These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

150 related articles for article (PubMed ID: 34134747)

  • 1. The EOS 3D imaging system reliably measures posterior tibial slope.
    Hecker A; Lerch TD; Egli RJ; Liechti EF; Klenke FM
    J Orthop Surg Res; 2021 Jun; 16(1):388. PubMed ID: 34134747
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Inter-observer reliability of measurements performed on digital long-leg standing radiographs and assessment of validity compared to 3D CT-scan.
    Boonen B; Kerens B; Schotanus MG; Emans P; Jong B; Kort NP
    Knee; 2016 Jan; 23(1):20-4. PubMed ID: 26746040
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The Intrarater and Inter-rater Reliability of Radiographic Evaluation of the Posterior Tibial Slope in Pediatric Patients.
    Fletcher AN; Liles JL; Pereira GF; Danilkowicz RM; Amendola A; Riboh JC
    J Pediatr Orthop; 2021 Jul; 41(6):e404-e410. PubMed ID: 33734200
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Measuring femoral and rotational alignment: EOS system versus computed tomography.
    Folinais D; Thelen P; Delin C; Radier C; Catonne Y; Lazennec JY
    Orthop Traumatol Surg Res; 2013 Sep; 99(5):509-16. PubMed ID: 23877073
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Usefulness of long tibial axis to measure medial tibial slope for opening wedge high tibial osteotomy.
    Akamatsu Y; Sotozawa M; Kobayashi H; Kusayama Y; Kumagai K; Saito T
    Knee Surg Sports Traumatol Arthrosc; 2016 Nov; 24(11):3661-3667. PubMed ID: 25351995
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Three-Dimensional Computed Tomography Analysis of the Posterior Tibial Slope in 100 Knees.
    Ho JPY; Merican AM; Hashim MS; Abbas AA; Chan CK; Mohamad JA
    J Arthroplasty; 2017 Oct; 32(10):3176-3183. PubMed ID: 28579444
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Clinical validation of coronal and sagittal spinal curve measurements based on three-dimensional vertebra vector parameters.
    Somoskeöy S; Tunyogi-Csapó M; Bogyó C; Illés T
    Spine J; 2012 Oct; 12(10):960-8. PubMed ID: 23018164
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Accuracy and reliability of coronal and sagittal spinal curvature data based on patient-specific three-dimensional models created by the EOS 2D/3D imaging system.
    Somoskeöy S; Tunyogi-Csapó M; Bogyó C; Illés T
    Spine J; 2012 Nov; 12(11):1052-9. PubMed ID: 23102842
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Normative 3D acetabular orientation measurements by the low-dose EOS imaging system in 102 asymptomatic subjects in standing position: Analyses by side, gender, pelvic incidence and reproducibility.
    Thelen T; Thelen P; Demezon H; Aunoble S; Le Huec JC
    Orthop Traumatol Surg Res; 2017 Apr; 103(2):209-215. PubMed ID: 28025151
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Variations in medial and lateral slope and medial proximal tibial angle.
    Meier M; Janssen D; Koeck FX; Thienpont E; Beckmann J; Best R
    Knee Surg Sports Traumatol Arthrosc; 2021 Mar; 29(3):939-946. PubMed ID: 32390118
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Radiological outcomes in a randomized trial comparing opening wedge and closing wedge techniques of high tibial osteotomy.
    Nerhus TK; Ekeland A; Solberg G; Sivertsen EA; Madsen JE; Heir S
    Knee Surg Sports Traumatol Arthrosc; 2017 Mar; 25(3):910-917. PubMed ID: 26467810
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Posterior Tibial Slope and Risk of Posterior Cruciate Ligament Injury.
    Bernhardson AS; DePhillipo NN; Daney BT; Kennedy MI; Aman ZS; LaPrade RF
    Am J Sports Med; 2019 Feb; 47(2):312-317. PubMed ID: 30640507
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Correlation between posterior tibial slope and sagittal alignment under weight-bearing conditions in osteoarthritic knees.
    Mochizuki T; Tanifuji O; Koga Y; Sato T; Kobayashi K; Watanabe S; Fujii T; Yamagiwa H; Katsumi R; Koga H; Omori G; Endo N
    PLoS One; 2018; 13(9):e0202488. PubMed ID: 30208059
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Extreme variability in posterior slope of the proximal tibia: measurements on 2395 CT scans of patients undergoing UKA?
    Nunley RM; Nam D; Johnson SR; Barnes CL
    J Arthroplasty; 2014 Aug; 29(8):1677-80. PubMed ID: 24768545
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Are navigation systems accurate enough to predict the correction angle during high tibial osteotomy? Comparison of navigation systems with 3-dimensional computed tomography and standing radiographs.
    Kyung BS; Kim JG; Jang KM; Chang M; Moon YW; Ahn JH; Wang JH
    Am J Sports Med; 2013 Oct; 41(10):2368-74. PubMed ID: 23921340
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The accuracy of intramedullary tibial guide of sagittal alignment of PCL-substituting total knee arthroplasty.
    Han HS; Kang SB; Jo CH; Kim SH; Lee JH
    Knee Surg Sports Traumatol Arthrosc; 2010 Oct; 18(10):1334-8. PubMed ID: 20454779
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Reliability of a new method for lower-extremity measurements based on stereoradiographic three-dimensional reconstruction.
    Guenoun B; Zadegan F; Aim F; Hannouche D; Nizard R
    Orthop Traumatol Surg Res; 2012 Sep; 98(5):506-13. PubMed ID: 22858107
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Skeletal landmarks for TKR implantations: evaluation of their accuracy using EOS imaging acquisition system.
    Schlatterer B; Suedhoff I; Bonnet X; Catonne Y; Maestro M; Skalli W
    Orthop Traumatol Surg Res; 2009 Feb; 95(1):2-11. PubMed ID: 19251231
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The effect of the sagittal plane osteotomy inclination on the posterior tibial slope in medial open wedge HTO: experimental study with a square column model.
    Moon SW; Ryu JY; Lee SJ; Woo SW; Park SH; Choi Y
    BMC Musculoskelet Disord; 2021 Jan; 22(1):89. PubMed ID: 33461537
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Correlation of Measurements of the Prearthritic Hip Between Plain Radiography and Computed Tomography.
    Air ME; Harrison JR; Nguyen JT; Kelly BT; Bogner EA; Moley PJ
    PM R; 2019 Feb; 11(2):158-166. PubMed ID: 29933093
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.