BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

264 related articles for article (PubMed ID: 34028053)

  • 1. Cone beam CT based validation of neural network generated synthetic CTs for radiotherapy in the head region.
    Irmak S; Zimmermann L; Georg D; Kuess P; Lechner W
    Med Phys; 2021 Aug; 48(8):4560-4571. PubMed ID: 34028053
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of the suitability of CBCT- and MR-based synthetic CTs for daily adaptive proton therapy in head and neck patients.
    Thummerer A; de Jong BA; Zaffino P; Meijers A; Marmitt GG; Seco J; Steenbakkers RJHM; Langendijk JA; Both S; Spadea MF; Knopf AC
    Phys Med Biol; 2020 Dec; 65(23):235036. PubMed ID: 33179874
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of CBCT based synthetic CT methods suitable for proton dose calculations in adaptive proton therapy.
    Thummerer A; Zaffino P; Meijers A; Marmitt GG; Seco J; Steenbakkers RJHM; Langendijk JA; Both S; Spadea MF; Knopf AC
    Phys Med Biol; 2020 Apr; 65(9):095002. PubMed ID: 32143207
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dosimetric evaluation of synthetic CT for head and neck radiotherapy generated by a patch-based three-dimensional convolutional neural network.
    Dinkla AM; Florkow MC; Maspero M; Savenije MHF; Zijlstra F; Doornaert PAH; van Stralen M; Philippens MEP; van den Berg CAT; Seevinck PR
    Med Phys; 2019 Sep; 46(9):4095-4104. PubMed ID: 31206701
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Cone Beam CT (CBCT) Based Synthetic CT Generation Using Deep Learning Methods for Dose Calculation of Nasopharyngeal Carcinoma Radiotherapy.
    Xue X; Ding Y; Shi J; Hao X; Li X; Li D; Wu Y; An H; Jiang M; Wei W; Wang X
    Technol Cancer Res Treat; 2021; 20():15330338211062415. PubMed ID: 34851204
    [No Abstract]   [Full Text] [Related]  

  • 6. Deep learning-based 4D-synthetic CTs from sparse-view CBCTs for dose calculations in adaptive proton therapy.
    Thummerer A; Seller Oria C; Zaffino P; Visser S; Meijers A; Guterres Marmitt G; Wijsman R; Seco J; Langendijk JA; Knopf AC; Spadea MF; Both S
    Med Phys; 2022 Nov; 49(11):6824-6839. PubMed ID: 35982630
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Clinical suitability of deep learning based synthetic CTs for adaptive proton therapy of lung cancer.
    Thummerer A; Seller Oria C; Zaffino P; Meijers A; Guterres Marmitt G; Wijsman R; Seco J; Langendijk JA; Knopf AC; Spadea MF; Both S
    Med Phys; 2021 Dec; 48(12):7673-7684. PubMed ID: 34725829
    [TBL] [Abstract][Full Text] [Related]  

  • 8. CBCT-based synthetic CT generation using deep-attention cycleGAN for pancreatic adaptive radiotherapy.
    Liu Y; Lei Y; Wang T; Fu Y; Tang X; Curran WJ; Liu T; Patel P; Yang X
    Med Phys; 2020 Jun; 47(6):2472-2483. PubMed ID: 32141618
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Dosimetric study on learning-based cone-beam CT correction in adaptive radiation therapy.
    Wang T; Lei Y; Manohar N; Tian S; Jani AB; Shu HK; Higgins K; Dhabaan A; Patel P; Tang X; Liu T; Curran WJ; Yang X
    Med Dosim; 2019 Winter; 44(4):e71-e79. PubMed ID: 30948341
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluating the Hounsfield unit assignment and dose differences between CT-based standard and deep learning-based synthetic CT images for MRI-only radiation therapy of the head and neck.
    Singhrao K; Dugan CL; Calvin C; Pelayo L; Yom SS; Chan JW; Scholey JE; Singer L
    J Appl Clin Med Phys; 2024 Jan; 25(1):e14239. PubMed ID: 38128040
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Generating synthetic CT from low-dose cone-beam CT by using generative adversarial networks for adaptive radiotherapy.
    Gao L; Xie K; Wu X; Lu Z; Li C; Sun J; Lin T; Sui J; Ni X
    Radiat Oncol; 2021 Oct; 16(1):202. PubMed ID: 34649572
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Dosimetric evaluation of cone-beam CT-based synthetic CTs in pediatric patients undergoing intensity-modulated proton therapy.
    Sheikh K; Liu D; Li H; Acharya S; Ladra MM; Hrinivich WT
    J Appl Clin Med Phys; 2022 Jun; 23(6):e13604. PubMed ID: 35413144
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Deep learning approaches using 2D and 3D convolutional neural networks for generating male pelvic synthetic computed tomography from magnetic resonance imaging.
    Fu J; Yang Y; Singhrao K; Ruan D; Chu FI; Low DA; Lewis JH
    Med Phys; 2019 Sep; 46(9):3788-3798. PubMed ID: 31220353
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Cone beam CT for QA of synthetic CT in MRI only for prostate patients.
    Palmér E; Persson E; Ambolt P; Gustafsson C; Gunnlaugsson A; Olsson LE
    J Appl Clin Med Phys; 2018 Nov; 19(6):44-52. PubMed ID: 30182461
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Technical note: Evaluation of deep learning based synthetic CTs clinical readiness for dose and NTCP driven head and neck adaptive proton therapy.
    de Koster RJC; Thummerer A; Scandurra D; Langendijk JA; Both S
    Med Phys; 2023 Dec; 50(12):8023-8033. PubMed ID: 37831597
    [TBL] [Abstract][Full Text] [Related]  

  • 16. MR-Only Brain Radiation Therapy: Dosimetric Evaluation of Synthetic CTs Generated by a Dilated Convolutional Neural Network.
    Dinkla AM; Wolterink JM; Maspero M; Savenije MHF; Verhoeff JJC; Seravalli E; Išgum I; Seevinck PR; van den Berg CAT
    Int J Radiat Oncol Biol Phys; 2018 Nov; 102(4):801-812. PubMed ID: 30108005
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Feasibility of MRI-only treatment planning for proton therapy in brain and prostate cancers: Dose calculation accuracy in substitute CT images.
    Koivula L; Wee L; Korhonen J
    Med Phys; 2016 Aug; 43(8):4634. PubMed ID: 27487880
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of a cycle-generative adversarial network-based cone-beam CT to synthetic CT conversion algorithm for adaptive radiation therapy.
    Eckl M; Hoppen L; Sarria GR; Boda-Heggemann J; Simeonova-Chergou A; Steil V; Giordano FA; Fleckenstein J
    Phys Med; 2020 Dec; 80():308-316. PubMed ID: 33246190
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Dosimetric comparison of deformable image registration and synthetic CT generation based on CBCT images for organs at risk in cervical cancer radiotherapy.
    Chang Y; Liang Y; Yang B; Qiu J; Pei X; Xu XG
    Radiat Oncol; 2023 Jan; 18(1):3. PubMed ID: 36604687
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Improving CBCT quality to CT level using deep learning with generative adversarial network.
    Zhang Y; Yue N; Su MY; Liu B; Ding Y; Zhou Y; Wang H; Kuang Y; Nie K
    Med Phys; 2021 Jun; 48(6):2816-2826. PubMed ID: 33259647
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.