These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

78 related articles for article (PubMed ID: 341018)

  • 1. The biologic and physical criteria for suture selection in cataract surgery.
    Blaydes JE; Salthouse TN
    Ophthalmic Surg; 1977 Dec; 8(6):66-71. PubMed ID: 341018
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The evaluation of 7-0 Polyglactin 910 suture in cataract surgery.
    Blaydes JE
    Ophthalmic Surg; 1975; 6(4):99-104. PubMed ID: 1107925
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparative evaluation of coated and uncoated polyglactin 910 in cataract and muscle surgery.
    Blaydes JE; Berry J
    Ophthalmic Surg; 1980 Nov; 11(11):790-3. PubMed ID: 7005799
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Reabsorbable polyglactin sutures. Clinical and experimental studies (author's transl)].
    Hamard H; Pouliquen Y; Bernard JA; Caumon C; Chevallier C; Marsault M; Sotton J; Vidal R
    Arch Ophtalmol (Paris); 1977; 37(10):583-96. PubMed ID: 146470
    [TBL] [Abstract][Full Text] [Related]  

  • 5. An evaluation of 8-0 polyglycolic acid braided synthetic absorbable suture in cataract surgery.
    Blaydes JE
    Ann Ophthalmol; 1979 Jun; 11(6):963-5. PubMed ID: 496189
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Laboratory and clinical evaluation of a new synthetic absorbable suture for ophthalmic surgery.
    Dunlap WA; Purnell WD; McPherson SD
    Adv Ophthalmol; 1976; 33():49-61. PubMed ID: 790910
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of an improved suture for cataract surgery.
    Sherman SE
    Ann Ophthalmol; 1979 Feb; 11(2):269-71. PubMed ID: 434745
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Use of absorbable monofilament running sutures during cataract extraction (author's transl)].
    Cotineau J; Lepifre M; Sorato M; Cardeaud JP; Voillot C
    J Fr Ophtalmol; 1981; 4(6-7):483-6. PubMed ID: 7028851
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of absorbable suture materials in biliary tract surgery.
    Sugimachi K; Sufian S; Weiss MJ; Pavlides CA; Matsumoto T
    Int Surg; 1978 Mar; 63(3):135-9. PubMed ID: 415997
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A new synthetic monofilament absorbable suture made from polytrimethylene carbonate.
    Katz AR; Mukherjee DP; Kaganov AL; Gordon S
    Surg Gynecol Obstet; 1985 Sep; 161(3):213-22. PubMed ID: 3898441
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An evaluation of 8-0 Polyglactin 910 synthetic absorbable suture in cataract surgery.
    Blaydes JE
    Ophthalmic Surg; 1976; 7(2):55-61. PubMed ID: 934601
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A comparative evaluation of 9-0 monofilament and 9-0 braid polyglactin 910 in cataract surgery (intracapsular, extracapsular, and phacoemulsification).
    Blaydes JE; Berry J
    Ophthalmic Surg; 1979 Dec; 10(12):49-54. PubMed ID: 523064
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Use of an absorbable suture in cataract surgery].
    Bec P; Arné JL; Mathis A; Calvet JM; Brunerie M
    Bull Soc Ophtalmol Fr; 1982 Apr; 82(4):539-41. PubMed ID: 7105352
    [No Abstract]   [Full Text] [Related]  

  • 14. Cataract extraction without a conjunctival flap.
    Weene LE
    Ann Ophthalmol; 1978 Apr; 10(4):513-9. PubMed ID: 354460
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of DEXON suture in cataract surgery: a study using a finer gauge material.
    Sherman SE
    Ann Ophthalmol; 1977 Sep; 9(9):1170-1. PubMed ID: 900736
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Polydioxanone (PDS), a novel monofilament synthetic absorbable suture.
    Ray JA; Doddi N; Regula D; Williams JA; Melveger A
    Surg Gynecol Obstet; 1981 Oct; 153(4):497-507. PubMed ID: 6792722
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Tendon sutures with a new monofilament synthetic absorbable suture material (PDS-suture of 6-0 strength). Results of animal experiments].
    Albers W; Geldmacher J; Giedl H; Beyer W
    Chirurg; 1982 Mar; 53(3):168-71. PubMed ID: 6802585
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of dexon suture in cataract surgery.
    Sherman SE
    Eye Ear Nose Throat Mon; 1976 Feb; 55(2):46-7. PubMed ID: 1245212
    [No Abstract]   [Full Text] [Related]  

  • 19. Commonly used suture materials in skin surgery.
    Moy RL; Lee A; Zalka A
    Am Fam Physician; 1991 Dec; 44(6):2123-8. PubMed ID: 1746393
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of tissue reaction to nylon and prolene sutures in rabbit iris and cornea.
    Kelly SE; Ehlers J; Llovera I; Troutman RC
    Ophthalmic Surg; 1975; 6(4):105-10. PubMed ID: 1107923
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.