These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

241 related articles for article (PubMed ID: 34117817)

  • 41. Impact of Preexisting Left Bundle Branch Block in Transcatheter Aortic Valve Replacement Recipients.
    Fischer Q; Himbert D; Webb JG; Eltchaninoff H; Muñoz-García AJ; Tamburino C; Nombela-Franco L; Nietlispach F; Moris C; Ruel M; Dager AE; Serra V; Cheema AN; Amat-Santos IJ; de Brito FS; Ribeiro H; Abizaid A; Sarmento-Leite R; Dumont E; Barbanti M; Durand E; Alonso Briales JH; Bouleti C; Immè S; Maisano F; Del Valle R; Miguel Benitez L; García Del Blanco B; Côté M; Philippon F; Urena M; Rodés-Cabau J
    Circ Cardiovasc Interv; 2018 Nov; 11(11):e006927. PubMed ID: 30571207
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Impact of Baseline and Newly Acquired Conduction Disorders on Need for Permanent Pacemakers With 3 Consecutive Generations of Self-Expanding Transcatheter Aortic Heart Valves.
    Kroon HG; van Gils L; Ziviello F; van Wiechen M; Ooms J; Rahhab Z; El Faquir N; Maugenest AM; Kardys I; Daemen J; de Jaegere PP; Van Mieghem NM
    Cardiovasc Revasc Med; 2022 Jan; 34():40-45. PubMed ID: 33547024
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Predictors of permanent pacemaker insertion after TAVR: A systematic review and updated meta-analysis.
    Mahajan S; Gupta R; Malik AH; Mahajan P; Aedma SK; Aronow WS; Mehta SS; Lakkireddy DR
    J Cardiovasc Electrophysiol; 2021 May; 32(5):1411-1420. PubMed ID: 33682218
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Trends in the occurrence of new conduction abnormalities after transcatheter aortic valve implantation.
    van der Boon RM; Houthuizen P; Urena M; Poels TT; van Mieghem NM; Brueren GR; Altintas S; Nuis RJ; Serruys PW; van Garsse LA; van Domburg RT; Cabau JR; de Jaegere PP; Prinzen FW
    Catheter Cardiovasc Interv; 2015 Apr; 85(5):E144-52. PubMed ID: 25504891
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Predictors of permanent pacemaker implantation after ACURATE neo transcatheter heart valve implantation.
    Kim WK; Möllmann H; Walther T; Hamm CW
    Pacing Clin Electrophysiol; 2021 Feb; 44(2):410-415. PubMed ID: 33373045
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Predictors of permanent pacemaker implantation after transcatheter aortic valve implantation for aortic stenosis using Medtronic new generation self-expanding CoreValve Evolut R.
    Kaneko H; Hoelschermann F; Seifert M; Tambor G; Okamoto M; Moeller V; Neuss M; Butter C
    Heart Vessels; 2019 Feb; 34(2):360-367. PubMed ID: 30083944
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Predicting the Need For Permanent Pacing After Implantation of the Repositionable Lotus Transcatheter Aortic Valve.
    Hilling-Smith R; Kemp T; Dooley M; Rampat R; de Belder A; Hill A; Cockburn J; Trivedi U; Hildick-Smith D; Homsy M
    J Invasive Cardiol; 2020 Sep; 32(9):347-349. PubMed ID: 32653863
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Outcomes Following Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement: SWEDEHEART Observational Study.
    Rück A; Saleh N; Glaser N
    JACC Cardiovasc Interv; 2021 Oct; 14(19):2173-2181. PubMed ID: 34620397
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Predictors of conduction recovery after permanent pacemaker implantation following transcatheter aortic valve replacement.
    Phan DQ; Goitia J; Lee MS; Gupta N; Aharonian V; Mansukhani P; Moore N; Brar SS; Zadegan R
    J Interv Card Electrophysiol; 2021 Aug; 61(2):365-374. PubMed ID: 32671716
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Analysis of Conduction Abnormalities and Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement.
    Subramani S; Arora L; Krishnan S; Hanada S; Sharma A; Ramakrishna H
    J Cardiothorac Vasc Anesth; 2020 Apr; 34(4):1082-1093. PubMed ID: 31558391
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Ambulatory Rhythm Monitoring to Detect Late High-Grade Atrioventricular Block Following Transcatheter Aortic Valve Replacement.
    Ream K; Sandhu A; Valle J; Weber R; Kaizer A; Wiktor DM; Borne RT; Tumolo AZ; Kunkel M; Zipse MM; Schuller J; Tompkins C; Rosenberg M; Nguyen DT; Cleveland JC; Fullerton D; Carroll JD; Messenger J; Sauer WH; Aleong RG; Tzou WS
    J Am Coll Cardiol; 2019 May; 73(20):2538-2547. PubMed ID: 31118148
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Permanent Pacing After Transcatheter Aortic Valve Implantation: Incidence, Predictors and Evolution of Left Ventricular Function.
