193 related articles for article (PubMed ID: 34142317)
1. A review of dosimetric impact of implementation of model-based dose calculation algorithms (MBDCAs) for HDR brachytherapy.
Yousif YAM; Osman AFI; Halato MA
Phys Eng Sci Med; 2021 Sep; 44(3):871-886. PubMed ID: 34142317
[TBL] [Abstract][Full Text] [Related]
2. Report of the Task Group 186 on model-based dose calculation methods in brachytherapy beyond the TG-43 formalism: current status and recommendations for clinical implementation.
Beaulieu L; Carlsson Tedgren A; Carrier JF; Davis SD; Mourtada F; Rivard MJ; Thomson RM; Verhaegen F; Wareing TA; Williamson JF
Med Phys; 2012 Oct; 39(10):6208-36. PubMed ID: 23039658
[TBL] [Abstract][Full Text] [Related]
3. A generic TG-186 shielded applicator for commissioning model-based dose calculation algorithms for high-dose-rate
Ma Y; Vijande J; Ballester F; Tedgren ÅC; Granero D; Haworth A; Mourtada F; Fonseca GP; Zourari K; Papagiannis P; Rivard MJ; Siebert FA; Sloboda RS; Smith R; Chamberland MJP; Thomson RM; Verhaegen F; Beaulieu L
Med Phys; 2017 Nov; 44(11):5961-5976. PubMed ID: 28722180
[TBL] [Abstract][Full Text] [Related]
4. A generic high-dose rate (192)Ir brachytherapy source for evaluation of model-based dose calculations beyond the TG-43 formalism.
Ballester F; Carlsson Tedgren Å; Granero D; Haworth A; Mourtada F; Fonseca GP; Zourari K; Papagiannis P; Rivard MJ; Siebert FA; Sloboda RS; Smith RL; Thomson RM; Verhaegen F; Vijande J; Ma Y; Beaulieu L
Med Phys; 2015 Jun; 42(6):3048-61. PubMed ID: 26127057
[TBL] [Abstract][Full Text] [Related]
5. Performance evaluation of a collapsed cone dose calculation algorithm for HDR Ir-192 of APBI treatments.
Terribilini D; Vitzthum V; Volken W; Frei D; Loessl K; van Veelen B; Manser P; Fix MK
Med Phys; 2017 Oct; 44(10):5475-5485. PubMed ID: 28750134
[TBL] [Abstract][Full Text] [Related]
6. A MC-based anthropomorphic test case for commissioning model-based dose calculation in interstitial breast 192-Ir HDR brachytherapy.
Peppa V; Thomson RM; Enger SA; Fonseca GP; Lee C; Lucero JNE; Mourtada F; Siebert FA; Vijande J; Papagiannis P
Med Phys; 2023 Jul; 50(7):4675-4687. PubMed ID: 37194638
[TBL] [Abstract][Full Text] [Related]
7. AAPM WGDCAB Report 372: A joint AAPM, ESTRO, ABG, and ABS report on commissioning of model-based dose calculation algorithms in brachytherapy.
Beaulieu L; Ballester F; Granero D; Tedgren ÅC; Haworth A; Lowenstein JR; Ma Y; Mourtada F; Papagiannis P; Rivard MJ; Siebert FA; Sloboda RS; Smith RL; Thomson RM; Verhaegen F; Fonseca G; Vijande J
Med Phys; 2023 Aug; 50(8):e946-e960. PubMed ID: 37427750
[TBL] [Abstract][Full Text] [Related]
8. Enhancements to commissioning techniques and quality assurance of brachytherapy treatment planning systems that use model-based dose calculation algorithms.
Rivard MJ; Beaulieu L; Mourtada F
Med Phys; 2010 Jun; 37(6):2645-58. PubMed ID: 20632576
[TBL] [Abstract][Full Text] [Related]
9. A CT-based analytical dose calculation method for HDR 192Ir brachytherapy.
Poon E; Verhaegen F
Med Phys; 2009 Sep; 36(9):3982-94. PubMed ID: 19810471
[TBL] [Abstract][Full Text] [Related]
10. Clinical transition to model-based dose calculation algorithm: A retrospective analysis of high-dose-rate tandem and ring brachytherapy of the cervix.
