These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

126 related articles for article (PubMed ID: 3403601)

  • 1. The interior of the flexor tendon sheath of the finger. The functional significance of its structure.
    Amis AA; Jones MM
    J Bone Joint Surg Br; 1988 Aug; 70(4):583-7. PubMed ID: 3403601
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The fibrous flexor sheaths of the fingers.
    Jones MM; Amis AA
    J Anat; 1988 Feb; 156():185-96. PubMed ID: 3417546
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Surface markers for locating the pulleys and flexor tendon anatomy in the palm and fingers with reference to minimally invasive incisions.
    Gordon JA; Stone L; Gordon L
    J Hand Surg Am; 2012 May; 37(5):913-8. PubMed ID: 22365712
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Palmar and digital flexor tendon pulleys.
    Doyle JR
    Clin Orthop Relat Res; 2001 Feb; (383):84-96. PubMed ID: 11210973
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effect of A3 pulley and adjacent sheath integrity on tendon excursion and bowstringing.
    Tang JB; Xie RG
    J Hand Surg Am; 2001 Sep; 26(5):855-61. PubMed ID: 11561238
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Pulley system in the fingers: normal anatomy and simulated lesions in cadavers at MR imaging, CT, and US with and without contrast material distention of the tendon sheath.
    Hauger O; Chung CB; Lektrakul N; Botte MJ; Trudell D; Boutin RD; Resnick D
    Radiology; 2000 Oct; 217(1):201-12. PubMed ID: 11012445
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Anatomy of the finger flexor tendon sheath and pulley system.
    Doyle JR
    J Hand Surg Am; 1988 Jul; 13(4):473-84. PubMed ID: 3418049
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The mechanical role of the digital fibrous sheath: application to reconstructive surgery of the flexor tendons.
    Delattre JF; Ducasse A; Flament JB; Kénési C
    Anat Clin; 1983; 5(3):187-97. PubMed ID: 6671063
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Digital flexor sheath: repair and reconstruction of the annular pulleys and membranous sheath.
    Seiler JG; Leversedge FJ
    J South Orthop Assoc; 2000; 9(2):81-90. PubMed ID: 10901645
    [TBL] [Abstract][Full Text] [Related]  

  • 10. What is new in flexor tendon pulleys and the gaps between them in triphalangeal fingers of the hand?
    De Las Heras J; Simón de Blas C; Salaberri GJ; Krompas I; Olewnik L; Quinones S; García-Elías M; Sanudo JR; Aragonés P
    J Anat; 2024 Jul; 245(1):12-26. PubMed ID: 38419199
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The double sheath system and tendon gliding in zone 2C.
    Tang JB
    J Hand Surg Br; 1995 Jun; 20(3):281-5. PubMed ID: 7561397
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Flexor tendon grafts for pulley reconstruction - Morphological aspects.
    Fritz T; Ducommun P; Pohlemann T; Calcagni M; Tschernig T; Menger MD; Metzger W; Frueh FS
    Ann Anat; 2020 Sep; 231():151550. PubMed ID: 32512200
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Functional anatomy of the vagina fibrosa of the flexors of the fingers.
    Hoving EW; Hillen B
    J Hand Surg Br; 1989 Feb; 14(1):99-101. PubMed ID: 2926232
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Digital flexor tendon sheath: an anatomic study.
    Strauch B; de Moura W
    J Hand Surg Am; 1985 Nov; 10(6 Pt 1):785-9. PubMed ID: 4078260
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Flexor pulley system: anatomy, injury, and management.
    Zafonte B; Rendulic D; Szabo RM
    J Hand Surg Am; 2014 Dec; 39(12):2525-32; quiz 2533. PubMed ID: 25459958
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The flexor synovial sheath anatomy of the little finger: a macroscopic study.
    Phillips CS; Falender R; Mass DP
    J Hand Surg Am; 1995 Jul; 20(4):636-41. PubMed ID: 7594293
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Feasibility of partial A2 and A4 pulley excision: residual pulley strength.
    Mitsionis G; Fischer KJ; Bastidas JA; Grewal R; Pfaeffle HJ; Tomaino MM
    J Hand Surg Br; 2000 Feb; 25(1):90-4. PubMed ID: 10763733
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Connective tissue reinforcing structures of the digital tendon sheaths of the human hand].
    Knott C; Schmidt HM
    Gegenbaurs Morphol Jahrb; 1986; 132(1):1-28. PubMed ID: 3710108
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The vascularization and structure of the human digital tendon sheath as related to flexor tendon function. An angiographic and histological study.
    Lundborg G; Myrhage R
    Scand J Plast Reconstr Surg; 1977; 11(3):195-203. PubMed ID: 609902
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Anatomy of the flexor tendon sheath and pulley system: a current review.
    Doyle JR
    J Hand Surg Am; 1989 Mar; 14(2 Pt 2):349-51. PubMed ID: 2732428
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.