These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

105 related articles for article (PubMed ID: 34058947)

  • 1. Water-cooled microwave ablation array for bloodless rapid transection of the liver.
    Yang Q; Li W; Chen Z; Chen D; Du Y; Lang L; Ye Z; Shen S; Lei Z; Zhang S
    Int J Hyperthermia; 2021; 38(1):823-829. PubMed ID: 34058947
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Computer modeling and
    Chen DD; Du YX; Chen ZB; Lang L; Ye Z; Yang Q; Shen SQ; Lei ZY; Zhang SQ
    Minim Invasive Ther Allied Technol; 2021 Feb; 30(1):12-20. PubMed ID: 31597487
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Internally gas-cooled radiofrequency applicators as an alternative to conventional radiofrequency and microwave ablation devices: an in vivo comparison.
    Rempp H; Voigtländer M; Schenk M; Enderle MD; Scharpf M; Greiner TO; Neugebauer A; Hoffmann R; Claussen CD; Clasen S
    Eur J Radiol; 2013 Aug; 82(8):e350-5. PubMed ID: 23522746
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A comparison of microwave ablation and bipolar radiofrequency ablation both with an internally cooled probe: results in ex vivo and in vivo porcine livers.
    Yu J; Liang P; Yu X; Liu F; Chen L; Wang Y
    Eur J Radiol; 2011 Jul; 79(1):124-30. PubMed ID: 20047812
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Research and development of a new RF-assisted device for bloodless rapid transection of the liver: computational modeling and in vivo experiments.
    Burdío F; Berjano EJ; Navarro A; Burdío JM; Grande L; Gonzalez A; Cruz I; Güemes A; Sousa R; Subirá J; Castiella T; Poves I; Lequerica JL
    Biomed Eng Online; 2009 Mar; 8():6. PubMed ID: 19296852
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Liver cancer: increased microwave delivery to ablation zone with cooled-shaft antenna--experimental and clinical studies.
    Kuang M; Lu MD; Xie XY; Xu HX; Mo LQ; Liu GJ; Xu ZF; Zheng YL; Liang JY
    Radiology; 2007 Mar; 242(3):914-24. PubMed ID: 17229876
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A radiofrequency-assisted device for bloodless rapid transection of the liver: a comparative study in a pig liver model.
    Burdío F; Navarro A; Berjano E; Sousa R; Burdío JM; Güemes A; Subiró J; Gonzalez A; Cruz I; Castiella T; Tejero E; Lozano R; Grande L; de Gregorio MA
    Eur J Surg Oncol; 2008 May; 34(5):599-605. PubMed ID: 17614248
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Comparison between biliary cirrhosis and normal porcine liver treated with microwave ablation using a cooled-tip electrode].
    Fan WJ; Wang LG; Zheng YB; Zhang L; Tang T; Li X; Jiang H; Zhang JL
    Zhonghua Yi Xue Za Zhi; 2011 Nov; 91(41):2942-6. PubMed ID: 22333620
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Microwave ablation: An experimental comparative study on internally cooled antenna versus non-internally cooled antenna in liver models.
    He N; Wang W; Ji Z; Li C; Huang B
    Acad Radiol; 2010 Jul; 17(7):894-9. PubMed ID: 20540911
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Combination Therapies: Quantifying the Effects of Transarterial Embolization on Microwave Ablation Zones.
    Knavel EM; Green CM; Gendron-Fitzpatrick A; Brace CL; Laeseke PF
    J Vasc Interv Radiol; 2018 Jul; 29(7):1050-1056. PubMed ID: 29754849
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Laparoscopic blood-saving liver resection using a new radiofrequency-assisted device: preliminary report of an in vivo study with pig liver.
    Navarro A; Burdio F; Berjano EJ; Güemes A; Sousa R; Rufas M; Subirá J; Gonzalez A; Burdío JM; Castiella T; Tejero E; De Gregorio MA; Grande L; Lozano R
    Surg Endosc; 2008 May; 22(5):1384-91. PubMed ID: 18322742
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of temperature curve and ablation zone between 915- and 2450-MHz cooled-shaft microwave antenna: results in ex vivo porcine livers.
    Sun Y; Cheng Z; Dong L; Zhang G; Wang Y; Liang P
    Eur J Radiol; 2012 Mar; 81(3):553-7. PubMed ID: 21354733
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of microwave ablation and multipolar radiofrequency ablation in vivo using two internally cooled probes.
    Fan W; Li X; Zhang L; Jiang H; Zhang J
    AJR Am J Roentgenol; 2012 Jan; 198(1):W46-50. PubMed ID: 22194514
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Investigation of Microwave Ablation Process in Sweet Potatoes as Substitute Liver.
    Khan MS; Hawlitzki M; Taheri SM; Rose G; Schweizer B; Brensing A
    Sensors (Basel); 2021 Jun; 21(11):. PubMed ID: 34200011
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Bipolar radiofrequency ablation in ex vivo bovine liver with the open-perfused system versus the cooled-wet system.
    Lee JM; Han JK; Kim SH; Sohn KL; Choi SH; Choi BI
    Eur Radiol; 2005 Apr; 15(4):759-64. PubMed ID: 15248081
    [TBL] [Abstract][Full Text] [Related]  

  • 16. 915MHz microwave ablation with high output power in in vivo porcine spleens.
    Gao Y; Wang Y; Duan Y; Li C; Sun Y; Zhang D; Lu T; Liang P
    Eur J Radiol; 2010 Jul; 75(1):87-90. PubMed ID: 19349134
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Microwave ablation of the liver in a live porcine model: the impact of power, time and total energy on ablation zone size and shape.
    Hui TCH; Brace CL; Hinshaw JL; Quek LHH; Huang IKH; Kwan J; Lim GHT; Lee FT; Pua U
    Int J Hyperthermia; 2020; 37(1):668-676. PubMed ID: 32552123
    [No Abstract]   [Full Text] [Related]  

  • 18. Linear radiofrequency ablation using dual switching-control mode achieves rapid and bloodless liver resection, an experimental research.
    Hsiao CY; Yang PC; Huang KW
    Int J Hyperthermia; 2021; 38(1):357-362. PubMed ID: 33641575
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Microwave ablation: results in ex vivo and in vivo porcine livers with 2450-MHz cooled-shaft antenna.
    Zhou Q; Jin X; Jiao DC; Zhang FJ; Zhang L; Han XW; Duan GF; Han JJ; Li CX
    Chin Med J (Engl); 2011 Oct; 124(20):3386-93. PubMed ID: 22088540
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Microwave-assisted liver resection vs. clamp crushing liver resection in cirrhosis patients with hepatocellular carcinoma.
    Chen ZB; Qin F; Ye Z; Shen SQ; Li W; Ding YM; Hu QY; Ma Y
    Int J Hyperthermia; 2018 Dec; 34(8):1359-1366. PubMed ID: 29353503
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.