472 related articles for article (PubMed ID: 34082799)
21. A semi-automated, isolation-free, high-throughput SARS-CoV-2 reverse transcriptase (RT) loop-mediated isothermal amplification (LAMP) test.
Schmidt J; Berghaus S; Blessing F; Wenzel F; Herbeck H; Blessing J; Schierack P; Rödiger S; Roggenbuck D
Sci Rep; 2021 Nov; 11(1):21385. PubMed ID: 34725400
[TBL] [Abstract][Full Text] [Related]
22. Comparative analysis of loop-mediated isothermal amplification (LAMP)-based assays for rapid detection of SARS-CoV-2 genes.
Urrutia-Cabrera D; Liou RH; Wang JH; Chan J; Hung SS; Hewitt AW; Martin KR; Edwards TL; Kwan P; Wong RC
Sci Rep; 2021 Nov; 11(1):22493. PubMed ID: 34795308
[TBL] [Abstract][Full Text] [Related]
23. Development and Validation of a Novel COVID-19 nsp8 One-Tube RT-LAMP-CRISPR Assay for SARS-CoV-2 Diagnosis.
Yip CC; Sridhar S; Chan WM; Ip JD; Chu AW; Leung KH; Cheng VC; Yuen KY; To KK
Microbiol Spectr; 2022 Dec; 10(6):e0196222. PubMed ID: 36445095
[TBL] [Abstract][Full Text] [Related]
24. Development and Clinical Application of a Rapid and Sensitive Loop-Mediated Isothermal Amplification Test for SARS-CoV-2 Infection.
Hu X; Deng Q; Li J; Chen J; Wang Z; Zhang X; Fang Z; Li H; Zhao Y; Yu P; Li W; Wang X; Li S; Zhang L; Hou T
mSphere; 2020 Aug; 5(4):. PubMed ID: 32848011
[TBL] [Abstract][Full Text] [Related]
25. Starting from scratch: Step-by-step development of diagnostic tests for SARS-CoV-2 detection by RT-LAMP.
Tapia-Sidas DA; Vargas-Hernández BY; Ramírez-Pool JA; Núñez-Muñoz LA; Calderón-Pérez B; González-González R; Brieba LG; Lira-Carmona R; Ferat-Osorio E; López-Macías C; Ruiz-Medrano R; Xoconostle-Cázares B
PLoS One; 2023; 18(1):e0279681. PubMed ID: 36701313
[TBL] [Abstract][Full Text] [Related]
26. Loop-mediated isothermal amplification for the detection of SARS-CoV-2 in saliva.
Janíková M; Hodosy J; Boor P; Klempa B; Celec P
Microb Biotechnol; 2021 Jan; 14(1):307-316. PubMed ID: 33497538
[TBL] [Abstract][Full Text] [Related]
27. Development of a RT-LAMP assay for detection of SARS-CoV-2.
Nandi SS; Lambe UP; Sawant SA; Gohil T; Deshpande J
Indian J Med Res; 2022 Jan; 155(1):148-155. PubMed ID: 35313427
[TBL] [Abstract][Full Text] [Related]
28. A novel RdRp-based colorimetric RT-LAMP assay for rapid and sensitive detection of SARS-CoV-2 in clinical and sewage samples from Pakistan.
Haque MFU; Bukhari SS; Ejaz R; Zaman FU; Sreejith KR; Rashid N; Umer M; Shahzad N
Virus Res; 2021 Sep; 302():198484. PubMed ID: 34146608
[TBL] [Abstract][Full Text] [Related]
29. Rapid and Visual Detection of SARS-CoV-2 Using Multiplex Reverse Transcription Loop-Mediated Isothermal Amplification Linked With Gold Nanoparticle-Based Lateral Flow Biosensor.
Chen X; Zhou Q; Li S; Yan H; Chang B; Wang Y; Dong S
Front Cell Infect Microbiol; 2021; 11():581239. PubMed ID: 34336708
[TBL] [Abstract][Full Text] [Related]
30. Single- and Two-Stage, Closed-Tube, Point-of-Care, Molecular Detection of SARS-CoV-2.
Song J; El-Tholoth M; Li Y; Graham-Wooten J; Liang Y; Li J; Li W; Weiss SR; Collman RG; Bau HH
Anal Chem; 2021 Sep; 93(38):13063-13071. PubMed ID: 34541844
[TBL] [Abstract][Full Text] [Related]
31. Molecular Beacons Allow Specific RT-LAMP Detection of B.1.1.7 Variant SARS-CoV-2.
Sherrill-Mix S; Van Duyne GD; Bushman FD
J Biomol Tech; 2021 Sep; 32(3):98-101. PubMed ID: 35027867
[TBL] [Abstract][Full Text] [Related]
32. A colorimetric reverse transcription-loop mediated isothermal amplification (RT-LAMP) method for the rapid detection of SARS-CoV-2 in Thailand.
