These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

156 related articles for article (PubMed ID: 34166187)

  • 21. Transcranial cavitation detection in primates during blood-brain barrier opening--a performance assessment study.
    Wu SY; Tung YS; Marquet F; Downs M; Sanchez C; Chen C; Ferrera V; Konofagou E
    IEEE Trans Ultrason Ferroelectr Freq Control; 2014 Jun; 61(6):966-78. PubMed ID: 24859660
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Passive Cavitation Mapping by Cavitation Source Localization From Aperture-Domain Signals-Part I: Theory and Validation Through Simulations.
    Telichko AV; Lee T; Jakovljevic M; Dahl JJ
    IEEE Trans Ultrason Ferroelectr Freq Control; 2021 Apr; 68(4):1184-1197. PubMed ID: 33141665
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Blood-Brain Barrier Opening by Individualized Closed-Loop Feedback Control of Focused Ultrasound.
    Chien CY; Yang Y; Gong Y; Yue Y; Chen H
    BME Front; 2022; 2022():9867230. PubMed ID: 37850162
    [No Abstract]   [Full Text] [Related]  

  • 24. Monitoring of acoustic cavitation in microbubble-presented focused ultrasound exposure using gradient-echo MRI.
    Wu CH; Liu HL; Ho CT; Hsu PH; Fan CH; Yeh CK; Kang ST; Chen WS; Wang FN; Peng HH
    J Magn Reson Imaging; 2020 Jan; 51(1):311-318. PubMed ID: 31125166
    [TBL] [Abstract][Full Text] [Related]  

  • 25. In vivo transcranial cavitation threshold detection during ultrasound-induced blood-brain barrier opening in mice.
    Tung YS; Vlachos F; Choi JJ; Deffieux T; Selert K; Konofagou EE
    Phys Med Biol; 2010 Oct; 55(20):6141-55. PubMed ID: 20876972
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Cavitation-modulated inflammatory response following focused ultrasound blood-brain barrier opening.
    Ji R; Karakatsani ME; Burgess M; Smith M; Murillo MF; Konofagou EE
    J Control Release; 2021 Sep; 337():458-471. PubMed ID: 34324895
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Chirp- and random-based coded ultrasonic excitation for localized blood-brain barrier opening.
    Kamimura HA; Wang S; Wu SY; Karakatsani ME; Acosta C; Carneiro AA; Konofagou EE
    Phys Med Biol; 2015 Oct; 60(19):7695-712. PubMed ID: 26394091
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Static Magnetic Fields Dampen Focused Ultrasound-mediated Blood-Brain Barrier Opening.
    Yang Y; Pacia CP; Ye D; Yue Y; Chien CY; Chen H
    Radiology; 2021 Sep; 300(3):681-689. PubMed ID: 34227880
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Transcranial ultrasonic therapy based on time reversal of acoustically induced cavitation bubble signature.
    Gâteau J; Marsac L; Pernot M; Aubry JF; Tanter M; Fink M
    IEEE Trans Biomed Eng; 2010 Jan; 57(1):134-44. PubMed ID: 19770084
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Real-Time Passive Acoustic Mapping Using Sparse Matrix Multiplication.
    Kamimura HAS; Wu SY; Grondin J; Ji R; Aurup C; Zheng W; Heidmann M; Pouliopoulos AN; Konofagou EE
    IEEE Trans Ultrason Ferroelectr Freq Control; 2021 Jan; 68(1):164-177. PubMed ID: 32746182
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Feasibility of noninvasive cavitation-guided blood-brain barrier opening using focused ultrasound and microbubbles in nonhuman primates.
    Tung YS; Marquet F; Teichert T; Ferrera V; Konofagou EE
    Appl Phys Lett; 2011 Apr; 98(16):163704. PubMed ID: 21580802
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Temporal stability of lipid-shelled microbubbles during acoustically-mediated blood-brain barrier opening.
    Pouliopoulos AN; Jimenez DA; Frank A; Robertson A; Zhang L; Kline-Schoder AR; Bhaskar V; Harpale M; Caso E; Papapanou N; Anderson R; Li R; Konofagou EE
    Front Phys; 2020 May; 8():. PubMed ID: 32457896
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Comparison of Sonication Patterns and Microbubble Administration Strategies for Focused Ultrasound-Mediated Large-Volume Drug Delivery.
    Gong Y; Ye D; Chien CY; Yue Y; Chen H
    IEEE Trans Biomed Eng; 2022 Nov; 69(11):3449-3459. PubMed ID: 35476579
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Nonthermal ablation of deep brain targets: A simulation study on a large animal model.
    Top CB; White PJ; McDannold NJ
    Med Phys; 2016 Feb; 43(2):870-82. PubMed ID: 26843248
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Characterization of passive permeability after low intensity focused ultrasound mediated blood-brain barrier disruption in a preclinical model.
    Arsiwala TA; Sprowls SA; Blethen KE; Fladeland RA; Wolford CP; Kielkowski BN; Glass MJ; Wang P; Wilson O; Carpenter JS; Ranjan M; Finomore V; Rezai A; Lockman PR
    Fluids Barriers CNS; 2022 Sep; 19(1):72. PubMed ID: 36076213
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Transcranial functional ultrasound imaging of the brain using microbubble-enhanced ultrasensitive Doppler.
    Errico C; Osmanski BF; Pezet S; Couture O; Lenkei Z; Tanter M
    Neuroimage; 2016 Jan; 124(Pt A):752-761. PubMed ID: 26416649
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A High-Frequency Phased Array System for Transcranial Ultrasound Delivery in Small Animals.
    Rahimi S; Jones RM; Hynynen K
    IEEE Trans Ultrason Ferroelectr Freq Control; 2021 Jan; 68(1):127-135. PubMed ID: 32746231
    [TBL] [Abstract][Full Text] [Related]  

  • 38. A Fiber Bragg Grating-Based Sensor for Passive Cavitation Detection at MHz Frequencies.
    Jha CK; Jajoria K; Chakraborty AL; Shekhar H
    IEEE Trans Ultrason Ferroelectr Freq Control; 2022 May; 69(5):1682-1690. PubMed ID: 35320100
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Passive Cavitation Detection With a Needle Hydrophone Array.
    Jiang Z; Sujarittam K; Yildiz BI; Dickinson RJ; Choi JJ
    IEEE Trans Ultrason Ferroelectr Freq Control; 2022 Jan; 69(1):233-240. PubMed ID: 34648439
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Utilization of focused ultrasound for opening of the blood-nerve barrier.
    Umansky D; Bing C; Chu TH; Alzahrani S; Dunn JF; Pichardo S; Midha R
    Phys Med Biol; 2022 Oct; 67(20):. PubMed ID: 36055246
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.