BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

156 related articles for article (PubMed ID: 34077554)

  • 1. Range probing as a quality control tool for CBCT-based synthetic CTs: In vivo application for head and neck cancer patients.
    Seller Oria C; Thummerer A; Free J; Langendijk JA; Both S; Knopf AC; Meijers A
    Med Phys; 2021 Aug; 48(8):4498-4505. PubMed ID: 34077554
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of CBCT based synthetic CT methods suitable for proton dose calculations in adaptive proton therapy.
    Thummerer A; Zaffino P; Meijers A; Marmitt GG; Seco J; Steenbakkers RJHM; Langendijk JA; Both S; Spadea MF; Knopf AC
    Phys Med Biol; 2020 Apr; 65(9):095002. PubMed ID: 32143207
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Clinical suitability of deep learning based synthetic CTs for adaptive proton therapy of lung cancer.
    Thummerer A; Seller Oria C; Zaffino P; Meijers A; Guterres Marmitt G; Wijsman R; Seco J; Langendijk JA; Knopf AC; Spadea MF; Both S
    Med Phys; 2021 Dec; 48(12):7673-7684. PubMed ID: 34725829
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Deep learning-based 4D-synthetic CTs from sparse-view CBCTs for dose calculations in adaptive proton therapy.
    Thummerer A; Seller Oria C; Zaffino P; Visser S; Meijers A; Guterres Marmitt G; Wijsman R; Seco J; Langendijk JA; Knopf AC; Spadea MF; Both S
    Med Phys; 2022 Nov; 49(11):6824-6839. PubMed ID: 35982630
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of the suitability of CBCT- and MR-based synthetic CTs for daily adaptive proton therapy in head and neck patients.
    Thummerer A; de Jong BA; Zaffino P; Meijers A; Marmitt GG; Seco J; Steenbakkers RJHM; Langendijk JA; Both S; Spadea MF; Knopf AC
    Phys Med Biol; 2020 Dec; 65(23):235036. PubMed ID: 33179874
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Technical note: Evaluation of deep learning based synthetic CTs clinical readiness for dose and NTCP driven head and neck adaptive proton therapy.
    de Koster RJC; Thummerer A; Scandurra D; Langendijk JA; Both S
    Med Phys; 2023 Dec; 50(12):8023-8033. PubMed ID: 37831597
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Cone beam CT based validation of neural network generated synthetic CTs for radiotherapy in the head region.
    Irmak S; Zimmermann L; Georg D; Kuess P; Lechner W
    Med Phys; 2021 Aug; 48(8):4560-4571. PubMed ID: 34028053
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Feasibility of Monte Carlo dropout-based uncertainty maps to evaluate deep learning-based synthetic CTs for adaptive proton therapy.
    Galapon AV; Thummerer A; Langendijk JA; Wagenaar D; Both S
    Med Phys; 2024 Apr; 51(4):2499-2509. PubMed ID: 37956266
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Dosimetric evaluation of synthetic CT for head and neck radiotherapy generated by a patch-based three-dimensional convolutional neural network.
    Dinkla AM; Florkow MC; Maspero M; Savenije MHF; Zijlstra F; Doornaert PAH; van Stralen M; Philippens MEP; van den Berg CAT; Seevinck PR
    Med Phys; 2019 Sep; 46(9):4095-4104. PubMed ID: 31206701
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Improving CBCT quality to CT level using deep learning with generative adversarial network.
    Zhang Y; Yue N; Su MY; Liu B; Ding Y; Zhou Y; Wang H; Kuang Y; Nie K
    Med Phys; 2021 Jun; 48(6):2816-2826. PubMed ID: 33259647
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Dosimetric evaluation of cone-beam CT-based synthetic CTs in pediatric patients undergoing intensity-modulated proton therapy.
    Sheikh K; Liu D; Li H; Acharya S; Ladra MM; Hrinivich WT
    J Appl Clin Med Phys; 2022 Jun; 23(6):e13604. PubMed ID: 35413144
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Head and neck synthetic CT generated from ultra-low-dose cone-beam CT following Image Gently Protocol using deep neural network.
    Yuan N; Rao S; Chen Q; Sensoy L; Qi J; Rong Y
    Med Phys; 2022 May; 49(5):3263-3277. PubMed ID: 35229904
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Technical Note: First report on an in vivo range probing quality control procedure for scanned proton beam therapy in head and neck cancer patients.
    Meijers A; Seller Oria C; Free J; Langendijk JA; Knopf AC; Both S
    Med Phys; 2021 Mar; 48(3):1372-1380. PubMed ID: 33428795
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Measurement-based range evaluation for quality assurance of CBCT-based dose calculations in adaptive proton therapy.
    Neppl S; Kurz C; Köpl D; Yohannes I; Schneider M; Bondesson D; Rabe M; Belka C; Dietrich O; Landry G; Parodi K; Kamp F
    Med Phys; 2021 Aug; 48(8):4148-4159. PubMed ID: 34032301
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Investigating CT to CBCT image registration for head and neck proton therapy as a tool for daily dose recalculation.
    Landry G; Nijhuis R; Dedes G; Handrack J; Thieke C; Janssens G; Orban de Xivry J; Reiner M; Kamp F; Wilkens JJ; Paganelli C; Riboldi M; Baroni G; Ganswindt U; Belka C; Parodi K
    Med Phys; 2015 Mar; 42(3):1354-66. PubMed ID: 25735290
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Deep learning approaches using 2D and 3D convolutional neural networks for generating male pelvic synthetic computed tomography from magnetic resonance imaging.
    Fu J; Yang Y; Singhrao K; Ruan D; Chu FI; Low DA; Lewis JH
    Med Phys; 2019 Sep; 46(9):3788-3798. PubMed ID: 31220353
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluating AI-generated CBCT-based synthetic CT images for target delineation in palliative treatments of pelvic bone metastasis at conventional C-arm linacs.
    Hoffmans-Holtzer N; Magallon-Baro A; de Pree I; Slagter C; Xu J; Thill D; Olofsen-van Acht M; Hoogeman M; Petit S
    Radiother Oncol; 2024 Mar; 192():110110. PubMed ID: 38272314
    [TBL] [Abstract][Full Text] [Related]  

  • 18. CBCT-based synthetic CT generation using deep-attention cycleGAN for pancreatic adaptive radiotherapy.
    Liu Y; Lei Y; Wang T; Fu Y; Tang X; Curran WJ; Liu T; Patel P; Yang X
    Med Phys; 2020 Jun; 47(6):2472-2483. PubMed ID: 32141618
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A single neural network for cone-beam computed tomography-based radiotherapy of head-and-neck, lung and breast cancer.
    Maspero M; Houweling AC; Savenije MHF; van Heijst TCF; Verhoeff JJC; Kotte ANTJ; van den Berg CAT
    Phys Imaging Radiat Oncol; 2020 Apr; 14():24-31. PubMed ID: 33458310
    [No Abstract]   [Full Text] [Related]  

  • 20. Deep learning-based thoracic CBCT correction with histogram matching.
    Qiu RLJ; Lei Y; Shelton J; Higgins K; Bradley JD; Curran WJ; Liu T; Kesarwala AH; Yang X
    Biomed Phys Eng Express; 2021 Oct; 7(6):. PubMed ID: 34654011
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.