Bhakdeenuan P; Bunchoo S; Klayut K; Srisungngam S; Suphan O; Kongthap I; Suphankong S; Phetsuksiri B; Uppapong B; Rudeeaneksin J
Trop Biomed; 2024 Mar; 41(1):64-69. PubMed ID: 38852135
[TBL] [Abstract][Full Text] [Related]
33. Sample-to-answer, extraction-free, real-time RT-LAMP test for SARS-CoV-2 in nasopharyngeal, nasal, and saliva samples: Implications and use for surveillance testing.
Kundrod KA; Natoli ME; Chang MM; Smith CA; Paul S; Ogoe D; Goh C; Santhanaraj A; Price A; Eldin KW; Patel KP; Baker E; Schmeler KM; Richards-Kortum R
PLoS One; 2022; 17(2):e0264130. PubMed ID: 35213596
[TBL] [Abstract][Full Text] [Related]
34. Clinical Evaluation of Self-Collected Saliva by Quantitative Reverse Transcription-PCR (RT-qPCR), Direct RT-qPCR, Reverse Transcription-Loop-Mediated Isothermal Amplification, and a Rapid Antigen Test To Diagnose COVID-19.
Nagura-Ikeda M; Imai K; Tabata S; Miyoshi K; Murahara N; Mizuno T; Horiuchi M; Kato K; Imoto Y; Iwata M; Mimura S; Ito T; Tamura K; Kato Y
J Clin Microbiol; 2020 Aug; 58(9):. PubMed ID: 32636214
[TBL] [Abstract][Full Text] [Related]
35. Optimization and Clinical Evaluation of a Multi-Target Loop-Mediated Isothermal Amplification Assay for the Detection of SARS-CoV-2 in Nasopharyngeal Samples.
Roumani F; Azinheiro S; Sousa H; Sousa A; Timóteo M; Varandas T; Fonseca-Silva D; Baldaque I; Carvalho J; Prado M; Garrido-Maestu A
Viruses; 2021 May; 13(5):. PubMed ID: 34069710
[TBL] [Abstract][Full Text] [Related]
36. PD-LAMP smartphone detection of SARS-CoV-2 on chip.
Colbert AJ; Lee DH; Clayton KN; Wereley ST; Linnes JC; Kinzer-Ursem TL
Anal Chim Acta; 2022 Apr; 1203():339702. PubMed ID: 35361434
[TBL] [Abstract][Full Text] [Related]
37. Development and clinical application of loop-mediated isothermal amplification combined with lateral flow assay for rapid diagnosis of SARS-CoV-2.
Tang J; Zhu J; Wang J; Qian H; Liu Z; Wang R; Cai Q; Fang Y; Huang W
BMC Infect Dis; 2024 Jan; 24(1):81. PubMed ID: 38225546
[TBL] [Abstract][Full Text] [Related]
38. Accessible LAMP-Enabled Rapid Test (ALERT) for Detecting SARS-CoV-2.
Bektaş A; Covington MF; Aidelberg G; Arce A; Matute T; Núñez I; Walsh J; Boutboul D; Delaugerre C; Lindner AB; Federici F; Jayaprakash AD
Viruses; 2021 Apr; 13(5):. PubMed ID: 33922716
[TBL] [Abstract][Full Text] [Related]
39. Detection of SARS-CoV-2 RNA by a Multiplex Reverse-Transcription Loop-Mediated Isothermal Amplification Coupled with Melting Curves Analysis.
Oscorbin IP; Shevelev GY; Pronyaeva KA; Stepanov AA; Shamovskaya DV; Mishukova OV; Pyshnyi DV; Filipenko ML
Int J Mol Sci; 2021 May; 22(11):. PubMed ID: 34072209
[TBL] [Abstract][Full Text] [Related]
40. Automated sample-to-answer centrifugal microfluidic system for rapid molecular diagnostics of SARS-CoV-2.
Malic L; Brassard D; Da Fonte D; Nassif C; Mounier M; Ponton A; Geissler M; Shiu M; Morton KJ; Veres T
Lab Chip; 2022 Aug; 22(17):3157-3171. PubMed ID: 35670202
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]