These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
354 related articles for article (PubMed ID: 34111855)
1. Filtering-induced time shifts in photoplethysmography pulse features measured at different body sites: the importance of filter definition and standardization. Liu H; Allen J; Khalid SG; Chen F; Zheng D Physiol Meas; 2021 Jul; 42(7):. PubMed ID: 34111855 [No Abstract] [Full Text] [Related]
2. Filtering-induced changes of pulse transmit time across different ages: a neglected concern in photoplethysmography-based cuffless blood pressure measurement. Liao S; Liu H; Lin WH; Zheng D; Chen F Front Physiol; 2023; 14():1172150. PubMed ID: 37560157 [No Abstract] [Full Text] [Related]
3. Optimal fiducial points for pulse rate variability analysis from forehead and finger photoplethysmographic signals. Peralta E; Lazaro J; Bailon R; Marozas V; Gil E Physiol Meas; 2019 Feb; 40(2):025007. PubMed ID: 30669123 [TBL] [Abstract][Full Text] [Related]
4. Estimation of phase distortions of the photoplethysmographic signal in digital IIR filtering. Lapitan DG; Rogatkin DA; Molchanova EA; Tarasov AP Sci Rep; 2024 Mar; 14(1):6546. PubMed ID: 38503856 [TBL] [Abstract][Full Text] [Related]
5. Comparison of different modulations of photoplethysmography in extracting respiratory rate: from a physiological perspective. Liu H; Chen F; Hartmann V; Khalid SG; Hughes S; Zheng D Physiol Meas; 2020 Oct; 41(9):094001. PubMed ID: 32731213 [TBL] [Abstract][Full Text] [Related]
6. Coherence between Decomposed Components of Wrist and Finger PPG Signals by Imputing Missing Features and Resolving Ambiguous Features. Tsai PY; Huang CH; Guo JW; Li YC; Wu AA; Lin HJ; Wang TD Sensors (Basel); 2021 Jun; 21(13):. PubMed ID: 34202597 [TBL] [Abstract][Full Text] [Related]
7. Effects of using different algorithms and fiducial points for the detection of interbeat intervals, and different sampling rates on the assessment of pulse rate variability from photoplethysmography. Mejía-Mejía E; May JM; Kyriacou PA Comput Methods Programs Biomed; 2022 May; 218():106724. PubMed ID: 35255373 [TBL] [Abstract][Full Text] [Related]
8. Effect of Filtering of Photoplethysmography Signals in Pulse Rate Variability Analysis Mejia-Mejia E; May JM; Kyriacou PA Annu Int Conf IEEE Eng Med Biol Soc; 2021 Nov; 2021():5500-5503. PubMed ID: 34892370 [TBL] [Abstract][Full Text] [Related]
9. Quantitative Comparison of Photoplethysmographic Waveform Characteristics: Effect of Measurement Site. Hartmann V; Liu H; Chen F; Qiu Q; Hughes S; Zheng D Front Physiol; 2019; 10():198. PubMed ID: 30890959 [No Abstract] [Full Text] [Related]
10. Impact of central hypovolemia on photoplethysmographic waveform parameters in healthy volunteers part 2: frequency domain analysis. Alian AA; Galante NJ; Stachenfeld NS; Silverman DG; Shelley KH J Clin Monit Comput; 2011 Dec; 25(6):387-96. PubMed ID: 22057245 [TBL] [Abstract][Full Text] [Related]
11. Toward Accurate Extraction of Respiratory Frequency From the Photoplethysmogram: Effect of Measurement Site. Hartmann V; Liu H; Chen F; Hong W; Hughes S; Zheng D Front Physiol; 2019; 10():732. PubMed ID: 31316390 [No Abstract] [Full Text] [Related]
12. Finger and forehead PPG signal comparison for respiratory rate estimation. Hernando A; Peláez-Coca MD; Lozano MT; Lázaro J; Gil E Physiol Meas; 2019 Sep; 40(9):095007. PubMed ID: 31422948 [TBL] [Abstract][Full Text] [Related]
13. Optimal filter characterization for photoplethysmography-based pulse rate and pulse power spectrum estimation. Cassani R; Tiwari A; Falk TH Annu Int Conf IEEE Eng Med Biol Soc; 2020 Jul; 2020():914-917. PubMed ID: 33018133 [TBL] [Abstract][Full Text] [Related]
14. Impact of the PPG Sampling Rate in the Pulse Rate Variability Indices Evaluating Several Fiducial Points in Different Pulse Waveforms. Pelaez-Coca MD; Hernando A; Lazaro J; Gil E IEEE J Biomed Health Inform; 2022 Feb; 26(2):539-549. PubMed ID: 34310329 [TBL] [Abstract][Full Text] [Related]
15. Heart-rate tuned comb filters for processing photoplethysmogram (PPG) signals in pulse oximetry. Alkhoury L; Choi JW; Wang C; Rajasekar A; Acharya S; Mahoney S; Shender BS; Hrebien L; Kam M J Clin Monit Comput; 2021 Aug; 35(4):797-813. PubMed ID: 32556842 [TBL] [Abstract][Full Text] [Related]
16. A low-complexity PPG pulse detection method for accurate estimation of the pulse rate variability (PRV) during sudden decreases in the signal amplitude. Argüello Prada EJ; Paredes Higinio A Physiol Meas; 2020 Apr; 41(3):035001. PubMed ID: 32079008 [TBL] [Abstract][Full Text] [Related]
17. Comparison of photoplethysmogram measured from wrist and finger and the effect of measurement location on pulse arrival time. Rajala S; Lindholm H; Taipalus T Physiol Meas; 2018 Aug; 39(7):075010. PubMed ID: 29794339 [TBL] [Abstract][Full Text] [Related]
18. Pulse arrival time (PAT) measurement based on arm ECG and finger PPG signals - comparison of PPG feature detection methods for PAT calculation. Rajala S; Ahmaniemi T; Lindholm H; Taipalus T Annu Int Conf IEEE Eng Med Biol Soc; 2017 Jul; 2017():250-253. PubMed ID: 29059857 [TBL] [Abstract][Full Text] [Related]
19. Systolic blood pressure estimation using PPG and ECG during physical exercise. Sun S; Bezemer R; Long X; Muehlsteff J; Aarts RM Physiol Meas; 2016 Dec; 37(12):2154-2169. PubMed ID: 27841157 [TBL] [Abstract][Full Text] [Related]