These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

168 related articles for article (PubMed ID: 340160)

  • 21. [Assessment of cardiac output by a non-invasive method. Estimation of partial pressure of CO2 by rebreathing of expired gas. Comparison with thermodilution].
    Chabrillat Y; Jammes Y; Zwirn P; Gérard R
    Arch Mal Coeur Vaiss; 1980 Jan; 73(1):107-13. PubMed ID: 6770776
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Cardiac output determined by the CO2 rebreathing method during arm exercise.
    Hopman MT; Oeseburg B; Binkhorst RA
    Clin Physiol; 1994 Jan; 14(1):37-46. PubMed ID: 8149708
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Determination of cardiac output at rest and during exercise by carbon dioxide rebreathing method in obstructive airway disease.
    Mahler DA; Matthay RA; Snyder PE; Neff RK; Loke J
    Am Rev Respir Dis; 1985 Jan; 131(1):73-8. PubMed ID: 3917635
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Comparison of rebreathing estimates with direct measurements of mixed venous PCO2 and PO2 in man.
    Denison D; Edwards RH; Jones G; Pope HM
    J Physiol; 1969 Jul; 203(1):75P-76P. PubMed ID: 5821923
    [No Abstract]   [Full Text] [Related]  

  • 25. Effect of independent changes in mixed-venous PCO2 or PO2 on cardiac output in anesthetized sheep.
    Shanley CJ; Shah NL; Overbeck MC; Kulkarni NB; Bartlett RH
    J Surg Res; 1997 Aug; 71(2):107-16. PubMed ID: 9299277
    [TBL] [Abstract][Full Text] [Related]  

  • 26. [A study of measuring cardiac output in patients during mechanical ventilation with CO2 rebreathing method].
    Bai CX; Niu SF; Xu FP
    Zhonghua Nei Ke Za Zhi; 1992 Apr; 31(4):220-2, 254-5. PubMed ID: 1425000
    [TBL] [Abstract][Full Text] [Related]  

  • 27. How to be less invasive.
    Powles AC; Campbell EJ
    Am J Med; 1979 Jul; 67(1):98-104. PubMed ID: 463922
    [TBL] [Abstract][Full Text] [Related]  

  • 28. An evaluation of exercise cardiac output using the CO2 rebreathing extrapolation technique.
    Rogers GG; van der Walt W
    Eur J Appl Physiol Occup Physiol; 1997; 75(5):431-4. PubMed ID: 9189731
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Comparison of methods to calculate cardiac output using the CO2 rebreathing method.
    Paterson DH; Cunningham DA
    Eur J Appl Physiol Occup Physiol; 1976 Aug; 35(3):223-30. PubMed ID: 782879
    [TBL] [Abstract][Full Text] [Related]  

  • 30. The reliability of the carbon dioxide-rebreathing, indirect Fick method of cardiac output determination in patients with pulmonary disease.
    Stewart RI; Lewis CM
    Clin Sci (Lond); 1983 Mar; 64(3):289-93. PubMed ID: 6401612
    [TBL] [Abstract][Full Text] [Related]  

  • 31. A new open-circuit method for estimating carbon dioxide tension in mixed venous blood.
    Al-Dulymi R; Hainsworth R
    Clin Sci Mol Med; 1977 Apr; 52(4):377-82. PubMed ID: 862333
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [Measurement of cardiac output by CO2 rebreathing technique. A study of reproducibility in the normal subject; application to cardiac insufficiency].
    Douard H; Blaquière C; Oysel N; Rougier P; Broustet JP
    Arch Mal Coeur Vaiss; 1993 Mar; 86(3):341-7. PubMed ID: 8215769
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Change in O2 uptake during rebreathing in hyperoxia in man.
    Shibuya I; Niizeki K; Uchida K
    Jpn J Physiol; 1986; 36(5):985-1000. PubMed ID: 3104639
    [TBL] [Abstract][Full Text] [Related]  

  • 34. A comparison of central venous-arterial and mixed venous-arterial carbon dioxide tension gradient in circulatory failure.
    Ho KM; Harding R; Chamberlain J
    Anaesth Intensive Care; 2007 Oct; 35(5):695-701. PubMed ID: 17933154
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Effects of reduced rebreathing time, in spontaneously breathing patients, on respiratory effort and accuracy in cardiac output measurement when using a partial carbon dioxide rebreathing technique: a prospective observational study.
    Tachibana K; Imanaka H; Takeuchi M; Nishida T; Takauchi Y; Nishimura M
    Crit Care; 2005 Oct; 9(5):R569-74. PubMed ID: 16277720
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Determination of mixed venous O2 and CO2 tensions and cardiac output by a rebreathing method.
    Cerretelli P; Cruz JC; Farhi LE; Rahn H
    Respir Physiol; 1966; 1(3):258-64. PubMed ID: 5968343
    [No Abstract]   [Full Text] [Related]  

  • 37. Determination of cardiac output based on breath-holding.
    Hoffstein V; Rebuck AS
    Crit Care Med; 1980 Nov; 8(11):671-4. PubMed ID: 6775875
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Estimation of blood gas contents from expired air under normal and pathologic conditions.
    Farrell EJ; Siegel JH
    Respir Physiol; 1976 May; 26(3):303-25. PubMed ID: 951535
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Cardiac output of Indian men by a non-invasive method the Indirect Fick Principle.
    Sharma JD; Saxena RK; Rastogi SK
    Indian J Physiol Pharmacol; 1977; 21(4):347-52. PubMed ID: 614284
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Deriving the arterial Po
    Prisk GK; West JB
    J Appl Physiol (1985); 2019 Oct; 127(4):1067-1074. PubMed ID: 31436512
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.