These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
175 related articles for article (PubMed ID: 34145874)
1. AutoCCS: automated collision cross-section calculation software for ion mobility spectrometry-mass spectrometry. Lee JY; Bilbao A; Conant CR; Bloodsworth KJ; Orton DJ; Zhou M; Wilson JW; Zheng X; Webb IK; Li A; Hixson KK; Fjeldsted JC; Ibrahim YM; Payne SH; Jansson C; Smith RD; Metz TO Bioinformatics; 2021 Nov; 37(22):4193-4201. PubMed ID: 34145874 [TBL] [Abstract][Full Text] [Related]
2. PIXiE: an algorithm for automated ion mobility arrival time extraction and collision cross section calculation using global data association. Ma J; Casey CP; Zheng X; Ibrahim YM; Wilkins CS; Renslow RS; Thomas DG; Payne SH; Monroe ME; Smith RD; Teeguarden JG; Baker ES; Metz TO Bioinformatics; 2017 Sep; 33(17):2715-2722. PubMed ID: 28505286 [TBL] [Abstract][Full Text] [Related]
3. Evaluation of a Reference-Free Collision Cross Section Calibration Strategy for Proteomics Using SLIM-Based High-Resolution Ion Mobility Spectrometry-Mass Spectrometry. Ross DH; Lee JY; Gao Y; Hollerbach AL; Bilbao A; Shi T; Ibrahim YM; Smith RD; Zheng X J Am Soc Mass Spectrom; 2024 Jul; 35(7):1539-1549. PubMed ID: 38864778 [TBL] [Abstract][Full Text] [Related]
4. A re-calibration procedure for interoperable lipid collision cross section values measured by traveling wave ion mobility spectrometry. George AC; Schmitz-Afonso I; Marie V; Colsch B; Fenaille F; Afonso C; Loutelier-Bourhis C Anal Chim Acta; 2022 Sep; 1226():340236. PubMed ID: 36068052 [TBL] [Abstract][Full Text] [Related]
5. Elucidating the Gas-Phase Behavior of Nitazene Analog Protomers Using Structures for Lossless Ion Manipulations Ion Mobility-Orbitrap Mass Spectrometry. Hollerbach AL; Lin VS; Ibrahim YM; Ewing RG; Metz TO; Rodda KE J Am Soc Mass Spectrom; 2024 Jul; 35(7):1609-1621. PubMed ID: 38907730 [TBL] [Abstract][Full Text] [Related]
6. General Method to Obtain Collision Cross-Section Values in Multipass High-Resolution Cyclic Ion Mobility Separations. Habibi SC; Nagy G Anal Chem; 2023 May; 95(20):8028-8035. PubMed ID: 37163363 [TBL] [Abstract][Full Text] [Related]
7. Targeted glucocorticoid analysis using ion mobility-mass spectrometry (IM-MS). Neal SP; Wilson KM; Velosa DC; Chouinard CD J Mass Spectrom Adv Clin Lab; 2022 Apr; 24():50-56. PubMed ID: 35469203 [TBL] [Abstract][Full Text] [Related]
8. Interplatform comparison between three ion mobility techniques for human plasma lipid collision cross sections. George AC; Schmitz I; Rouvière F; Alves S; Colsch B; Heinisch S; Afonso C; Fenaille F; Loutelier-Bourhis C Anal Chim Acta; 2024 May; 1304():342535. PubMed ID: 38637036 [TBL] [Abstract][Full Text] [Related]
9. Metabolomics and lipidomics using traveling-wave ion mobility mass spectrometry. Paglia G; Astarita G Nat Protoc; 2017 Apr; 12(4):797-813. PubMed ID: 28301461 [TBL] [Abstract][Full Text] [Related]
10. Application of Ion Mobility Spectrometry and the Derived Collision Cross Section in the Analysis of Environmental Organic Micropollutants. Song XC; Canellas E; Dreolin N; Goshawk J; Lv M; Qu G; Nerin C; Jiang G Environ Sci Technol; 2023 Dec; 57(51):21485-21502. PubMed ID: 38091506 [TBL] [Abstract][Full Text] [Related]
11. Accurate Collisional Cross Section Measurement by Multipass Cyclic Ion Mobility Spectrometry. Xia C; Mernie E; Zaia J; Costello CE; Lin C Anal Chem; 2024 Jul; 96(29):11959-11968. PubMed ID: 38990519 [TBL] [Abstract][Full Text] [Related]
12. Lipid analysis by ion mobility spectrometry combined with mass spectrometry: A brief update with a perspective on applications in the clinical laboratory. Dubland JA J Mass Spectrom Adv Clin Lab; 2022 Jan; 23():7-13. PubMed ID: 34988541 [TBL] [Abstract][Full Text] [Related]
13. Ion mobility-mass spectrometry of complex carbohydrates: collision cross sections of sodiated N-linked glycans. Pagel K; Harvey DJ Anal Chem; 2013 May; 85(10):5138-45. PubMed ID: 23621517 [TBL] [Abstract][Full Text] [Related]
14. Assessing Collision Cross Section Calibration Strategies for Traveling Wave-Based Ion Mobility Separations in Structures for Lossless Ion Manipulations. Li A; Conant CR; Zheng X; Bloodsworth KJ; Orton DJ; Garimella SVB; Attah IK; Nagy G; Smith RD; Ibrahim YM Anal Chem; 2020 Nov; 92(22):14976-14982. PubMed ID: 33136380 [TBL] [Abstract][Full Text] [Related]
15. Using Collision Cross Section Distributions to Assess the Distribution of Collision Cross Section Values. France AP; Migas LG; Sinclair E; Bellina B; Barran PE Anal Chem; 2020 Mar; 92(6):4340-4348. PubMed ID: 32053357 [TBL] [Abstract][Full Text] [Related]
16. High-resolution ion mobility based on traveling wave structures for lossless ion manipulation resolves hidden lipid features. Reardon AR; May JC; Leaptrot KL; McLean JA Anal Bioanal Chem; 2024 Oct; 416(25):5473-5483. PubMed ID: 38935144 [TBL] [Abstract][Full Text] [Related]
17. Ion Mobility Spectrometry: Fundamental Concepts, Instrumentation, Applications, and the Road Ahead. Dodds JN; Baker ES J Am Soc Mass Spectrom; 2019 Nov; 30(11):2185-2195. PubMed ID: 31493234 [TBL] [Abstract][Full Text] [Related]
18. LC-IMS-MS Feature Finder: detecting multidimensional liquid chromatography, ion mobility and mass spectrometry features in complex datasets. Crowell KL; Slysz GW; Baker ES; LaMarche BL; Monroe ME; Ibrahim YM; Payne SH; Anderson GA; Smith RD Bioinformatics; 2013 Nov; 29(21):2804-5. PubMed ID: 24008421 [TBL] [Abstract][Full Text] [Related]
19. CIUSuite 3: Next-Generation CCS Calibration and Automated Data Analysis Tools for Gas-Phase Protein Unfolding Data. Jeon CK; Rojas Ramirez C; Makey DM; Kurulugama RT; Ruotolo BT J Am Soc Mass Spectrom; 2024 Aug; 35(8):1865-1874. PubMed ID: 38967378 [TBL] [Abstract][Full Text] [Related]
20. Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments. Ollivier S; Fanuel M; Rogniaux H; Ropartz D J Vis Exp; 2022 Jan; (179):. PubMed ID: 35129180 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]