These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
179 related articles for article (PubMed ID: 34081360)
1. Retentive Forces of Removable Partial Denture Clasp Assemblies Made from Polyaryletherketone and Cobalt-Chromium: A Comparative Study. Gentz FI; Brooks DI; Liacouras PC; Petrich A; Hamlin CM; Ellert DO; Ye L J Prosthodont; 2022 Apr; 31(4):299-304. PubMed ID: 34081360 [TBL] [Abstract][Full Text] [Related]
2. Retention and fatigue performance of modified polyetheretherketone clasps for removable prosthesis. Luo Y; Qiu L; Geng M; Zhang W J Mech Behav Biomed Mater; 2024 Jun; 154():106539. PubMed ID: 38598917 [TBL] [Abstract][Full Text] [Related]
3. In vitro study of optimal removable partial denture clasp design made from novel high-performance polyetherketoneketone. Peng PW; Chen MS; Peng TY; Huang PC; Nikawa H; Lee WF J Prosthodont Res; 2024 Jul; 68(3):466-473. PubMed ID: 38220161 [TBL] [Abstract][Full Text] [Related]
4. Deformation and retentive force following in vitro cyclic fatigue of cobalt-chrome and aryl ketone polymer (AKP) clasps. Marie A; Keeling A; Hyde TP; Nattress BR; Pavitt S; Murphy RJ; Shary TJ; Dillon S; Osnes C; Wood DJ Dent Mater; 2019 Jun; 35(6):e113-e121. PubMed ID: 30948229 [TBL] [Abstract][Full Text] [Related]
5. Fitness and retentive force of cobalt-chromium alloy clasps fabricated with repeated laser sintering and milling. Torii M; Nakata T; Takahashi K; Kawamura N; Shimpo H; Ohkubo C J Prosthodont Res; 2018 Jul; 62(3):342-346. PubMed ID: 29428170 [TBL] [Abstract][Full Text] [Related]
6. Comparative analysis of the retention force and deformation of PEEK and PEKK removable partial denture clasps with different thicknesses and undercut depths. Lee WF; Chen MS; Peng TY; Huang PC; Nikawa H; Peng PW J Prosthet Dent; 2024 Feb; 131(2):291.e1-291.e9. PubMed ID: 38057199 [TBL] [Abstract][Full Text] [Related]
7. Comparison of cast Ti-Ni alloy clasp retention with conventional removable partial denture clasps. Kim D; Park C; Yi Y; Cho L J Prosthet Dent; 2004 Apr; 91(4):374-82. PubMed ID: 15116040 [TBL] [Abstract][Full Text] [Related]
8. Retentive forces and fatigue resistance of thermoplastic resin clasps. Tannous F; Steiner M; Shahin R; Kern M Dent Mater; 2012 Mar; 28(3):273-8. PubMed ID: 22130464 [TBL] [Abstract][Full Text] [Related]
9. [Finite element analyses of retention of removable partial denture circumferential clasps manufactured by selective laser melting]. Ma KN; Chen H; Shen YR; Zhou YS; Wang Y; Sun YC Beijing Da Xue Xue Bao Yi Xue Ban; 2022 Feb; 54(1):105-112. PubMed ID: 35165476 [TBL] [Abstract][Full Text] [Related]
13. An in vitro comparison of retentive force and deformation of acetal resin and cobalt-chromium clasps. Arda T; Arikan A J Prosthet Dent; 2005 Sep; 94(3):267-74. PubMed ID: 16126079 [TBL] [Abstract][Full Text] [Related]
14. Internal porosities, retentive force, and survival of cobalt-chromium alloy clasps fabricated by selective laser-sintering. Schweiger J; Güth JF; Erdelt KJ; Edelhoff D; Schubert O J Prosthodont Res; 2020 Apr; 64(2):210-216. PubMed ID: 31680054 [TBL] [Abstract][Full Text] [Related]
15. Fitness accuracy and retentive forces of additive manufactured titanium clasp. Takahashi K; Torii M; Nakata T; Kawamura N; Shimpo H; Ohkubo C J Prosthodont Res; 2020 Oct; 64(4):468-477. PubMed ID: 32063534 [TBL] [Abstract][Full Text] [Related]
16. Retentive force and fitness accuracy of cobalt-chrome alloy clasps for removable partial denture fabricated with SLM technique. Zhang M; Gan N; Qian H; Jiao T J Prosthodont Res; 2022 Jul; 66(3):459-465. PubMed ID: 34615841 [TBL] [Abstract][Full Text] [Related]
17. In vitro Assessment of Clasps of Cobalt-Chromium and Nickel-titanium Alloys in Removable Prosthesis. Kola MZ; Raghav D; Kumar P; Alqahtani F; Murayshed MS; Bhagat TV J Contemp Dent Pract; 2016 Mar; 17(3):253-7. PubMed ID: 27207207 [TBL] [Abstract][Full Text] [Related]
18. Retention force of polyetheretherketone and cobalt-chrome-molybdenum removable dental prosthesis clasps after artificial aging. Mayinger F; Micovic D; Schleich A; Roos M; Eichberger M; Stawarczyk B Clin Oral Investig; 2021 May; 25(5):3141-3149. PubMed ID: 33064206 [TBL] [Abstract][Full Text] [Related]
19. Finite element analysis in defining the optimal shape and safety factor of retentive clasp arms of a removable partial denture. Sćepanović M; Tihacek-Sojić L; Tasić M; Mitrović R; Todorović A; Trifković B Vojnosanit Pregl; 2013 Nov; 70(11):999-1005. PubMed ID: 24397193 [TBL] [Abstract][Full Text] [Related]
20. Is the high-performance thermoplastic polyetheretherketone indicated as a clasp material for removable dental prostheses? Micovic D; Mayinger F; Bauer S; Roos M; Eichberger M; Stawarczyk B Clin Oral Investig; 2021 May; 25(5):2859-2866. PubMed ID: 33026523 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]