134 related articles for article (PubMed ID: 3403613)
1. Anterior cruciate ligament replacement. Biocompatibility and biomechanics of polyester and carbon fibre in rabbits.
Amis AA; Kempson SA; Campbell JR; Miller JH
J Bone Joint Surg Br; 1988 Aug; 70(4):628-34. PubMed ID: 3403613
[TBL] [Abstract][Full Text] [Related]
2. Prosthetic anterior cruciate ligaments in the rabbit. A comparison of four types of replacement.
Thomas NP; Turner IG; Jones CB
J Bone Joint Surg Br; 1987 Mar; 69(2):312-6. PubMed ID: 2950103
[TBL] [Abstract][Full Text] [Related]
3. [Carbon band implants in animal experiments. Light and transmission electron microscopy studies of biocompatibility].
Rohe K; Braun A; Cotta H
Z Orthop Ihre Grenzgeb; 1986; 124(5):569-77. PubMed ID: 3544554
[TBL] [Abstract][Full Text] [Related]
4. The effect of continuous passive motion on knee ligament reconstruction with carbon fibre. An experimental investigation.
Zarnett R; Velazquez R; Salter RB
J Bone Joint Surg Br; 1991 Jan; 73(1):47-52. PubMed ID: 1991774
[TBL] [Abstract][Full Text] [Related]
5. Anterior cruciate ligament replacement. Knee stability and the effects of implants.
Amis AA
J Bone Joint Surg Br; 1989 Nov; 71(5):819-24. PubMed ID: 2584254
[TBL] [Abstract][Full Text] [Related]
6. [Experimental evaluation of using polyester prosthesis of various textures for alloplasty in cruciate ligaments of the knee].
Urban J
Polim Med; 1993; 23(1-2):55-67. PubMed ID: 8415288
[TBL] [Abstract][Full Text] [Related]
7. Anterior cruciate ligament replacement with polyester fibre. A long-term study of tissue reactions and joint stability in sheep.
Amis AA; Camburn M; Kempson SA; Radford WJ; Stead AC
J Bone Joint Surg Br; 1992 Jul; 74(4):605-13. PubMed ID: 1624524
[TBL] [Abstract][Full Text] [Related]
8. Development of the Apex polyester fibre cruciate ligament implant.
Amis AA
Clin Mater; 1994; 15(1):51-60. PubMed ID: 10172023
[TBL] [Abstract][Full Text] [Related]
9. The biological reaction of the tissues to carbon fibre ligament prosthesis in sheep-knees.
Neugebauer R; Claes L
Aktuelle Probl Chir Orthop; 1983; 26():96-100. PubMed ID: 6136238
[TBL] [Abstract][Full Text] [Related]
10. [Cruciate ligament replacement--current status. Carbon fiber implants].
Helbing G; Burri C; Neugebauer R
Unfallchirurgie; 1985 Oct; 11(5):259-63. PubMed ID: 4071839
[TBL] [Abstract][Full Text] [Related]
11. The combined anterior cruciate and medial collateral ligament replacement by various materials: a comparative animal study.
Claes L; Dürselen L; Kiefer H; Mohr W
J Biomed Mater Res; 1987 Dec; 21(A3 Suppl):319-43. PubMed ID: 3429469
[TBL] [Abstract][Full Text] [Related]
12. [Replacement of the anterior cruciate ligament by carbon fibers. An experimental study].
Goutallier D; Bercovy M; Blanquaert D; Voisin MC; Gaudichet A; Trevisan D; Geiger D; Rouveix B
Rev Chir Orthop Reparatrice Appar Mot; 1983; 69(3):187-94. PubMed ID: 6224269
[TBL] [Abstract][Full Text] [Related]
13. Biocompatibility of carbon fibre and carbon fibre microparticles.
Wolter D
Aktuelle Probl Chir Orthop; 1983; 26():28-36. PubMed ID: 6136228
[TBL] [Abstract][Full Text] [Related]
14. Comparative analysis of four types of synthetic anterior cruciate ligament replacement in the goat: in vivo histological and mechanical findings.
Turner IG; Thomas NP
Biomaterials; 1990 Jul; 11(5):321-9. PubMed ID: 2144774
[TBL] [Abstract][Full Text] [Related]
15. In vivo and in vitro investigation of the long-term behavior and fatigue strength of carbon fiber ligament replacement.
Claes L; Neugebauer R
Clin Orthop Relat Res; 1985 Jun; (196):99-111. PubMed ID: 3995839
[TBL] [Abstract][Full Text] [Related]
16. [Animal experimental studies on temporary intra-articular knee joint stabilization by a synthetic ligament (polyester-silicone)].
Wirth CJ
Aktuelle Probl Chir Orthop; 1983; 25():70-5. PubMed ID: 6136213
[No Abstract] [Full Text] [Related]
17. Strength of carbon and polyester fibre tendon replacements. Variation after operation in rabbits.
Amis AA; Campbell JR; Miller JH
J Bone Joint Surg Br; 1985 Nov; 67(5):829-34. PubMed ID: 4055886
[TBL] [Abstract][Full Text] [Related]
18. Replacement of the medial collateral ligament with polypropylene mesh or a polyester suture in dogs.
Robello GT; Aron DN; Foutz TL; Rowland GN
Vet Surg; 1992; 21(6):467-74. PubMed ID: 1455651
[TBL] [Abstract][Full Text] [Related]
19. Can carbon fiber implants substitute for collateral ligament?
Gleason TF; Barmada R; Ghosh L
Clin Orthop Relat Res; 1984 Dec; (191):274-80. PubMed ID: 6499320
[TBL] [Abstract][Full Text] [Related]
20. Histological response to carbon fibre.
Mendes DG; Angel D; Grishkan A; Boss J
J Bone Joint Surg Br; 1985 Aug; 67(4):645-9. PubMed ID: 4030868
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]