These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

128 related articles for article (PubMed ID: 34030142)

  • 1. Quantitative analysis of bone microvasculature in a mouse model using the monogenic signal phase asymmetry and marker-controlled watershed.
    Xu H; Langer M; Peyrin F
    Phys Med Biol; 2021 Jun; 66(12):. PubMed ID: 34030142
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Improved middle-ear soft-tissue visualization using synchrotron radiation phase-contrast imaging.
    Elfarnawany M; Rohani SA; Ghomashchi S; Allen DG; Zhu N; Agrawal SK; Ladak HM
    Hear Res; 2017 Oct; 354():1-8. PubMed ID: 28822316
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Microvascular imaging of the unstained human superior colliculus using synchrotron-radiation phase-contrast microtomography.
    Lee JY; Mack AF; Shiozawa T; Longo R; Tromba G; Scheffler K; Hagberg GE
    Sci Rep; 2022 Jun; 12(1):9238. PubMed ID: 35655082
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A comparative study of automatic thresholding approaches for 3D x-ray microtomography of trabecular bone.
    Gómez W; Sales E; Lopes RT; Pereira WC
    Med Phys; 2013 Sep; 40(9):091903. PubMed ID: 24007154
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A vessel segmentation method for multi-modality angiographic images based on multi-scale filtering and statistical models.
    Lu P; Xia J; Li Z; Xiong J; Yang J; Zhou S; Wang L; Chen M; Wang C
    Biomed Eng Online; 2016 Nov; 15(1):120. PubMed ID: 27825346
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Characterization and quantification of angiogenesis in rheumatoid arthritis in a mouse model using μCT.
    Gayetskyy S; Museyko O; Käßer J; Hess A; Schett G; Engelke K
    BMC Musculoskelet Disord; 2014 Sep; 15():298. PubMed ID: 25194942
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Performance evaluation of segmentation methods for assessing the lens of the frog Thoropa miliaris from synchrotron-based phase-contrast micro-CT images.
    Paiva K; Meneses AAM; Barcellos R; Moura MSDS; Mendes G; Fidalgo G; Sena G; Colaço G; Silva HR; Braz D; Colaço MV; Barroso RC
    Phys Med; 2022 Feb; 94():43-52. PubMed ID: 34995977
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of vessel enhancement algorithms applied to time-of-flight MRA images for cerebrovascular segmentation.
    Phellan R; Forkert ND
    Med Phys; 2017 Nov; 44(11):5901-5915. PubMed ID: 28881037
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Automatic segmentation method for bone and blood vessel in murine hindlimb.
    Zhao F; Liang J; Chen D; Wang C; Yang X; Chen X; Cao F
    Med Phys; 2015 Jul; 42(7):4043-54. PubMed ID: 26133605
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Quantitative Analysis of Bone, Blood Vessels, and Metastases in Mice Tibiae Using Synchrotron Radiation Micro-Computed Tomography.
    Xu H; Langer M
    Cancers (Basel); 2023 Nov; 15(23):. PubMed ID: 38067313
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effects of object-to-detector distance and beam energy on synchrotron radiation phase-contrast imaging of implanted cochleae.
    Rohani SA; Iyaniwura JE; Zhu N; Agrawal SK; Ladak HM
    J Microsc; 2019 Feb; 273(2):127-134. PubMed ID: 30431166
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Three Dimensional Quantification of Microarchitecture and Vessel Regeneration by Synchrotron Radiation Microcomputed Tomography in a Rat Model of Spinal Cord Injury.
    Cao Y; Zhou Y; Ni S; Wu T; Li P; Liao S; Hu J; Lu H
    J Neurotrauma; 2017 Mar; 34(6):1187-1199. PubMed ID: 27676128
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A computational pipeline for quantification of pulmonary infections in small animal models using serial PET-CT imaging.
    Bagci U; Foster B; Miller-Jaster K; Luna B; Dey B; Bishai WR; Jonsson CB; Jain S; Mollura DJ
    EJNMMI Res; 2013 Jul; 3(1):55. PubMed ID: 23879987
    [TBL] [Abstract][Full Text] [Related]  

  • 14. 3D-imaging and quantitative assessment for size-related penetration of HfO
    Wang J; Zhang T; Liao Y; Chen W; Liang S; Xu S; Fang H; Wang M; Zheng L; Gu Z; Zhang Z; Wang B; Bi Y; Feng W
    Anal Chim Acta; 2023 Jul; 1266():341352. PubMed ID: 37244662
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Quantitative investigation of bone microvascularization from 3D synchrotron micro-computed tomography in a rat model.
    Langer M; Prisby R; Peter Z; Boistel R; Lafage-Proust MH; Peyrin F
    Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():1004-7. PubMed ID: 19964493
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Subtraction micro-computed tomography of angiogenesis and osteogenesis during bone repair using synchrotron radiation with a novel contrast agent.
    Matsumoto T; Goto D; Sato S
    Lab Invest; 2013 Sep; 93(9):1054-63. PubMed ID: 23835738
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Assessment of bone tissue mineralization by conventional x-ray microcomputed tomography: comparison with synchrotron radiation microcomputed tomography and ash measurements.
    Kazakia GJ; Burghardt AJ; Cheung S; Majumdar S
    Med Phys; 2008 Jul; 35(7):3170-9. PubMed ID: 18697542
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Dose fractionation in synchrotron radiation x-ray phase micro-tomography.
    Frachon T; Weber L; Hesse B; Rit S; Dong P; Olivier C; Peyrin F; Langer M
    Phys Med Biol; 2015 Oct; 60(19):7543-66. PubMed ID: 26371834
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Fully automated segmentation of a hip joint using the patient-specific optimal thresholding and watershed algorithm.
    Kim JJ; Nam J; Jang IG
    Comput Methods Programs Biomed; 2018 Feb; 154():161-171. PubMed ID: 29249340
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of Synchrotron Radiation-based Propagation Phase Contrast Imaging and Conventional Micro-computed Tomography for Assessing Intervertebral Discs and Endplates in a Murine Model.
    Hu J; Ni S; Cao Y; Wang X; Liao S; Lu H
    Spine (Phila Pa 1976); 2017 Aug; 42(15):E883-E889. PubMed ID: 28187077
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.