These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
157 related articles for article (PubMed ID: 34041513)
1. A real-time LAMP-based dual-sample microfluidic chip for rapid and simultaneous detection of multiple waterborne pathogenic bacteria from coastal waters. Jin J; Duan L; Fu J; Chai F; Zhou Q; Wang Y; Shao X; Wang L; Yan M; Su X; Zhang Y; Pan J; Chen J Anal Methods; 2021 Jun; 13(24):2710-2721. PubMed ID: 34041513 [TBL] [Abstract][Full Text] [Related]
2. Simultaneous detection of multiple bacterial and viral aquatic pathogens using a fluorogenic loop-mediated isothermal amplification-based dual-sample microfluidic chip. Zhou QJ; Lu JF; Su XR; Jin JL; Li SY; Zhou Y; Wang L; Shao XB; Wang YH; Yan MC; Li MY; Chen J J Fish Dis; 2021 Apr; 44(4):401-413. PubMed ID: 33340375 [TBL] [Abstract][Full Text] [Related]
3. Development and evaluation of a real-time fluorogenic loop-mediated isothermal amplification assay integrated on a microfluidic disc chip (on-chip LAMP) for rapid and simultaneous detection of ten pathogenic bacteria in aquatic animals. Zhou QJ; Wang L; Chen J; Wang RN; Shi YH; Li CH; Zhang DM; Yan XJ; Zhang YJ J Microbiol Methods; 2014 Sep; 104():26-35. PubMed ID: 24954661 [TBL] [Abstract][Full Text] [Related]
4. A real-time isothermal amplification based portable microfluidic system for simple and reliable detection of Zhong R; Liu S; Wang X; Zhang G; Gong N; Wang M; Sun Y Anal Methods; 2020 Jun; 12(23):2985-2994. PubMed ID: 32930158 [TBL] [Abstract][Full Text] [Related]
5. Rapid detection of multiple pathogens by the combined loop-mediated isothermal amplification technology and microfluidic chip technology. Ou H; Wang Y; Wang Q; Ma Y; Liu C; Jia L; Zhang Q; Li M; Feng X; Li M; Wang X; Wang C Ann Palliat Med; 2021 Oct; 10(10):11053-11066. PubMed ID: 34763467 [TBL] [Abstract][Full Text] [Related]
6. Rapid and simultaneous detection of multiple pathogens in the lower reproductive tract during pregnancy based on loop-mediated isothermal amplification-microfluidic chip. Xu X; Jia Y; Li R; Wen Y; Liang Y; Lao G; Liu X; Zhou W; Liu H; Xie J; Wang X; Xu W; Sun Q BMC Microbiol; 2022 Oct; 22(1):260. PubMed ID: 36309654 [TBL] [Abstract][Full Text] [Related]
7. Comparative analysis of loop-mediated isothermal amplification combined with microfluidic chip technology and q-PCR in the detection of clinical infectious pathogens. Zhang E; Ou H; Jia L; Zhang W; Wang Y; Wang X J Clin Lab Anal; 2022 Aug; 36(8):e24565. PubMed ID: 35754145 [TBL] [Abstract][Full Text] [Related]
8. Rapid and Quantitative Detection of Vibrio parahemolyticus by the Mixed-Dye-Based Loop-Mediated Isothermal Amplification Assay on a Self-Priming Compartmentalization Microfluidic Chip. Pang B; Ding X; Wang G; Zhao C; Xu Y; Fu K; Sun J; Song X; Wu W; Liu Y; Song Q; Hu J; Li J; Mu Y J Agric Food Chem; 2017 Dec; 65(51):11312-11319. PubMed ID: 29198118 [TBL] [Abstract][Full Text] [Related]
9. Development of a duplex lateral flow dipstick test for the detection and differentiation of Listeria spp. and Listeria monocytogenes in meat products based on loop-mediated isothermal amplification. Ledlod S; Bunroddith K; Areekit S; Santiwatanakul S; Chansiri K J Chromatogr B Analyt Technol Biomed Life Sci; 2020 Feb; 1139():121834. PubMed ID: 31812649 [TBL] [Abstract][Full Text] [Related]