    Monteiro C; Ferrari ADL; Caramori PRA; Carvalho LAF; Siqueira DAA; Thiago LEKS; Perin M; Lima VC; Guérios E; Brito Junior FS
    Arq Bras Cardiol; 2017 Dec; 109(6):550-559. PubMed ID: 29185614
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Long-term pacemaker dependency and impact of pacing on mortality following transcatheter aortic valve replacement with the LOTUS valve.
    Alasti M; Rashid H; Rangasamy K; Kotschet E; Adam D; Alison J; Gooley R; Zaman S
    Catheter Cardiovasc Interv; 2018 Oct; 92(4):777-782. PubMed ID: 29314625
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Prospective comparison between three TAVR devices: ACURATE neo vs. CoreValve vs. SAPIEN XT. A single heart team experience in patients with severe aortic stenosis.
    Jatene T; Castro-Filho A; Meneguz-Moreno RA; Siqueira DA; Abizaid AAC; Ramos AIO; Arrais M; Le Bihan DCS; Barretto RBM; Moreira AC; Sousa AGMR; Eduardo Sousa J
    Catheter Cardiovasc Interv; 2017 Jul; 90(1):139-146. PubMed ID: 28029207
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Transcatheter Aortic Valve Replacement With Next-Generation Self-Expanding Devices: A Multicenter, Retrospective, Propensity-Matched Comparison of Evolut PRO Versus Acurate neo Transcatheter Heart Valves.
    Pagnesi M; Kim WK; Conradi L; Barbanti M; Stefanini GG; Zeus T; Pilgrim T; Schofer J; Zweiker D; Testa L; Taramasso M; Hildick-Smith D; Abizaid A; Wolf A; Van Mieghem NM; Sedaghat A; Wöhrle J; Khogali S; Van der Heyden JAS; Webb JG; Estévez-Loureiro R; Mylotte D; MacCarthy P; Brugaletta S; Hamm CW; Bhadra OD; Schäfer U; Costa G; Tamburino C; Cannata F; Reimers B; Veulemans V; Asami M; Windecker S; Eitan A; Schmidt A; Bianchi G; Bedogni F; Saccocci M; Maisano F; Alsanjari O; Siqueira D; Jensen CJ; Naber CK; Ziviello F; Sinning JM; Seeger J; Rottbauer W; Brouwer J; Alenezi A; Wood DA; Tzalamouras V; Regueiro A; Colombo A; Latib A
    JACC Cardiovasc Interv; 2019 Mar; 12(5):433-443. PubMed ID: 30846081
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Impact of Interventricular membranous septum length on pacemaker need with different Transcatheter aortic valve implantation systems.
    Hokken TW; van Wiechen MP; Ooms JF; El Azzouzi I; de Ronde M; Kardys I; Budde R; Daemen J; de Jaegere PP; Van Mieghem NM
    Int J Cardiol; 2021 Jun; 333():152-158. PubMed ID: 33675890
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Prevalence, predictors, and outcomes of patient prosthesis mismatch in women undergoing TAVI for severe aortic stenosis: Insights from the WIN-TAVI registry.
    Panoulas VF; Chandrasekhar J; Busi G; Ruparelia N; Zhang Z; Mehilli J; Sartori S; Lefèvre T; Presbitero P; Capranzano P; Tchetche D; Iadanza A; Sardella G; Van Mieghem NM; Meliga E; Dumonteil N; Fraccaro C; Trabattoni D; Sharma S; Ferrer-Gracia MC; Naber CK; Kievit PC; Snyder C; Sutaria N; Sen S; Malik IS; Morice MC; Nihoyannopoulos P; Petronio AS; Mehran R; Chieffo A; Mikhail GW;
    Catheter Cardiovasc Interv; 2021 Feb; 97(3):516-526. PubMed ID: 32865860
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Minimizing Permanent Pacemaker Following Repositionable Self-Expanding Transcatheter Aortic Valve Replacement.
    Jilaihawi H; Zhao Z; Du R; Staniloae C; Saric M; Neuburger PJ; Querijero M; Vainrib A; Hisamoto K; Ibrahim H; Collins T; Clark E; Pushkar I; Bamira D; Benenstein R; Tariq A; Williams M
    JACC Cardiovasc Interv; 2019 Sep; 12(18):1796-1807. PubMed ID: 31473236
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Predictors for the risk of permanent pacemaker implantation after transcatheter aortic valve replacement: A systematic review and meta-analysis.
    Wang T; Ou A; Xia P; Tian J; Wang H; Cheng Z
    J Card Surg; 2022 Feb; 37(2):377-405. PubMed ID: 34775652
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Calcium distribution patterns of the aortic valve as a risk factor for the need of permanent pacemaker implantation after transcatheter aortic valve implantation.
    Fujita B; Kütting M; Seiffert M; Scholtz S; Egron S; Prashovikj E; Börgermann J; Schäfer T; Scholtz W; Preuss R; Gummert J; Steinseifer U; Ensminger SM
    Eur Heart J Cardiovasc Imaging; 2016 Dec; 17(12):1385-1393. PubMed ID: 26758411
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 13.