72(4):504-511. PubMed ID: 27995626
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Impact of tracheal cuff shape on microaspiration of gastric contents in intubated critically ill patients: study protocol for a randomized controlled trial.
    Jaillette E; Brunin G; Girault C; Zerimech F; Chiche A; Broucqsault-Dedrie C; Fayolle C; Minacori F; Alves I; Barrailler S; Robriquet L; Tamion F; Delaporte E; Thellier D; Delcourte C; Duhamel A; Nseir S
    Trials; 2015 Sep; 16():429. PubMed ID: 26407612
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Incidence of malposition of polyvinylchloride and red rubber left-sided double-lumen tubes and clinical sequelae.
    Cohen E; Neustein SM; Goldofsky S; Camunas JL
    J Cardiothorac Vasc Anesth; 1995 Apr; 9(2):122-7. PubMed ID: 7780066
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.