BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

248 related articles for article (PubMed ID: 34035192)

  • 1. Crystal surface and reflector optimization for the SiPM-based dual-ended readout TOF-DOI PET detector.
    Kang HG; Yamaya T; Han YB; Song SH; Ko GB; Lee JS; Hong SJ
    Biomed Phys Eng Express; 2020 Nov; 6(6):. PubMed ID: 34035192
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Depth-of-interaction positron emission tomography detector with 45° tilted silicon photomultipliers using dual-ended signal readout.
    Seo M; Park H; Lee S; Ko GB; Lee JS
    Med Phys; 2023 Jul; 50(7):4112-4121. PubMed ID: 36907664
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Development of depth encoding small animal PET detectors using dual-ended readout of pixelated scintillator arrays with SiPMs.
    Kuang Z; Sang Z; Wang X; Fu X; Ren N; Zhang X; Zheng Y; Yang Q; Hu Z; Du J; Liang D; Liu X; Zheng H; Yang Y
    Med Phys; 2018 Feb; 45(2):613-621. PubMed ID: 29222959
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Study of optical reflectors for a 100ps coincidence time resolution TOF-PET detector design.
    Gonzalez-Montoro A; Pourashraf S; Lee MS; Cates JW; Levin CS
    Biomed Phys Eng Express; 2021 Sep; 7(6):. PubMed ID: 34488203
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Performance of long rectangular semi-monolithic scintillator PET detectors.
    Zhang X; Wang X; Ren N; Hu B; Ding B; Kuang Z; Wu S; Sang Z; Hu Z; Du J; Liang D; Liu X; Zheng H; Yang Y
    Med Phys; 2019 Apr; 46(4):1608-1619. PubMed ID: 30723932
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Depth-of-interaction study of a dual-readout detector based on TOFPET2 application-specific integrated circuit.
    Li M; Abbaszadeh S
    Phys Med Biol; 2019 Sep; 64(17):175008. PubMed ID: 31382253
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Depth-encoding using optical photon TOF in a prism-PET detector with tapered crystals.
    Zeng X; LaBella A; Wang Z; Li Y; Tan W; Goldan AH
    Med Phys; 2024 Apr; ():. PubMed ID: 38682574
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effects of reflector and crystal surface on the performance of a depth-encoding PET detector with dual-ended readout.
    Ren S; Yang Y; Cherry SR
    Med Phys; 2014 Jul; 41(7):072503. PubMed ID: 24989406
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Low power implementation of high frequency SiPM readout for Cherenkov and scintillation detectors in TOF-PET.
    Cates JW; Choong WS
    Phys Med Biol; 2022 Sep; 67(19):. PubMed ID: 35961297
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Pushing the limit of BGO-based dual-ended Cherenkov PET detectors through photon transit time correction.
    Yi M; Ko GB; Lee JS
    Phys Med Biol; 2024 Jan; 69(2):. PubMed ID: 38091614
    [No Abstract]   [Full Text] [Related]  

  • 11. Side readout of long scintillation crystal elements with digital SiPM for TOF-DOI PET.
    Yeom JY; Vinke R; Levin CS
    Med Phys; 2014 Dec; 41(12):122501. PubMed ID: 25471979
    [TBL] [Abstract][Full Text] [Related]  

  • 12. High resolution detectors for whole-body PET scanners by using dual-ended readout.
    Liu Z; Niu M; Kuang Z; Ren N; Wu S; Cong L; Wang X; Sang Z; Williams C; Yang Y
    EJNMMI Phys; 2022 Apr; 9(1):29. PubMed ID: 35445890
    [TBL] [Abstract][Full Text] [Related]  

  • 13. An edge-readout, multilayer detector for positron emission tomography.
    Li X; Ruiz-Gonzalez M; Furenlid LR
    Med Phys; 2018 Jun; 45(6):2425-2438. PubMed ID: 29635734
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Performance comparison of dual-ended readout depth-encoding PET detectors based on BGO and LYSO crystals.
    Du J; Ariño-Estrada G; Bai X; Cherry SR
    Phys Med Biol; 2020 Nov; 65(23):. PubMed ID: 33086214
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A depth-of-interaction encoding PET detector module with dual-ended readout using large-area silicon photomultiplier arrays.
    Du J; Bai X; Cherry SR
    Phys Med Biol; 2018 Dec; 63(24):245019. PubMed ID: 30523925
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Optical Simulation and Experimental Assessment with Time-Walk Correction of TOF-PET Detectors with Multi-Ended Readouts.
    Xie S; Zhu Z; Zhang X; Xie Q; Yu H; Zhang Y; Xu J; Peng Q
    Sensors (Basel); 2021 Jul; 21(14):. PubMed ID: 34300421
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Tracking the same fast-LGSO crystals by changing surface treatments for better coincidence timing resolution in PET.
    Kiyokawa M; Kang HG; Yamaya T
    Biomed Phys Eng Express; 2023 Feb; 9(2):. PubMed ID: 36689772
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Performance of a depth encoding PET detector module using light sharing and single-ended readout with SiPMs.
    Kuang Z; Yang Q; Wang X; Fu X; Ren N; Wu S; Zhang C; Zhao B; Sang Z; Hu Z; Du J; Liang D; Liu X; Zheng H; Yang Y
    Phys Med Biol; 2019 Apr; 64(8):085012. PubMed ID: 30893674
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A time-based double-sided readout concept of 100 mm LYSO:Ce,Ca fibres for future axial TOF-PET.
    Weindel K; Nadig V; Herweg K; Schulz V; Gundacker S
    EJNMMI Phys; 2023 Jul; 10(1):43. PubMed ID: 37450099
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A novel depth-of-interaction block detector for positron emission tomography using a dichotomous orthogonal symmetry decoding concept.
    Zhang Y; Yan H; Baghaei H; Wong WH
    Phys Med Biol; 2016 Feb; 61(4):1608-33. PubMed ID: 26836144
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.