175 related articles for article (PubMed ID: 34171072)
1. Calcium fructoborate coating of titanium-hydroxyapatite implants by chemisorption deposition improves implant osseointegration in the femur of New Zealand White rabbit experimental model.
Văruţ RM; Melinte PR; Pîrvu AS; Gîngu O; Sima G; Oancea CN; Teişanu AC; Drăgoi G; Biţă A; Manolea HO; Mitruţ I; Rogoveanu OC; Romulus IS; Neamţu J
Rom J Morphol Embryol; 2020; 61(4):1235-1247. PubMed ID: 34171072
[TBL] [Abstract][Full Text] [Related]
2. Biomechanical and morphometric analysis of hydroxyapatite-coated implants with varying crystallinity.
Chang YL; Lew D; Park JB; Keller JC
J Oral Maxillofac Surg; 1999 Sep; 57(9):1096-108; discussion 1108-9. PubMed ID: 10484111
[TBL] [Abstract][Full Text] [Related]
3. Effects of magnesium-substituted nanohydroxyapatite coating on implant osseointegration.
Zhao SF; Jiang QH; Peel S; Wang XX; He FM
Clin Oral Implants Res; 2013 Aug; 24 Suppl A100():34-41. PubMed ID: 22145854
[TBL] [Abstract][Full Text] [Related]
4. Enhanced biocompatibility and osseointegration of calcium titanate coating on titanium screws in rabbit femur.
Wang ZL; He RZ; Tu B; Cao X; He JS; Xia HS; Liang C; Zou M; Wu S; Wu ZJ; Xiong K
J Huazhong Univ Sci Technolog Med Sci; 2017 Jun; 37(3):362-370. PubMed ID: 28585129
[TBL] [Abstract][Full Text] [Related]
5. Effects of a cell adhesion molecule coating on the blasted surface of titanium implants on bone healing in the rabbit femur.
Park JW; Lee SG; Choi BJ; Suh JY
Int J Oral Maxillofac Implants; 2007; 22(4):533-41. PubMed ID: 17929513
[TBL] [Abstract][Full Text] [Related]
6. In vivo osseointegration of dental implants with an antimicrobial peptide coating.
Chen X; Zhou XC; Liu S; Wu RF; Aparicio C; Wu JY
J Mater Sci Mater Med; 2017 May; 28(5):76. PubMed ID: 28386851
[TBL] [Abstract][Full Text] [Related]
7. Short-term bone response to titanium implants coated with thin radiofrequent magnetron-sputtered hydroxyapatite in rabbits.
Mohammadi S; Esposito M; Hall J; Emanuelsson L; Krozer A; Thomsen P
Clin Implant Dent Relat Res; 2003; 5(4):241-53. PubMed ID: 15127995
[TBL] [Abstract][Full Text] [Related]
8. Examination of the bone-metal interface of titanium implants coated by the microwave plasma chemical vapor deposition method.
Rupprecht S; Bloch A; Rosiwal S; Neukam FW; Wiltfang J
Int J Oral Maxillofac Implants; 2002; 17(6):778-85. PubMed ID: 12507236
[TBL] [Abstract][Full Text] [Related]
9. Long-term bone response to titanium implants coated with thin radiofrequent magnetron-sputtered hydroxyapatite in rabbits.
Mohammadi S; Esposito M; Hall J; Emanuelsson L; Krozer A; Thomsen P
Int J Oral Maxillofac Implants; 2004; 19(4):498-509. PubMed ID: 15346746
[TBL] [Abstract][Full Text] [Related]
10. The removal torque of titanium implant inserted in rabbit femur coated with biomimetic deposited Ca-P coating.
Fuming H; Guoli Y; Xiaoxiang W; Shifang Z
J Oral Rehabil; 2008 Oct; 35(10):754-65. PubMed ID: 18466279
[TBL] [Abstract][Full Text] [Related]
11. Osseointegration evaluation of laser-deposited titanium dioxide nanoparticles on commercially pure titanium dental implants.
Azzawi ZGM; Hamad TI; Kadhim SA; Naji GA
J Mater Sci Mater Med; 2018 Jun; 29(7):96. PubMed ID: 29946975
[TBL] [Abstract][Full Text] [Related]
12. Effect of surface chemistry on the rate of osseointegration of sintered porous-surfaced Ti-6Al-4V implants.
Taché A; Gan L; Deporter D; Pilliar RM
Int J Oral Maxillofac Implants; 2004; 19(1):19-29. PubMed ID: 14982351
[TBL] [Abstract][Full Text] [Related]
13. A comparative study of the bone contact to zirconium and titanium implants after 8 weeks of implantation in rabbit femoral condyles.
AlFarraj AA; Sukumaran A; Al Amri MD; Van Oirschot AB; Jansen JA
Odontology; 2018 Jan; 106(1):37-44. PubMed ID: 28194543
[TBL] [Abstract][Full Text] [Related]
14. Histomorphometric analysis of the osseointegration of four different implant surfaces in the femoral epiphyses of rabbits.
Le Guehennec L; Goyenvalle E; Lopez-Heredia MA; Weiss P; Amouriq Y; Layrolle P
Clin Oral Implants Res; 2008 Nov; 19(11):1103-10. PubMed ID: 18983312
[TBL] [Abstract][Full Text] [Related]
15. Osseointegration of titanium scaffolds manufactured by selective laser melting in rabbit femur defect model.
Ilea A; Vrabie OG; Băbțan AM; Miclăuş V; Ruxanda F; Sárközi M; Barbu-Tudoran L; Mager V; Berce C; Boșca BA; Petrescu NB; Cadar O; Câmpian RS; Barabás R
J Mater Sci Mater Med; 2019 Feb; 30(2):26. PubMed ID: 30747343
[TBL] [Abstract][Full Text] [Related]
16. Evaluation of the osseointegration of dental implants coated with calcium carbonate: an animal study.
Liu Y; Zhou Y; Jiang T; Liang YD; Zhang Z; Wang YN
Int J Oral Sci; 2017 Sep; 9(3):133-138. PubMed ID: 28452375
[TBL] [Abstract][Full Text] [Related]
17. The effect of strontium and silicon substituted hydroxyapatite electrochemical coatings on bone ingrowth and osseointegration of selective laser sintered porous metal implants.
Mumith A; Cheong VS; Fromme P; Coathup MJ; Blunn GW
PLoS One; 2020; 15(1):e0227232. PubMed ID: 31923253
[TBL] [Abstract][Full Text] [Related]
18. Surface characteristics of titanium dental implants with improved microdesigns: An in vivo study of their osseointegration performance in goat mandible.
Mistry S; Burman S; Roy S; Maitra NJ; Roy R; Chanda A
J Biomater Appl; 2021 Feb; 35(7):799-813. PubMed ID: 32787493
[TBL] [Abstract][Full Text] [Related]
19. Effects of a hydroxyapatite coating on the stability of endosseous implants in rabbit tibiae.
Łukaszewska-Kuska M; Krawczyk P; Martyla A; Hędzelek W; Dorocka-Bobkowska B
Dent Med Probl; 2019; 56(2):123-129. PubMed ID: 31274249
[TBL] [Abstract][Full Text] [Related]
20. In Vivo Effect of Titanium Implants with Porous Zinc-Containing Coatings Prepared by Plasma Electrolytic Oxidation Method on Osseointegration in Rabbits.
He J; Feng W; Zhao BH; Zhang W; Lin Z
Int J Oral Maxillofac Implants; 2018; 33(2):298–310. PubMed ID: 29420672
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]