These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

130 related articles for article (PubMed ID: 34111034)

  • 1. High Peak Inspiratory Pressures After a Change of Heat and Moisture Exchangers: A Case Series.
    Dewasurendra AM; McHugh SM
    A A Pract; 2021 Jun; 15(6):e01483. PubMed ID: 34111034
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Changing a hydrophobic heat and moisture exchanger after 48 hours rather than 24 hours: a clinical and microbiological evaluation.
    Boisson C; Viviand X; Arnaud S; Thomachot L; Miliani Y; Martin C
    Intensive Care Med; 1999 Nov; 25(11):1237-43. PubMed ID: 10654207
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Changing heat and moisture exchangers after 96 hours rather than after 24 hours: a clinical and microbiological evaluation.
    Thomachot L; Boisson C; Arnaud S; Michelet P; Cambon S; Martin C
    Crit Care Med; 2000 Mar; 28(3):714-20. PubMed ID: 10752820
    [TBL] [Abstract][Full Text] [Related]  

  • 4. In vitro evaluation of heat and moisture exchangers designed for spontaneously breathing tracheostomized patients.
    Brusasco C; Corradi F; Vargas M; Bona M; Bruno F; Marsili M; Simonassi F; Santori G; Severgnini P; Kacmarek RM; Pelosi P
    Respir Care; 2013 Nov; 58(11):1878-85. PubMed ID: 23674812
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Efficiency and safety of mechanical ventilation with a heat and moisture exchanger changed only once a week.
    Ricard JD; Le Mière E; Markowicz P; Lasry S; Saumon G; Djedaïni K; Coste F; Dreyfuss D
    Am J Respir Crit Care Med; 2000 Jan; 161(1):104-9. PubMed ID: 10619805
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of Heat Moisture Exchanger on Aerosol Drug Delivery and Airway Resistance in Simulated Ventilator-Dependent Adults Using Jet and Mesh Nebulizers.
    Ari A; Dang T; Al Enazi FH; Alqahtani MM; Alkhathami A; Qoutah R; Almamary AS; Fink JB
    J Aerosol Med Pulm Drug Deliv; 2018 Feb; 31(1):42-48. PubMed ID: 28829202
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effects of Heat and Moisture Exchangers and Exhaled Humidity on Aerosol Deposition in a Simulated Ventilator-Dependent Adult Lung Model.
    Ari A; Alwadeai KS; Fink JB
    Respir Care; 2017 May; 62(5):538-543. PubMed ID: 28270542
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Devices used to humidify respired gases.
    Rathgeber J
    Respir Care Clin N Am; 2006 Jun; 12(2):165-82. PubMed ID: 16828689
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of resistance in 8 different heat-and-moisture exchangers: effects of saturation and flow rate/profile.
    Lucato JJ; Tucci MR; Schettino GP; Adams AB; Fu C; Forti G; de Carvalho CR; de Souza R
    Respir Care; 2005 May; 50(5):636-43. PubMed ID: 15871758
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Linear versus Turbulent Airflow Tracheostomy Heat and Moisture Exchangers: A Crossover Study.
    Shikani AH; Rohayem Z; D'Adamo CR; Miller AC
    Laryngoscope; 2023 Dec; 133(12):3422-3428. PubMed ID: 37289035
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Air conditioning with a high-performance HME (heat and moisture exchanger)--an effective and economical alternative to active humidifiers in ventilated patients. A prospective and randomized clinical study].
    Rathgeber J; Henze D; Züchner K
    Anaesthesist; 1996 Jun; 45(6):518-25. PubMed ID: 8767565
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The physiological rationale of heat and moisture exchangers in post-laryngectomy pulmonary rehabilitation: a review.
    Zuur JK; Muller SH; de Jongh FH; van Zandwijk N; Hilgers FJ
    Eur Arch Otorhinolaryngol; 2006 Jan; 263(1):1-8. PubMed ID: 16001247
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Is reduction of intraoperative heat loss and management of hypothermic patients with anesthetic gas climate control advisable? Heat and humidity exchangers vs. active humidifiers ina functional lung model].
    Rathgeber J; Weyland W; Bettka T; Züchner K; Kettler D
    Anaesthesist; 1996 Sep; 45(9):807-13. PubMed ID: 8967598
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Heat and moisture exchangers for conditioning of inspired air of intubated patients in intensive care. The humidification properties of passive air exchangers under clinical conditions].
    Rathgeber J; Züchner K; Kietzmann D; Weyland W
    Anaesthesist; 1995 Apr; 44(4):274-83. PubMed ID: 7785756
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparing two heat and moisture exchangers with one vaporizing humidifier in patients with minute ventilation greater than 10 L/min.
    Martin C; Thomachot L; Quinio B; Viviand X; Albanese J
    Chest; 1995 May; 107(5):1411-5. PubMed ID: 7750340
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Understanding and predicting the performance of passive heat and moisture exchangers using a numerical model.
    Leemans M; van Alphen MJA; Vallenduuk W; Dirven R; van den Brekel MWM; Muller SH
    Head Neck; 2023 Apr; 45(4):993-1005. PubMed ID: 36811302
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The simultaneous use of a heat and moisture exchanger and a heated humidifier causes critical airway occlusion in less than 24 hours.
    Doyle A; Mariyaselvam M; Wijewardena G; English N; Gent E; Young P
    J Crit Care; 2015 Aug; 30(4):863.e1-3. PubMed ID: 25937239
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Use of heat and moisture exchanging (HME) filters in mechanically ventilated ICU patients: influence on airway flow-resistance.
    Chiaranda M; Verona L; Pinamonti O; Dominioni L; Minoja G; Conti G
    Intensive Care Med; 1993; 19(8):462-6. PubMed ID: 8294629
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluating humidity recovery efficiency of currently available heat and moisture exchangers: a respiratory system model study.
    Lucato JJ; Adams AB; Souza R; Torquato JA; Carvalho CR; Marini JJ
    Clinics (Sao Paulo); 2009; 64(6):585-90. PubMed ID: 19578664
    [TBL] [Abstract][Full Text] [Related]  

  • 20. In vitro and in vivo evaluation of a new active heat moisture exchanger.
    Chiumello D; Pelosi P; Park G; Candiani A; Bottino N; Storelli E; Severgnini P; D'Onofrio D; Gattinoni L; Chiaranda M
    Crit Care; 2004 Oct; 8(5):R281-8. PubMed ID: 15469569
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.