These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

98 related articles for article (PubMed ID: 3408036)

  • 1. [High frequency ventilation. Study of the mechanisms of action].
    Theissen JL; Lunkenheimer PP; Mersch FJ; Frieling G; Redmann K; Lawin P
    Ann Fr Anesth Reanim; 1988; 7(3):233-8. PubMed ID: 3408036
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [High-frequency ventilation. I. Distribution of alveolar pressure amplitudes during high frequency oscillation in the lung model].
    Theissen J; Lunkenheimer PP; Niederer P; Bush E; Frieling G; Lawin P
    Anaesthesist; 1987 Sep; 36(9):480-5. PubMed ID: 3120618
    [TBL] [Abstract][Full Text] [Related]  

  • 3. High-frequency oscillation in an adult porcine model.
    Lunkenheimer PP; Redmann K; Stroh N; Gleich C; Krebs S; Scheld HH; Dietl KH; Fischer S; Whimster WF
    Crit Care Med; 1994 Sep; 22(9 Suppl):S37-48. PubMed ID: 8070269
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Hemodynamic effects of different modes of mechanical ventilation in acute cardiac and pulmonary failure: an experimental study.
    Zobel G; Dacar D; Rödl S
    Crit Care Med; 1994 Oct; 22(10):1624-30. PubMed ID: 7924375
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [High-frequency pulmonary ventilation in general surgical and intrathoracic surgical interventions].
    Nefedov AV; Chernyĭ SM; Khorokhordin NE; Kovalev MG
    Anesteziol Reanimatol; 1994; (2):28-32. PubMed ID: 8059992
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Prolonged partial liquid ventilation using conventional and high-frequency ventilatory techniques: gas exchange and lung pathology in an animal model of respiratory distress syndrome.
    Smith KM; Mrozek JD; Simonton SC; Bing DR; Meyers PA; Connett JE; Mammel MC
    Crit Care Med; 1997 Nov; 25(11):1888-97. PubMed ID: 9366775
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Experiences with the use of oscillating high frequency ventilation].
    Harzendorf E; Müller E; Voigt H; Bomm M; Oddoy A; Merker G; Danzmann E
    Z Erkr Atmungsorgane; 1989; 172(3):265-71. PubMed ID: 2800610
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Specific compliance and gas exchange during high-frequency oscillatory ventilation.
    Wood B; Karna P; Adams A
    Crit Care Med; 2002 Jul; 30(7):1523-7. PubMed ID: 12130973
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Flow dynamics using high-frequency jet ventilation in a model of bronchopleural fistula.
    Wood MJ; Lin ES; Thompson JP
    Br J Anaesth; 2014 Feb; 112(2):355-66. PubMed ID: 24172056
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Soluble gas exchange in the pulmonary airways of sheep.
    Schimmel C; Bernard SL; Anderson JC; Polissar NL; Lakshminarayan S; Hlastala MP
    J Appl Physiol (1985); 2004 Nov; 97(5):1702-8. PubMed ID: 15220303
    [TBL] [Abstract][Full Text] [Related]  

  • 11. High-frequency oscillatory ventilation of the perfluorocarbon-filled lung: preliminary results in an animal model of acute lung injury.
    Doctor A; Mazzoni MC; DelBalzo U; DiCanzio J; Arnold JH
    Crit Care Med; 1999 Nov; 27(11):2500-7. PubMed ID: 10579271
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [High-frequency artificial respiration. II. Intratracheal high-frequency pressure changes with a rotation-valve catheter].
    Theissen J; Lunkenheimer PP; Frieling G; Niederer P; Stroh N; Bossler R; Mersch J; Redmann K
    Anaesthesist; 1988 Mar; 37(3):182-6. PubMed ID: 3381994
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Open-lung protective ventilation with pressure control ventilation, high-frequency oscillation, and intratracheal pulmonary ventilation results in similar gas exchange, hemodynamics, and lung mechanics.
    Sedeek KA; Takeuchi M; Suchodolski K; Vargas SO; Shimaoka M; Schnitzer JJ; Kacmarek RM
    Anesthesiology; 2003 Nov; 99(5):1102-11. PubMed ID: 14576546
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Dynamic model of the bronchial tree.
    Ginzburg I; Elad D
    J Biomed Eng; 1993 Jul; 15(4):283-8. PubMed ID: 8361153
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Heliox does not affect gas exchange during high-frequency oscillatory ventilation if tidal volume is held constant.
    Katz AL; Gentile MA; Craig DM; Quick G; Cheifetz IM
    Crit Care Med; 2003 Jul; 31(7):2006-9. PubMed ID: 12847396
    [TBL] [Abstract][Full Text] [Related]  

  • 16. High-frequency percussive ventilation during surgical bronchial repair in a patient with one lung.
    Lucangelo U; Zin WA; Antonaglia V; Gramaticopolo S; Maffessanti M; Liguori G; Cortale M; Gullo A
    Br J Anaesth; 2006 Apr; 96(4):533-6. PubMed ID: 16490764
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Nasal high-frequency oscillation for lung carbon dioxide clearance in the newborn.
    Mukerji A; Finelli M; Belik J
    Neonatology; 2013; 103(3):161-5. PubMed ID: 23258368
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Gas exchange and lung mechanics during high frequency ventilation in the perflubron-treated lung.
    Wolf GK; Sheeran P; Heitz D; Thompson JE; Arnold JH
    Pediatr Crit Care Med; 2008 Nov; 9(6):641-6. PubMed ID: 18838935
    [TBL] [Abstract][Full Text] [Related]  

  • 19. O2 uptake and CO2 elimination during mechanical ventilation with high frequency oscillation.
    Kurata T; Ohta Y; Kondo T; Kuwahira I; Hayashi Y
    Tokai J Exp Clin Med; 1991 Jul; 16(2):133-43. PubMed ID: 1780914
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Intraoperative application of high frequency ventilation in thoracic surgery.
    Ratzenhofer-Komenda B; Prause G; Offner A; Smolle-Jüttner FM
    Acta Anaesthesiol Scand Suppl; 1996; 109():149-53. PubMed ID: 8901989
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 5.