10. Parallel detection of multiple zoonotic parasites using a real-time fluorogenic loop-mediated isothermal amplification-based quadruple-sample microfluidic chip. Chen YX; Lou YR; Duan LJ; Zhou QJ; Xu ZJ; Chen FJ; Chen HX; Xu GZ; Du AF; Chen J Front Microbiol; 2023; 14():1238376. PubMed ID: 37822745 [TBL] [Abstract][Full Text] [Related]
11. Rapid and Sensitive Detection of Vibrio parahaemolyticus and Vibrio vulnificus by Multiple Endonuclease Restriction Real-Time Loop-Mediated Isothermal Amplification Technique. Wang Y; Li D; Wang Y; Li K; Ye C Molecules; 2016 Jan; 21(1):E111. PubMed ID: 26797596 [TBL] [Abstract][Full Text] [Related]
12. Pathogenic Bacteria Detection Using RNA-Based Loop-Mediated Isothermal-Amplification-Assisted Nucleic Acid Amplification via Droplet Microfluidics. Azizi M; Zaferani M; Cheong SH; Abbaspourrad A ACS Sens; 2019 Apr; 4(4):841-848. PubMed ID: 30908029 [TBL] [Abstract][Full Text] [Related]
13. A polymer microfluidic chip for quantitative detection of multiple water- and foodborne pathogens using real-time fluorogenic loop-mediated isothermal amplification. Tourlousse DM; Ahmad F; Stedtfeld RD; Seyrig G; Tiedje JM; Hashsham SA Biomed Microdevices; 2012 Aug; 14(4):769-78. PubMed ID: 22566273 [TBL] [Abstract][Full Text] [Related]
14. Detection of Salmonella spp. by a loop-mediated isothermal amplification (LAMP) method targeting bcfD gene. Zhuang L; Gong J; Li Q; Zhu C; Yu Y; Dou X; Liu X; Xu B; Wang C Lett Appl Microbiol; 2014 Dec; 59(6):658-64. PubMed ID: 25199410 [TBL] [Abstract][Full Text] [Related]
15. Evaluation of a novel lysis-based sample processing method to optimize Vibrio vulnificus detecting by loop-mediated isothermal amplification assay. Zhang L; Liu J; Qin K; Wu C; Ma H; Zhou L BMC Microbiol; 2024 Jan; 24(1):37. PubMed ID: 38279108 [TBL] [Abstract][Full Text] [Related]
16. A Comparison of In-House Real-Time LAMP Assays with a Commercial Assay for the Detection of Pathogenic Bacteria. Wang D; Wang Y; Xiao F; Guo W; Zhang Y; Wang A; Liu Y Molecules; 2015 May; 20(6):9487-95. PubMed ID: 26020698 [TBL] [Abstract][Full Text] [Related]
17. A loop-mediated isothermal amplification-based microfluidic chip for triplex detection of shrimp pathogens. Hu K; Li Y; Wang F; Liu J; Li Y; Zhao Q; Zheng X; Zhu N; Yu X; Fang S; Huang J J Fish Dis; 2023 Feb; 46(2):137-146. PubMed ID: 36336976 [TBL] [Abstract][Full Text] [Related]
18. Loop-mediated isothermal amplification-based microfluidic chip for pathogen detection. Shang Y; Sun J; Ye Y; Zhang J; Zhang Y; Sun X Crit Rev Food Sci Nutr; 2020; 60(2):201-224. PubMed ID: 30569743 [TBL] [Abstract][Full Text] [Related]
19. A microdevice for rapid, monoplex and colorimetric detection of foodborne pathogens using a centrifugal microfluidic platform. Sayad A; Ibrahim F; Mukim Uddin S; Cho J; Madou M; Thong KL Biosens Bioelectron; 2018 Feb; 100():96-104. PubMed ID: 28869845 [TBL] [Abstract][Full Text] [Related]
20. Detection of 12 Common Food-Borne Bacterial Pathogens by TaqMan Real-Time PCR Using a Single Set of Reaction Conditions. Liu Y; Cao Y; Wang T; Dong Q; Li J; Niu C Front Microbiol; 2019; 10():222. PubMed ID: 30814987 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]