BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

146 related articles for article (PubMed ID: 34040290)

  • 1. Optimization of Ordered Subset Expectation Maximization Parameters for Image Reconstruction in Tc-99m Methoxyisobutylisonitrile Myocardial Perfusion SPECT and Comparison with Corresponding Filtered Back Projection-Reconstructed Images.
    Dheer P; Gupta P; Taywade SK; Passah A; Pandey AK; Patel C
    Indian J Nucl Med; 2021; 36(1):14-20. PubMed ID: 34040290
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Optimization of the filter parameters in (99m)Tc myocardial perfusion SPECT studies: the formulation of flowchart.
    Shibutani T; Onoguchi M; Yamada T; Kamida H; Kunishita K; Hayashi Y; Nakajima T; Kinuya S
    Australas Phys Eng Sci Med; 2016 Jun; 39(2):571-81. PubMed ID: 27052439
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Impacts of different reconstruction methods on the image quality of cadmium-zinc-telluride-based single photon emission computed tomography/computed tomography pulmonary perfusion imaging.
    Wu W; Zhang R; Zhou Y; Wang S; Shen Y; Li N; Tan J; Zheng W; Jia Q; Meng Z
    Nucl Med Commun; 2023 Aug; 44(8):673-681. PubMed ID: 37233601
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Impact of reconstruction parameters on spatial resolution and its comparison between cadmium-zinc-telluride SPECT/CT and conventional SPECT/CT.
    Wang M; Dong S; Zhang R; Sun D; Wang S; Shen Y; Li N; Wang P; Tan J; Meng Z; Jia Q
    Nucl Med Commun; 2022 Jan; 43(1):8-16. PubMed ID: 34559760
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Optimization of Ordered Subset Expectation Maximization Reconstruction for Reducing Urinary Bladder Artifacts in Single-photon Emission Computed Tomography Imaging.
    Katua AM; Ankrah AO; Vorster M; van Gelder A; Sathekge MM
    World J Nucl Med; 2011 Jan; 10(1):3-8. PubMed ID: 22034576
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The influence of resolution recovery by using collimator detector response during 3D OSEM image reconstruction on (99m)Tc-ECD brain SPET images.
    Kalantari F; Rajabi H; Ay MR; Razavi-Ratki SK; Fard-Esfahani A; Beiki D; Eftekhari M; Fallahi B; Sadeghian L; Emami-Ardekani A
    Hell J Nucl Med; 2012; 15(2):92-7. PubMed ID: 22741145
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Influence of reconstruction parameters during filtered backprojection and ordered-subset expectation maximization in the measurement of the left-ventricular volumes and function during gated SPECT.
    Duarte DD; Monteiro MS; El Hakmaoui F; Prior JO; Vieira L; Pires-Jorge JA
    J Nucl Med Technol; 2012 Mar; 40(1):29-36. PubMed ID: 22323735
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Image quality and data quantification in dopamine transporter SPECT: advantage of 3-dimensional OSEM reconstruction?
    Winz OH; Hellwig S; Mix M; Weber WA; Mottaghy FM; Schäfer WM; Meyer PT
    Clin Nucl Med; 2012 Sep; 37(9):866-71. PubMed ID: 22889776
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Image reconstruction using filtered backprojection and iterative method: effect on motion artifacts in myocardial perfusion SPECT.
    Zakavi SR; Zonoozi A; Kakhki VD; Hajizadeh M; Momennezhad M; Ariana K
    J Nucl Med Technol; 2006 Dec; 34(4):220-3. PubMed ID: 17146110
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Preliminary evaluation of image reconstruction by ordered-subset expectation maximization in thallium-201 lung scintigraphy.
    Bai J; Yokoyama K; Kinuya S; Nakajima K; Yamada M; Ichiyanagi K; Michigishi T; Tonami N
    Ann Nucl Med; 2003 Oct; 17(7):619-24. PubMed ID: 14651366
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Human-observer receiver-operating-characteristic evaluation of attenuation, scatter, and resolution compensation strategies for (99m)Tc myocardial perfusion imaging.
    Narayanan MV; King MA; Pretorius PH; Dahlberg ST; Spencer F; Simon E; Ewald E; Healy E; MacNaught K; Leppo JA
    J Nucl Med; 2003 Nov; 44(11):1725-34. PubMed ID: 14602852
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Characterization of ordered-subsets expectation maximization with 3D post-reconstruction Gauss filtering and comparison with filtered backprojection in 99mTc SPECT.
    Brambilla M; Cannillo B; Dominietto M; Leva L; Secco C; Inglese E
    Ann Nucl Med; 2005 Apr; 19(2):75-82. PubMed ID: 15909485
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Ordered subset expectation maximization and wide beam reconstruction "half-time" gated myocardial perfusion SPECT functional imaging: a comparison to "full-time" filtered backprojection.
    DePuey EG; Gadiraju R; Clark J; Thompson L; Anstett F; Shwartz SC
    J Nucl Cardiol; 2008; 15(4):547-63. PubMed ID: 18674723
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of iterative reconstruction (OSEM) versus filtered back-projection for the assessment of myocardial glucose uptake and myocardial perfusion using dynamic PET.
    Søndergaard HM; Madsen MM; Boisen K; Bøttcher M; Schmitz O; Nielsen TT; Bøtker HE; Hansen SB
    Eur J Nucl Med Mol Imaging; 2007 Mar; 34(3):320-9. PubMed ID: 17033850
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of image reconstruction algorithms in myocardial perfusion scintigraphy.
    Bai J; Hashimoto J; Suzuki T; Nakahara T; Kubo A; Iwanaga S; Mitamura H; Ogawa S
    Ann Nucl Med; 2001 Feb; 15(1):79-83. PubMed ID: 11355789
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of different types of commercial filtered backprojection and ordered-subset expectation maximization SPECT reconstruction software.
    Seret A; Forthomme J
    J Nucl Med Technol; 2009 Sep; 37(3):179-87. PubMed ID: 19726808
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Optimization of image reconstruction method of cerebral blood flow perfusion imaging with digital CZT SPECT.
    Zhou Y; Wang S; Wang P; Li N; Wang X; Zheng W
    Nucl Med Commun; 2022 Apr; 43(4):398-409. PubMed ID: 35102075
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Pediatric 99mTc-DMSA SPECT performed by using iterative reconstruction with isotropic resolution recovery: improved image quality and reduced radiopharmaceutical activity.
    Sheehy N; Tetrault TA; Zurakowski D; Vija AH; Fahey FH; Treves ST
    Radiology; 2009 May; 251(2):511-6. PubMed ID: 19304919
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Pediatric 99mTc-MDP bone SPECT with ordered subset expectation maximization iterative reconstruction with isotropic 3D resolution recovery.
    Stansfield EC; Sheehy N; Zurakowski D; Vija AH; Fahey FH; Treves ST
    Radiology; 2010 Dec; 257(3):793-801. PubMed ID: 20858847
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effect of reconstruction algorithms on myocardial blood flow measurement with 13N-ammonia PET.
    Chen GP; Branch KR; Alessio AM; Pham P; Tabibiazar R; Kinahan P; Caldwell JH
    J Nucl Med; 2007 Aug; 48(8):1259-65. PubMed ID: 17631543
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.