These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
124 related articles for article (PubMed ID: 34077758)
21. Hemolysis Interference: Are Laboratories Getting the Information They Need? Farrell CJ; Carter AC Clin Chem; 2016 Sep; 62(9):1274-6. PubMed ID: 27413077 [No Abstract] [Full Text] [Related]
22. Interference in clinical chemistry assays by the hemoglobin-based oxygen carrier, Hemospan. Cameron SJ; Gerhardt G; Engelstad M; Young MA; Norris EJ; Sokoll LJ Clin Biochem; 2009 Feb; 42(3):221-4. PubMed ID: 19028481 [TBL] [Abstract][Full Text] [Related]
23. Interference by haemolysis, icterus and lipaemia in assays on the Beckman Synchron CX5 and methods for correction. Randall AG; Garcia-Webb P; Beilby JP Ann Clin Biochem; 1990 Jul; 27 ( Pt 4)():345-52. PubMed ID: 2403233 [TBL] [Abstract][Full Text] [Related]
26. Falsely Increased Plasma Lactate Dehydrogenase without Hemolysis Following Transport through Pneumatic Tube System. Herman DS; Toro E; Baraban EG; Bagg A; Wang P J Appl Lab Med; 2019 Nov; 4(3):433-438. PubMed ID: 31659082 [TBL] [Abstract][Full Text] [Related]
27. A method for determining the concentration of haptoglobin in cattle blood following haemolysis caused at collection. Slocombe LL; Colditz IG Res Vet Sci; 2012 Aug; 93(1):190-4. PubMed ID: 21663927 [TBL] [Abstract][Full Text] [Related]
28. [Haemolysis and turbidity influence on three analysis methods of quantitative determination of total and conjugated bilirubin on ADVIA 1650]. Gobert De Paepe E; Munteanu G; Schischmanoff PO; Porquet D Ann Biol Clin (Paris); 2008; 66(2):175-82. PubMed ID: 18390427 [TBL] [Abstract][Full Text] [Related]
29. Minor improvement of venous blood specimen collection practices in primary health care after a large-scale educational intervention. Bölenius K; Söderberg J; Hultdin J; Lindkvist M; Brulin C; Grankvist K Clin Chem Lab Med; 2013 Feb; 51(2):303-10. PubMed ID: 23096106 [TBL] [Abstract][Full Text] [Related]
31. Effects of the hemolytic index on the test results of a dry chemistry analyzer and a verification of the hemolytic interference threshold. Yang Q; Huang S; Han R; Lin B; Liu Q; Duan X; Ma Z; Zhang H; Shou H; Zhang S Ann Palliat Med; 2022 Apr; 11(4):1381-1390. PubMed ID: 35523746 [TBL] [Abstract][Full Text] [Related]
32. Hemoglobin interference from in vivo hemolysis. Blank DW; Kroll MH; Ruddel ME; Elin RJ Clin Chem; 1985 Sep; 31(9):1566-9. PubMed ID: 4028407 [TBL] [Abstract][Full Text] [Related]
33. Verifying the nonreporting hemolysis index for potassium, phosphate, magnesium, AST, LDH, iron, CA 19-9, and vitamin D, using Beckman Coulter AU5800 and DxI800 automated analyzers. Sheerin S Lab Med; 2024 Sep; 55(5):624-626. PubMed ID: 38639324 [TBL] [Abstract][Full Text] [Related]
34. Case report of unexplained hypocalcaemia in a slightly haemolysed sample. Cornes M Biochem Med (Zagreb); 2017 Jun; 27(2):426-429. PubMed ID: 28694734 [TBL] [Abstract][Full Text] [Related]
35. Specimen rejection in laboratory medicine: Necessary for patient safety? Dikmen ZG; Pinar A; Akbiyik F Biochem Med (Zagreb); 2015; 25(3):377-85. PubMed ID: 26527231 [TBL] [Abstract][Full Text] [Related]
36. Point-of-care hemolysis detection in blood gas specimens directly at the emergency department. Duhalde H; Skogö J; Karlsson M Scand J Clin Lab Invest; 2019 Sep; 79(5):283-287. PubMed ID: 31066302 [TBL] [Abstract][Full Text] [Related]
37. Blood venous sample collection: Recommendations overview and a checklist to improve quality. Giavarina D; Lippi G Clin Biochem; 2017 Jul; 50(10-11):568-573. PubMed ID: 28242283 [TBL] [Abstract][Full Text] [Related]
38. Effect of hemolysis on insulin determination by the Beckman Coulter Unicell DXI 800 immunoassay analyzer. Cook PR; Glenn C; Armston A Clin Biochem; 2010 Apr; 43(6):621-2. PubMed ID: 20080083 [TBL] [Abstract][Full Text] [Related]
39. Determination of hemolysis index thresholds for biochemical tests on Siemens Advia 2400 chemistry analyzer. Du Z; Liu J; Zhang H; Bao B; Zhao R; Jin Y J Clin Lab Anal; 2019 May; 33(4):e22856. PubMed ID: 30779463 [TBL] [Abstract][Full Text] [Related]
40. Impact of pre-analytical variables in the determination of serum galactomannan. Monteiro AA; Rubenich DS; Zandoná MR; Pasqualotto AC Med Mycol; 2017 Aug; 55(6):635-641. PubMed ID: 27838643 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]