These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
133 related articles for article (PubMed ID: 3400908)
21. Systematic error of cardiac output measured by bolus thermodilution with a pulmonary artery catheter compared with that measured by an aortic flow probe in a pig model. Yang XX; Critchley LA; Rowlands DK; Fang Z; Huang L J Cardiothorac Vasc Anesth; 2013 Dec; 27(6):1133-9. PubMed ID: 24035141 [TBL] [Abstract][Full Text] [Related]
22. Thermodilution measurement of cardiac output in patients with low output: room-temperature versus iced injectate. Kiely M; Byers LA; Greenwood R; Carroll E; Carroll D Am J Crit Care; 1998 Nov; 7(6):436-8. PubMed ID: 9805117 [TBL] [Abstract][Full Text] [Related]
23. Direct measurement of cardiac output by gated equilibrium blood pool scintigraphy: validation of scintigraphic volume measurements by a nongeometric technique. Dehmer GJ; Firth BG; Lewis SE; Willerson JT; Hillis LD Am J Cardiol; 1981 May; 47(5):1061-7. PubMed ID: 7223652 [TBL] [Abstract][Full Text] [Related]
24. Multiple cardiac output measurements in man. Evaluation of a new closed-system thermodilution method. Stawicki JJ; Holford FD; Michelson EL; Josephson ME Chest; 1979 Aug; 76(2):193-7. PubMed ID: 456059 [TBL] [Abstract][Full Text] [Related]
25. Pulsed dye densitometry with two different sensor types for cardiac output measurement after cardiac surgery: a comparison with the thermodilution technique. Hofer CK; Bühlmann S; Klaghofer R; Genoni M; Zollinger A Acta Anaesthesiol Scand; 2004 May; 48(5):653-7. PubMed ID: 15101865 [TBL] [Abstract][Full Text] [Related]
26. In vitro determination of accuracy of cardiac output measurements by thermal dilution. Bilfinger TV; Lin CY; Anagnostopoulos CE J Surg Res; 1982 Nov; 33(5):409-14. PubMed ID: 7132327 [TBL] [Abstract][Full Text] [Related]
27. [Error analysis of the thermoindicator method for the determination of the heart minute volume]. Bilfinger TV Anasth Intensivther Notfallmed; 1982 Aug; 17(4):215-9. PubMed ID: 7137541 [TBL] [Abstract][Full Text] [Related]
29. Effect of injectate temperature and thermistor position on reproducibility of thermodilution cardiac output determinations. Williams JE; Pfau SE; Deckelbaum LI Chest; 1994 Sep; 106(3):895-8. PubMed ID: 8082374 [TBL] [Abstract][Full Text] [Related]
30. Importance of re-calibration time on pulse contour analysis agreement with thermodilution measurements of cardiac output: a retrospective analysis of intensive care unit patients. Scully CG; Gomatam S; Forrest S; Strauss DG J Clin Monit Comput; 2016 Oct; 30(5):577-86. PubMed ID: 26285740 [TBL] [Abstract][Full Text] [Related]
31. Ventilation, thermal noise, and errors in cardiac output measurements after cardiopulmonary bypass. Latson TW; Whitten CW; O'Flaherty D Anesthesiology; 1993 Dec; 79(6):1233-43. PubMed ID: 8267199 [TBL] [Abstract][Full Text] [Related]
32. Comparison of cardiac output determined by bioimpedance, thermodilution, and the Fick method. Engoren M; Barbee D Am J Crit Care; 2005 Jan; 14(1):40-5. PubMed ID: 15608107 [TBL] [Abstract][Full Text] [Related]
33. A comparison of methods of cardiac output measurement. Woog RH; McWilliam DB Anaesth Intensive Care; 1983 May; 11(2):141-6. PubMed ID: 6346941 [TBL] [Abstract][Full Text] [Related]
34. Issues in methods and measurement of thermodilution cardiac output. Sommers MS; Woods SL; Courtade MA Nurs Res; 1993; 42(4):228-33. PubMed ID: 8337161 [TBL] [Abstract][Full Text] [Related]
35. Accuracy of Cardiac Output by Nine Different Pulse Contour Algorithms in Cardiac Surgery Patients: A Comparison with Transpulmonary Thermodilution. Broch O; Bein B; Gruenewald M; Masing S; Huenges K; Haneya A; Steinfath M; Renner J Biomed Res Int; 2016; 2016():3468015. PubMed ID: 28116294 [No Abstract] [Full Text] [Related]
36. Right atrial effects on right ventricular ejection fraction derived from thermodilution measurements. Santamore WP; Gefen N; Avramovich A; Berger P; Kashem A; Barnea O J Cardiothorac Vasc Anesth; 2007 Oct; 21(5):644-9. PubMed ID: 17905267 [TBL] [Abstract][Full Text] [Related]
37. Noninvasive continuous cardiac output by the Nexfin before and after preload-modifying maneuvers: a comparison with intermittent thermodilution cardiac output. Bubenek-Turconi SI; Craciun M; Miclea I; Perel A Anesth Analg; 2013 Aug; 117(2):366-72. PubMed ID: 23757471 [TBL] [Abstract][Full Text] [Related]
38. Iced temperature injectate for thermodilution cardiac output determination causes minimal effects on cardiodynamics. Fang HK; Krahmer RL; Rypins EB; Law WR Crit Care Med; 1996 Mar; 24(3):495-500. PubMed ID: 8625640 [TBL] [Abstract][Full Text] [Related]
39. [Measurement of cardiac output with continuous thermodilution. b1 Clinical experience with the Intellicath-Vigilans system]. Procaccini B; Paladini A; Marfoglia C; Lattanzi FW; Miletti E; Gallo E; Clementi G Minerva Anestesiol; 1997 Nov; 63(11):365-70. PubMed ID: 9549279 [TBL] [Abstract][Full Text] [Related]