These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
172 related articles for article (PubMed ID: 34058675)
1. Amperometric determination of ecotoxic N-methyl-p-aminophenol sulfate in photographic solution and river water samples based on graphene oxide/CeNbO Mutharani B; Gopi PK; Chen SM; Tsai HC; Ahmed F; Haidyrah AS; Ranganathan P Ecotoxicol Environ Saf; 2021 Sep; 220():112373. PubMed ID: 34058675 [TBL] [Abstract][Full Text] [Related]
2. Electrochemical sensing base for hazardous herbicide aclonifen using gadolinium niobate (GdNbO Gopi PK; Mutharani B; Chen SM; Chen TW; Eldesoky GE; Ali MA; Wabaidur SM; Shaik F; Tzu CY Ecotoxicol Environ Saf; 2021 Jan; 207():111285. PubMed ID: 32931964 [TBL] [Abstract][Full Text] [Related]
3. Graphene oxide@Ce-doped TiO Nehru R; Hsu YF; Wang SF; Dong CD; Govindasamy M; Habila MA; AlMasoud N Mikrochim Acta; 2021 May; 188(6):216. PubMed ID: 34052922 [TBL] [Abstract][Full Text] [Related]
4. Novel Electrochemical Sensors Based on Cuprous Oxide-Electrochemically Reduced Graphene Oxide Nanocomposites Modified Electrode toward Sensitive Detection of Sunset Yellow. He Q; Liu J; Liu X; Xia Y; Li G; Deng P; Chen D Molecules; 2018 Aug; 23(9):. PubMed ID: 30149513 [TBL] [Abstract][Full Text] [Related]
5. Tailoring of bismuth vanadate impregnated on molybdenum/graphene oxide sheets for sensitive detection of environmental pollutants 2, 4, 6 trichlorophenol. Gopi PK; Ravikumar CH; Chen SM; Chen TW; Ali MA; Al-Hemaid FMA; El-Shikh MS; Alnakhli AK Ecotoxicol Environ Saf; 2021 Mar; 211():111934. PubMed ID: 33472109 [TBL] [Abstract][Full Text] [Related]
6. Very sensitive electrochemical determination of diuron on glassy carbon electrode modified with reduced graphene oxide-gold nanoparticle-Nafion composite film. Zarei K; Khodadadi A Ecotoxicol Environ Saf; 2017 Oct; 144():171-177. PubMed ID: 28622555 [TBL] [Abstract][Full Text] [Related]
7. In situ electrochemical synthesis of highly loaded zirconium nanoparticles decorated reduced graphene oxide for the selective determination of dopamine and paracetamol in presence of ascorbic acid. Ezhil Vilian AT; Rajkumar M; Chen SM Colloids Surf B Biointerfaces; 2014 Mar; 115():295-301. PubMed ID: 24384145 [TBL] [Abstract][Full Text] [Related]
8. A cobalt oxide nanocubes interleaved reduced graphene oxide nanocomposite modified glassy carbon electrode for amperometric detection of serotonin. Shahid MM; Rameshkumar P; Numan A; Shahabuddin S; Alizadeh M; Khiew PS; Chiu WS Mater Sci Eng C Mater Biol Appl; 2019 Jul; 100():388-395. PubMed ID: 30948075 [TBL] [Abstract][Full Text] [Related]
9. Amperometric sensor based on tricobalt tetroxide nanoparticles-graphene nanocomposite film modified glassy carbon electrode for determination of tyrosine. Jiang L; Gu S; Ding Y; Ye D; Zhang Z; Zhang F Colloids Surf B Biointerfaces; 2013 Jul; 107():146-51. PubMed ID: 23475062 [TBL] [Abstract][Full Text] [Related]
11. Fe3O4 magnetic nanoparticles/reduced graphene oxide nanosheets as a novel electrochemical and bioeletrochemical sensing platform. Teymourian H; Salimi A; Khezrian S Biosens Bioelectron; 2013 Nov; 49():1-8. PubMed ID: 23708810 [TBL] [Abstract][Full Text] [Related]
12. Glassy carbon electrode modified with 7,7,8,8-tetracyanoquinodimethane and graphene oxide triggered a synergistic effect: Low-potential amperometric detection of reduced glutathione. Yuan B; Xu C; Zhang R; Lv D; Li S; Zhang D; Liu L; Fernandez C Biosens Bioelectron; 2017 Oct; 96():1-7. PubMed ID: 28448855 [TBL] [Abstract][Full Text] [Related]
13. A sensitive non-enzymatic electrochemical sensor based on acicular manganese dioxide modified graphene nanosheets composite for hydrogen peroxide detection. Guan JF; Huang ZN; Zou J; Jiang XY; Peng DM; Yu JG Ecotoxicol Environ Saf; 2020 Mar; 190():110123. PubMed ID: 31891837 [TBL] [Abstract][Full Text] [Related]
14. Ultrasensitive detection of food colorant sunset yellow using nickel nanoparticles promoted lettuce-like spinel Co Balram D; Lian KY; Sebastian N; Al-Mubaddel FS; Noman MT Food Chem Toxicol; 2022 Jan; 159():112725. PubMed ID: 34856315 [TBL] [Abstract][Full Text] [Related]
15. A selective analysis of sulfamethoxazole - Trimethoprim in tablet formulations using graphene oxide-zinc oxide quantum dots based nanocomposite modified glassy carbon electrode. Senthil Kumar P; G P; Elavarasan N; Sreeja BS Chemosphere; 2023 Aug; 332():138814. PubMed ID: 37149102 [TBL] [Abstract][Full Text] [Related]
16. Phytic acid/graphene oxide nanocomposites modified electrode for electrochemical sensing of dopamine. Wang D; Xu F; Hu J; Lin M Mater Sci Eng C Mater Biol Appl; 2017 Feb; 71():1086-1089. PubMed ID: 27987663 [TBL] [Abstract][Full Text] [Related]
17. Manganese dioxide Nanorods/electrochemically reduced graphene oxide nanocomposites modified electrodes for cost-effective and ultrasensitive detection of Amaranth. He Q; Liu J; Liu X; Li G; Deng P; Liang J Colloids Surf B Biointerfaces; 2018 Dec; 172():565-572. PubMed ID: 30218982 [TBL] [Abstract][Full Text] [Related]
18. Lead sensors development and antimicrobial activities based on graphene oxide/carbon nanotube/poly(O-toluidine) nanocomposite. Khan AA; Khan A; Rahman MM; Asiri AM; Oves M Int J Biol Macromol; 2016 Aug; 89():198-205. PubMed ID: 27112981 [TBL] [Abstract][Full Text] [Related]
19. Sonochemical and sustainable synthesis of graphene-gold (G-Au) nanocomposites for enzymeless and selective electrochemical detection of nitric oxide. Geetha Bai R; Muthoosamy K; Zhou M; Ashokkumar M; Huang NM; Manickam S Biosens Bioelectron; 2017 Jan; 87():622-629. PubMed ID: 27616288 [TBL] [Abstract][Full Text] [Related]
20. Amperometric sensing of hydrazine in environmental and biological samples by using CeO Huang H; Li T; Sun Y; Yu L; Wang C; Shen R; Ye W; Wang D; Li Y Mikrochim Acta; 2019 Jan; 186(1):46. PubMed ID: 30610467 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]