These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

187 related articles for article (PubMed ID: 34025792)

  • 41. Novel suture/suture-anchor fixation versus tension band wiring for olecranon fractures: A systematic review.
    Dogramatzis K; Kitridis D; Bekoulis T; Craig R
    Shoulder Elbow; 2023 Aug; 15(4):424-435. PubMed ID: 37538526
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Kirschner Wire Fixation with and without Tension Band Wiring for Treatment of Fracture of the Lateral Humeral Condyle in Children.
    Tomori Y; Nanno M; Takai S
    J Nippon Med Sch; 2020 Mar; 87(1):17-23. PubMed ID: 31611504
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Comparison of two surgical techniques for the treatment of transverse olecranon fractures: A finite element study.
    Civan O; Ugur L; Yildiz G
    Int J Med Robot; 2021 Aug; 17(4):e2265. PubMed ID: 33855772
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Comparison of Functional and Radiological Outcomes of Transverse Patellar Fractures Fixed with Tension Band Fixation Using Cannulated Screws and Kirschner Wires: A Prospective Randomized Study.
    Drolia N; Sinha S; Paneru SR; Kumar A; Jameel J; Kumar S; Shrestha B; Khanal GP
    Indian J Orthop; 2022 Mar; 56(3):369-376. PubMed ID: 35251499
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Intramedullary Cancellous Screw Fixation of Simple Olecranon Fractures.
    Oitment C; Koziarz A; Bozzo A; Johal H
    Strategies Trauma Limb Reconstr; 2019; 14(3):163-167. PubMed ID: 32742433
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Outcomes of olecranon fractures in adolescents: comparison of tension band wiring and Herbert screw fixations.
    Yang W; Zhang X; Sun D; Jin S; Chen J; Li Y
    Front Pediatr; 2023; 11():1269628. PubMed ID: 38274471
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Comparison of the efficacy of the tension band wiring with eyelet wire versus anatomical locking plate fixation for the treatment of displaced olecranon fractures.
    Shimura H; Nimura A; Fujita K; Kaburagi H
    J Orthop Surg (Hong Kong); 2021; 29(3):23094990211059231. PubMed ID: 34872400
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Biomechanical comparison of the new cross-locking intramedullary nail with tension band wiring for transverse olecranon fractures.
    Liang C; Li CY; Qin XS; Wang G; Duan K; Lu XB
    Injury; 2023 Apr; 54 Suppl 2():S95-S100. PubMed ID: 35871853
    [TBL] [Abstract][Full Text] [Related]  

  • 49. There is no difference in the complication or re-operation rates between tension band wiring and locking plate fixation for olecranon fractures. The findings of a multicentre study.
    Oputa TJ; Plastow R; Kennedy J; Jain N;
    Arch Orthop Trauma Surg; 2022 Nov; 142(11):3341-3345. PubMed ID: 34581860
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Efficacy comparison of Kirschner-wire tension band and anchor loop plate in treatment of olecranon fracture.
    Du B; Su Y; Ma T; Ji S; Lu Y; Zhang K; Li Z; Li M
    Front Bioeng Biotechnol; 2023; 11():1203244. PubMed ID: 37724095
    [No Abstract]   [Full Text] [Related]  

  • 51. Factors Affecting the Range of Motion of the Elbow after Open Reduction of Olecranon Fractures.
    Fujihara Y; Ota H; Watanabe K
    J Hand Surg Asian Pac Vol; 2021 Mar; 26(1):60-64. PubMed ID: 33559569
    [No Abstract]   [Full Text] [Related]  

  • 52. Plate Versus Tension-Band Wire Fixation for Olecranon Fractures: A Prospective Randomized Trial.
    Duckworth AD; Clement ND; White TO; Court-Brown CM; McQueen MM
    J Bone Joint Surg Am; 2017 Aug; 99(15):1261-1273. PubMed ID: 28763412
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Cerclage fixation without K-wires is associated with fewer complications and reoperations compared with tension band wiring in stable displaced olecranon fractures in elderly patients.
    Wenger D; Cornefjord G; Rogmark C
    Arch Orthop Trauma Surg; 2022 Oct; 142(10):2669-2676. PubMed ID: 34236459
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Comparative Analysis of Clinical Effects of the Cable-Pin System and Kirschner Wire Tension Band (TBW) Internal Fixation in the Treatment of the Olecranon Fracture.
    Rao C; Hu H; Tan R
    Contrast Media Mol Imaging; 2022; 2022():3073121. PubMed ID: 35800232
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Biomechanical comparison of bi- and tricortical k-wire fixation in tension band wiring osteosynthesis.
    Nowotny J; Bischoff F; Ahlfeld T; Goronzy J; Tille E; Nimtschke U; Biewener A
    Eur J Med Res; 2019 Oct; 24(1):33. PubMed ID: 31594540
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Surgical Treatment for Simple Isolated and Displaced Olecranon Fractures: Comparison between Plate and Tension Band Wire Fixation.
    Giardina SMC; Testa G; Cuffaro ER; Castiglione MD; Sapienza M; Caldaci A; Cosentino P; Raffa A; Pavone V
    J Clin Med; 2024 Mar; 13(6):. PubMed ID: 38542038
    [No Abstract]   [Full Text] [Related]  

  • 57. Surgical Management for Olecranon Fractures in Adults: A Systematic Review and Meta-analysis.
    Koziarz A; Woolnough T; Oitment C; Nath S; Johal H
    Orthopedics; 2019 Mar; 42(2):75-82. PubMed ID: 30810755
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Locked Tension Band Wiring for Mayo IIA Olecranon Fractures: Modified Surgical Technique and Retrospective Comparative Study of Clinical Outcomes and Cost-effectiveness with Locking Plate.
    Kuwahara Y; Takegami Y; Mitsuya S; Tokutake K; Yamauchi K; Imagama S
    J Hand Surg Asian Pac Vol; 2023 Apr; 28(2):205-213. PubMed ID: 37120308
    [No Abstract]   [Full Text] [Related]  

  • 59. Tension-band wiring of displaced stable olecranon fractures with Eyelet-pins in the elderly: A series of 17 cases.
    Tsujino S; Tsujino A; Matsubara M
    Orthop Traumatol Surg Res; 2021 Dec; 107(8):103076. PubMed ID: 34563734
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Locked Tension Band Wiring: A Modified Technique for Olecranon Fractures-A Multicenter Study Comparing Clinical Outcomes and Complications with Conventional Methods.
    Kuwahara Y; Takegami Y; Mitsuya S; Tokutake K; Yamauchi K; Imagama S
    Indian J Orthop; 2023 Dec; 57(12):2024-2030. PubMed ID: 38009177
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.