These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

138 related articles for article (PubMed ID: 34143004)

  • 1. Error analysis of channeled Stokes polarimeters.
    González-Siu LO; Bruce NC
    Appl Opt; 2021 Jun; 60(16):4511-4518. PubMed ID: 34143004
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Analysis of experimental errors in Mueller matrix channeled polarimeters.
    González-Siu LO; Bruce NC
    Appl Opt; 2021 Jun; 60(18):5456-5464. PubMed ID: 34263786
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Method to calibrate a full-Stokes polarimeter based on variable retarders.
    Montes-González I; Bruce NC; Rodríguez-Herrera OG; Rodríguez Núñez O
    Appl Opt; 2019 Aug; 58(22):5952-5957. PubMed ID: 31503911
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Design of optimal polarimeters: maximization of signal-to-noise ratio and minimization of systematic error.
    Tyo JS
    Appl Opt; 2002 Feb; 41(4):619-30. PubMed ID: 11993905
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Error analysis of single-snapshot full-Stokes division-of-aperture imaging polarimeters.
    Mu T; Zhang C; Li Q; Liang R
    Opt Express; 2015 Apr; 23(8):10822-35. PubMed ID: 25969119
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Measurement errors induced by deformation of optical axes of achromatic waveplate retarders in RRFP Stokes polarimeters.
    Dong H; Tang M; Gong Y
    Opt Express; 2012 Nov; 20(24):26649-66. PubMed ID: 23187519
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effects of typical liquid-crystal retarder errors on optimized Stokes polarimeters.
    Montes-González I; Rodríguez-Herrera OG; Avendaño-Alejo M; Bruce NC
    Appl Opt; 2022 Dec; 61(35):10458-10464. PubMed ID: 36607106
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Noise properties of uniformly-rotating RRFP Stokes polarimeters.
    Dong H; Tang M; Gong Y
    Opt Express; 2013 Apr; 21(8):9674-90. PubMed ID: 23609677
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Permitted experimental errors for optimized variable-retarder Mueller-matrix polarimeters.
    Bruce NC; López-Téllez JM; Rodríguez-Núñez O; Rodríguez-Herrera OG
    Opt Express; 2018 May; 26(11):13693-13704. PubMed ID: 29877418
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Measurement errors resulted from misalignment errors of the retarder in a rotating-retarder complete Stokes polarimeter.
    Dai H; Yan C
    Opt Express; 2014 May; 22(10):11869-83. PubMed ID: 24921308
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Calibration and data extraction in a Stokes polarimeter employing three wavelengths simultaneously.
    Aguilar-Fernández E; Bruce NC; Rodríguez-Herrera OG; Espinosa-Luna R
    Appl Opt; 2021 Jun; 60(17):5153-5160. PubMed ID: 34143087
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Dual-field imaging polarimeter using liquid crystal variable retarders.
    Pust NJ; Shaw JA
    Appl Opt; 2006 Aug; 45(22):5470-8. PubMed ID: 16855645
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Optimization and performance criteria of a Stokes polarimeter based on two variable retarders.
    Peinado A; Lizana A; Vidal J; Iemmi C; Campos J
    Opt Express; 2010 May; 18(10):9815-30. PubMed ID: 20588831
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Stokes polarimetry using analysis of the nonlinear voltage-retardance relationship for liquid-crystal variable retarders.
    López-Téllez JM; Bruce NC
    Rev Sci Instrum; 2014 Mar; 85(3):033104. PubMed ID: 24689561
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Fast and optimal broad-band Stokes/Mueller polarimeter design by the use of a genetic algorithm.
    Letnes PA; Nerbø IS; Aas LM; Ellingsen PG; Kildemo M
    Opt Express; 2010 Oct; 18(22):23095-103. PubMed ID: 21164651
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Channeled spatio-temporal Stokes polarimeters.
    Vaughn IJ; Alenin AS; Tyo JS
    Opt Lett; 2018 Jun; 43(12):2768-2771. PubMed ID: 29905684
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Accurate reconstruction of polarization parameters for channeled spectroscopic Stokes polarimeters.
    Dai H; Li D; Yang B; Zhang J
    Appl Opt; 2021 Jan; 60(1):194-200. PubMed ID: 33362090
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of two configurations of a Stokes polarimeter measuring three wavelengths simultaneously.
    Aguilar F E; Bruce NC
    Appl Opt; 2023 Jan; 62(1):83-90. PubMed ID: 36606855
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Alignment errors calibration for a channeled spectropolarimeter.
    Yang B; Ju X; Yan C; Zhang J
    Opt Express; 2016 Dec; 24(25):28923-28935. PubMed ID: 27958557
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Polarization calibration with large apertures in full field of view for a full Stokes imaging polarimeter based on liquid-crystal variable retarders.
    Zhang Y; Zhao H; Li N
    Appl Opt; 2013 Feb; 52(6):1284-92. PubMed ID: 23435001
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.