These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 34157064)

  • 61. Comparison of retention and stability of implant-retained overdentures based upon implant number and distribution.
    Scherer MD; McGlumphy EA; Seghi RR; Campagni WV
    Int J Oral Maxillofac Implants; 2013; 28(6):1619-28. PubMed ID: 24278931
    [TBL] [Abstract][Full Text] [Related]  

  • 62. Within-subject comparison of two rigid bar designs connecting two interforaminal implants: patients' satisfaction and prosthetic results.
    Mericske-Stern R; Probst D; Fahrländer F; Schellenberg M
    Clin Implant Dent Relat Res; 2009 Sep; 11(3):228-37. PubMed ID: 18783424
    [TBL] [Abstract][Full Text] [Related]  

  • 63. Retention and load transfer characteristics of implant-retained auricular prostheses.
    Williams BH; Ochiai KT; Baba T; Caputo AA
    Int J Oral Maxillofac Implants; 2007; 22(3):366-72. PubMed ID: 17622002
    [TBL] [Abstract][Full Text] [Related]  

  • 64. Electromyographic Connectivity of Masseter Muscle with Different Retentive Attachments for Implant Overdentures in Patients with Atrophied Mandibular Ridges: A Crossover Study.
    ElSyad MA; Ibrahim AE; Nawar NHH; Belal TM
    Int J Oral Maxillofac Implants; 2019; 34(5):1213–1222. PubMed ID: 30892293
    [TBL] [Abstract][Full Text] [Related]  

  • 65. Comparison of three attachments in implant-tissue supported overdentures: an in vitro study.
    Tabatabaian F; Alaie F; Seyedan K
    J Dent (Tehran); 2010; 7(3):113-8. PubMed ID: 21998784
    [TBL] [Abstract][Full Text] [Related]  

  • 66. The influence of bar design (round versus milled bar) on prosthodontic maintenance of mandibular overdentures supported by 4 implants: a 5-year prospective study.
    Krennmair G; Krainhöfner M; Piehslinger E
    Int J Prosthodont; 2008; 21(6):514-20. PubMed ID: 19149069
    [TBL] [Abstract][Full Text] [Related]  

  • 67. A clinical trial of patient satisfaction and prosthodontic needs with ball and bar attachments for implant-retained complete overdentures: three-year results.
    MacEntee MI; Walton JN; Glick N
    J Prosthet Dent; 2005 Jan; 93(1):28-37. PubMed ID: 15623995
    [TBL] [Abstract][Full Text] [Related]  

  • 68. Resilient liner-retained overdentures seem to have a lower rate of mechanical complications than clip-retained overdentures in patients with 2 implant-supported bar-retained overdentures.
    Brignardello-Petersen R
    J Am Dent Assoc; 2017 Sep; 148(9):e125. PubMed ID: 28732583
    [No Abstract]   [Full Text] [Related]  

  • 69. Retention of prefabricated attachments for implant stabilized overdentures in the edentulous mandible: an in vitro study.
    Setz I; Lee SH; Engel E
    J Prosthet Dent; 1998 Sep; 80(3):323-9. PubMed ID: 9760365
    [TBL] [Abstract][Full Text] [Related]  

  • 70. Randomized, prospective, clinical evaluation of prosthodontic modalities for mandibular implant overdenture treatment.
    Burns DR; Unger JW; Coffey JP; Waldrop TC; Elswick RK
    J Prosthet Dent; 2011 Jul; 106(1):12-22. PubMed ID: 21723989
    [TBL] [Abstract][Full Text] [Related]  

  • 71. Satisfaction and Oral Health-Related Quality of Life of Different Attachments Used for Implant-Retained Overdentures in Subjects with Resorbed Mandibles: A Crossover Trial.
    Mahanna FF; Elsyad MA; Mourad SI; Abozaed HW
    Int J Oral Maxillofac Implants; 2020; 35(2):423-431. PubMed ID: 32142580
    [TBL] [Abstract][Full Text] [Related]  

  • 72. Does the retention system influence the stability of implant-supported maxillary overdentures? A comparison with fixed and conventional dentures.
    Michelon MMM; Posch AT; Sampaio-Filho HR; Lourenco EJV; Telles DM
    J Prosthodont Res; 2019 Jan; 63(1):47-51. PubMed ID: 30033158
    [TBL] [Abstract][Full Text] [Related]  

  • 73. The effect of denture cleansing solutions on the retention of yellow Hader clips: an in vitro study.
    Varghese RM; Masri R; Driscoll CF; Romberg E
    J Prosthodont; 2007; 16(3):165-71. PubMed ID: 17581177
    [TBL] [Abstract][Full Text] [Related]  

  • 74. Mandibular implant-supported overdentures: a prospective evaluation of the burden of prosthodontic maintenance with 3 different attachment systems.
    Payne AG; Solomons YF
    Int J Prosthodont; 2000; 13(3):246-53. PubMed ID: 11203640
    [TBL] [Abstract][Full Text] [Related]  

  • 75. Implant retained auricular prosthesis with a modified hader bar: a case report.
    Lovely M; Dathan PC; Gopal D; George BT; Chandrasekharan Nair K
    J Indian Prosthodont Soc; 2014 Jun; 14(2):187-90. PubMed ID: 24757357
    [TBL] [Abstract][Full Text] [Related]  

  • 76. [Complete overdenture retained with implants and bar-clip attachments].
    Zhao Y; Liu B; Ma X
    Hua Xi Kou Qiang Yi Xue Za Zhi; 1999 Nov; 17(4):338-40. PubMed ID: 12539380
    [TBL] [Abstract][Full Text] [Related]  

  • 77. Soft Liner/Clip Attachment for Bar-Retained Implant Overdentures: A Technical Note.
    ELsyad MA
    J Oral Implantol; 2016 Oct; 42(5):442-445. PubMed ID: 27267793
    [No Abstract]   [Full Text] [Related]  

  • 78. A comparison of stress distribution and flexion among various designs of bar attachments for implant overdentures: a three dimensional finite element analysis.
    Prakash V; D'Souza M; Adhikari R
    Indian J Dent Res; 2009; 20(1):31-6. PubMed ID: 19336857
    [TBL] [Abstract][Full Text] [Related]  

  • 79. Evidence is limited about the equivalence of bar/clip and ball/O-ring attachments in edentulous patients restored by implant overdentures.
    Radi IAW; Hossam L
    J Evid Based Dent Pract; 2021 Sep; 21(3):101578. PubMed ID: 34479664
    [TBL] [Abstract][Full Text] [Related]  

  • 80. Occlusal force transmission by overdenture attachments.
    Thayer HH; Caputo AA
    J Prosthet Dent; 1979 Mar; 41(3):266-71. PubMed ID: 368317
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.