These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

146 related articles for article (PubMed ID: 34037533)

  • 21. Assessment of Regional Diagnostic Reference Levels in Dental Radiography in Tamil Nadu.
    Jose A; Kumar AS; Govindarajan KN; Sharma SD
    J Med Phys; 2022; 47(1):86-92. PubMed ID: 35548027
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Assessment of different computational models for generation of x-ray spectra in diagnostic radiology and mammography.
    Ay MR; Sarkar S; Shahriari M; Sardari D; Zaidi H
    Med Phys; 2005 Jun; 32(6):1660-75. PubMed ID: 16013725
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Monte Carlo and
    Lawless MJ; Dimaso L; Palmer B; Micka J; Culberson WS; DeWerd LA
    Med Phys; 2018 Dec; 45(12):5564-5576. PubMed ID: 30273996
    [TBL] [Abstract][Full Text] [Related]  

  • 24. [Radiation exposure of children in pediatric radiology--part 2: the PAEDOS algorithm for computer-assisted dose reconstruction in pediatric radiology and results for X-ray examinations of the skull].
    Seidenbusch MC; Regulla D; Schneider K
    Rofo; 2008 Jun; 180(6):522-39. PubMed ID: 18484514
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Establishment of a local diagnostic reference level for dental intraoral bitewing X-rays.
    Storm C; Nezich R
    Phys Eng Sci Med; 2023 Jun; 46(2):747-751. PubMed ID: 37016185
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Portable TL dosemeter--ESD phantom combination for chest and lumbar spine radiography.
    Niittymäki H; Hakanen A; Rautio S; Järvinen H
    Radiat Prot Dosimetry; 2008; 130(2):224-7. PubMed ID: 18204082
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Measurement of backscattered x-ray spectra at the water surface in the energy range 60 kV to 120 kV.
    Aoki K; Koyama M
    Phys Med Biol; 2002 Apr; 47(7):1205-17. PubMed ID: 11996064
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Dosimetry of pediatric chest X-Ray examinations in Togo.
    Adambounou K; Sedo K; Yao Adigo AM; Sonhaye L; Sodogas F; Adjenou V
    J Med Imaging Radiat Sci; 2021 Jun; 52(2):265-271. PubMed ID: 33632622
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Monte Carlo determination of a nanoDot OSLD response using quality index for diagnostic kilovoltage X-ray beams.
    Araki F
    Phys Med; 2021 Apr; 84():101-108. PubMed ID: 33887616
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Measurement of radiation dose in dental radiology.
    Helmrot E; Alm Carlsson G
    Radiat Prot Dosimetry; 2005; 114(1-3):168-71. PubMed ID: 15933101
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Evaluation of stray radiation to the operator for five hand-held dental X-ray devices.
    Smith R; Tremblay R; Wardlaw GM
    Dentomaxillofac Radiol; 2019 Jul; 48(5):20180301. PubMed ID: 30694078
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Monte carlo simulation of x-ray spectra in diagnostic radiology and mammography using MCNP4C.
    Ay MR; Shahriari M; Sarkar S; Adib M; Zaidi H
    Phys Med Biol; 2004 Nov; 49(21):4897-917. PubMed ID: 15584526
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Energy imparted to the patient in diagnostic radiology: calculation of conversion factors for determining the energy imparted from measurements of the air collision kerma integrated over beam area.
    Alm Carlsson G; Carlsson CA; Persliden J
    Phys Med Biol; 1984 Nov; 29(11):1329-41. PubMed ID: 6505015
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Evaluating TOPAS for the calculation of backscatter factors for low energy x-ray beams.
    Hewson EA; Butson MJ; Hill R
    Phys Med Biol; 2018 Oct; 63(19):195014. PubMed ID: 30183688
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Radiation exposure and dose evaluation in intraoral dental radiology.
    Poppe B; Looe HK; Pfaffenberger A; Eenboom F; Chofor N; Sering M; Rühmann A; Poplawski A; Willborn K
    Radiat Prot Dosimetry; 2007; 123(2):262-7. PubMed ID: 16971397
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Local diagnostic reference levels for intraoral dental radiography in the public hospitals of Cyprus.
    Christofides S; Pitri E; Lampaskis M; Papaefstathiou C
    Phys Med; 2016 Nov; 32(11):1437-1443. PubMed ID: 28327296
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Suggested diagnostic reference levels for paediatric X-ray examinations in India.
    Sonawane AU; Sunil Kumar JV; Singh M; Pradhan AS
    Radiat Prot Dosimetry; 2011 Nov; 147(3):423-8. PubMed ID: 21147790
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Calculation of backscatter factors for diagnostic radiology using Monte Carlo methods.
    Petoussi-Henss N; Zankl M; Drexler G; Panzer W; Regulla D
    Phys Med Biol; 1998 Aug; 43(8):2237-50. PubMed ID: 9725601
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Correction factors for the NMi free-air ionization chamber for medium-energy x-rays calculated with the Monte Carlo method.
    Grimbergen TW; van Dijk E; de Vries W
    Phys Med Biol; 1998 Nov; 43(11):3207-24. PubMed ID: 9832012
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Dosimetric characterization and organ dose assessment in digital breast tomosynthesis: Measurements and Monte Carlo simulations using voxel phantoms.
    Baptista M; Di Maria S; Barros S; Figueira C; Sarmento M; Orvalho L; Vaz P
    Med Phys; 2015 Jul; 42(7):3788-800. PubMed ID: 26133581
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.