Jacob D; Lamberto M; DeSouza Lawrence L; Mourtada F
Brachytherapy; 2017; 16(3):624-629. PubMed ID: 28365083
[TBL] [Abstract][Full Text] [Related]
11. Limitations of the TG-43 formalism for skin high-dose-rate brachytherapy dose calculations.
Granero D; Perez-Calatayud J; Vijande J; Ballester F; Rivard MJ
Med Phys; 2014 Feb; 41(2):021703. PubMed ID: 24506594
[TBL] [Abstract][Full Text] [Related]
12. The dosimetric impact of replacing the TG-43 algorithm by model based dose calculation for liver brachytherapy.
Duque AS; Corradini S; Kamp F; Seidensticker M; Streitparth F; Kurz C; Walter F; Parodi K; Verhaegen F; Ricke J; Belka C; Fonseca GP; Landry G
Radiat Oncol; 2020 Mar; 15(1):60. PubMed ID: 32151255
[TBL] [Abstract][Full Text] [Related]
13. Dosimetric and radiobiological comparison of TG-43 and Monte Carlo calculations in
Peppa V; Pappas EP; Karaiskos P; Major T; Polgár C; Papagiannis P
Phys Med; 2016 Oct; 32(10):1245-1251. PubMed ID: 27720277
[TBL] [Abstract][Full Text] [Related]
14. Comparison of TG43 and Hounsfield Unit-based TG186 brachytherapy dose metrics in Oncentra Brachy for 100 patients receiving interstitial partial breast irradiation.
Howie A; Poder J; Brown R; Schreiber K; Bece A; Graham P; Chin YS
Brachytherapy; 2021; 20(3):655-663. PubMed ID: 33358142
[TBL] [Abstract][Full Text] [Related]
15. A user-oriented procedure for the commissioning and quality assurance testing of treatment planning system dosimetry in high-dose-rate brachytherapy.
Peppa V; Pantelis E; Pappas E; Lahanas V; Loukas C; Papagiannis P
Brachytherapy; 2016; 15(2):252-62. PubMed ID: 26727331
[TBL] [Abstract][Full Text] [Related]
16. On the experimental validation of model-based dose calculation algorithms for
Pappas EP; Zoros E; Moutsatsos A; Peppa V; Zourari K; Karaiskos P; Papagiannis P
Phys Med Biol; 2017 May; 62(10):4160-4182. PubMed ID: 28353447
[TBL] [Abstract][Full Text] [Related]
17. Dosimetric and radiobiological investigation of permanent implant prostate brachytherapy based on Monte Carlo calculations.
Haidari AM; Miksys N; Soubiran P; Cygler JE; Holmes O; Perry G; Thomson RM
Brachytherapy; 2019; 18(6):875-882. PubMed ID: 31400953
[TBL] [Abstract][Full Text] [Related]
18. Collapsed cone dose calculations for heterogeneous tissues in brachytherapy using primary and scatter separation source data.
Ahnesjö A; van Veelen B; Tedgren ÅC
Comput Methods Programs Biomed; 2017 Feb; 139():17-29. PubMed ID: 28187887
[TBL] [Abstract][Full Text] [Related]
19. Generation and comparison of 3D dosimetric reference datasets for COMS eye plaque brachytherapy using model-based dose calculations.
Fletcher EM; Ballester F; Beaulieu L; Morrison H; Poher A; Rivard MJ; Sloboda RS; Vijande J; Thomson RM
Med Phys; 2024 Jan; 51(1):694-706. PubMed ID: 37665982
[TBL] [Abstract][Full Text] [Related]
20. Impact of a commercially available model-based dose calculation algorithm on treatment planning of high-dose-rate brachytherapy in patients with cervical cancer.
Abe K; Kadoya N; Sato S; Hashimoto S; Nakajima Y; Miyasaka Y; Ito K; Umezawa R; Yamamoto T; Takahashi N; Takeda K; Jingu K
J Radiat Res; 2018 Mar; 59(2):198-206. PubMed ID: 29378024
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]