307 related articles for article (PubMed ID: 34145817)
41. Safe intramedullary fixation of displaced midshaft clavicle fractures with 2.5mm Kirschner wires - technique description and a two-part versus multifragmentary fracture fixation outcome comparison.
Bakota B; Chan G; Staresinic M; Rajput V; Phadnis J; Korac Z
Injury; 2017 Nov; 48 Suppl 5():S27-S33. PubMed ID: 29122118
[TBL] [Abstract][Full Text] [Related]
42. Effect of oblique headless compression screw fixation for metacarpal shaft fracture: a biomechanical in vitro study.
Chiu YC; Ho TY; Ting YN; Tsai MT; Huang HL; Hsu CE; Hsu JT
BMC Musculoskelet Disord; 2021 Feb; 22(1):146. PubMed ID: 33546670
[TBL] [Abstract][Full Text] [Related]
43. Biomechanical Comparison of 2 Methods of Intramedullary K-Wire Fixation of Transverse Metacarpal Shaft Fractures.
Hiatt SV; Begonia MT; Thiagarajan G; Hutchison RL
J Hand Surg Am; 2015 Aug; 40(8):1586-90. PubMed ID: 25980734
[TBL] [Abstract][Full Text] [Related]
44. Metacarpal Fracture Fixation with Intramedullary Screws.
George AR; Dragan Z; Abbot H; Handford C; Graham DJ; Sivakumar B
J Hand Surg Asian Pac Vol; 2024 Jun; 29(3):217-224. PubMed ID: 38726490
[No Abstract] [Full Text] [Related]
45. Retrograde Intramedullary Screw Fixation for Metacarpal Fractures: A Systematic Review.
Morway GR; Rider T; Jones CM
Hand (N Y); 2023 Jan; 18(1):67-73. PubMed ID: 33530708
[TBL] [Abstract][Full Text] [Related]
46. [MODIFIED INTRAMEDULLARY FIXATION WITH TWO Kirschner WIRES FOR EXTRA-ARTICULAR FRACTURE OF PROXIMAL PHALANGEAL BASE].
Li S; Wu K; Xie L; Chen L
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2016 Aug; 30(8):935-938. PubMed ID: 29786219
[TBL] [Abstract][Full Text] [Related]
47. Comparative study of K-wire combined with screw vs. K-wire in the treatment of AO type B3.1 phalangeal fractures.
Ma X; Wang L; Zhang X; Zhang Z; Xu Y; Lv L; Shao X
BMC Musculoskelet Disord; 2023 Jul; 24(1):591. PubMed ID: 37468856
[TBL] [Abstract][Full Text] [Related]
48. Closed intramedullary fixation for metacarpal fractures using J-shaped nail.
Itadera E; Hiwatari R; Moriya H; Ono Y
Hand Surg; 2008; 13(3):139-45. PubMed ID: 19378357
[TBL] [Abstract][Full Text] [Related]
49. Effect of a figure-of-eight cerclage wire with two Kirschner wires on fixation strength for transverse metacarpal shaft fractures: an in vitro study with artificial bone.
Chiu YC; Hsu CE; Ho TY; Ting YN; Tsai MT; Hsu JT
BMC Musculoskelet Disord; 2021 May; 22(1):431. PubMed ID: 33971840
[TBL] [Abstract][Full Text] [Related]
50. Crossed K-Wires Versus Intramedullary Headless Screw Fixation of Unstable Metacarpal Neck Fractures: A Biomechanical Study.
Beutel BG; Ayalon O; Kennedy OD; Lendhey M; Capo JT; Melamed E
Iowa Orthop J; 2018; 38():153-157. PubMed ID: 30104939
[TBL] [Abstract][Full Text] [Related]
51. Dual Antegrade Intramedullary Headless Screw Fixation for Treatment of Unstable Proximal Phalanx Fractures.
Gaspar MP; Gandhi SD; Culp RW; Kane PM
Hand (N Y); 2019 Jul; 14(4):494-499. PubMed ID: 29319352
[No Abstract] [Full Text] [Related]
52. A single antegrade intramedullary k-wire for fifth metacarpal neck fractures.
Assi C; Mansour J; Samaha C; Ajjoub S; Yammine K
Eur J Trauma Emerg Surg; 2020 Apr; 46(2):389-395. PubMed ID: 30617399
[TBL] [Abstract][Full Text] [Related]
53. Simplified internal fixation of fifth metacarpal neck fractures.
Amsallem L; Pierrart J; Bihel T; Sekri J; Lafosse T; Masmejean E; Delgrande D
Orthop Traumatol Surg Res; 2018 Apr; 104(2):257-260. PubMed ID: 29410077
[TBL] [Abstract][Full Text] [Related]
54. A comparison of intramedullary cannulated screws versus miniplates for fixation of unstable metacarpal diaphyseal fractures.
Kibar B; Cavit A; Örs A
J Hand Surg Eur Vol; 2022 Feb; 47(2):179-185. PubMed ID: 34107786
[TBL] [Abstract][Full Text] [Related]
55. Locking Plate Alone versus in Combination with Two Crossed Kirschner Wires for Fifth Metacarpal Neck Fracture.
Zhu H; Xu Z; Wei H; Zheng X
Sci Rep; 2017 Apr; 7():46109. PubMed ID: 28378776
[TBL] [Abstract][Full Text] [Related]
56. Radiographic and Clinical Assessment of Intramedullary Nail Fixation for the Treatment of Unstable Metacarpal Fractures.
Mirza A; Mirza J; Healy C; Mathew V; Lee B
Hand (N Y); 2018 Mar; 13(2):184-189. PubMed ID: 28719990
[TBL] [Abstract][Full Text] [Related]
57. Prospective Comparison of the Early Outcomes of Headless Compression Screw and Percutaneous K-Wire Fixation in Metacarpal Fractures.
Supichyangur K; Tananon T; Sripakdee SA; Chunyawongsak V
J Hand Surg Am; 2023 Sep; 48(9):950.e1-950.e9. PubMed ID: 35513963
[TBL] [Abstract][Full Text] [Related]
58. Biomechanical comparison of intramedullary screw fixation, dorsal plating and K-wire fixation for stable metacarpal shaft fractures.
Galbraith JG; Huntington LS; Borbas P; Ackland DC; Tham SK; Ek ET
J Hand Surg Eur Vol; 2022 Feb; 47(2):172-178. PubMed ID: 34018870
[TBL] [Abstract][Full Text] [Related]
59. Fractures of the neck of the fifth metacarpal bone. Medium-term results in 28 cases treated by percutaneous transverse pinning.
Potenza V; Caterini R; De Maio F; Bisicchia S; Farsetti P
Injury; 2012 Feb; 43(2):242-5. PubMed ID: 22154304
[TBL] [Abstract][Full Text] [Related]
60. Retrograde intramedullary headless compression screws for treatment of extra-articular thumb metacarpal base fractures.
Barrera-Ochoa S; Alabau-Rodriguez S; Campillo-Recio D; Esteban-Feliu I; Mir-Bullo X; Soldado F
J Hand Surg Eur Vol; 2020 Jul; 45(6):588-594. PubMed ID: 32397785
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]