These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

216 related articles for article (PubMed ID: 3418049)

  • 1. Anatomy of the finger flexor tendon sheath and pulley system.
    Doyle JR
    J Hand Surg Am; 1988 Jul; 13(4):473-84. PubMed ID: 3418049
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Anatomy of the flexor tendon sheath and pulley system: a current review.
    Doyle JR
    J Hand Surg Am; 1989 Mar; 14(2 Pt 2):349-51. PubMed ID: 2732428
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The flexor synovial sheath anatomy of the little finger: a macroscopic study.
    Phillips CS; Falender R; Mass DP
    J Hand Surg Am; 1995 Jul; 20(4):636-41. PubMed ID: 7594293
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Surface markers for locating the pulleys and flexor tendon anatomy in the palm and fingers with reference to minimally invasive incisions.
    Gordon JA; Stone L; Gordon L
    J Hand Surg Am; 2012 May; 37(5):913-8. PubMed ID: 22365712
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Digital flexor tendon sheath: an anatomic study.
    Strauch B; de Moura W
    J Hand Surg Am; 1985 Nov; 10(6 Pt 1):785-9. PubMed ID: 4078260
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [The Omega "Omega" pulley plasty. A new technique to increase the diameter of the annular flexor digital pulleys].
    Bakhach J; Sentucq-Rigal J; Mouton P; Boileau R; Panconi B; Guimberteau JC
    Ann Chir Plast Esthet; 2005 Dec; 50(6):705-14. PubMed ID: 16165265
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Palmar and digital flexor tendon pulleys.
    Doyle JR
    Clin Orthop Relat Res; 2001 Feb; (383):84-96. PubMed ID: 11210973
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Mechanical analysis of the palmar aponeurosis pulley in human cadavers.
    Phillips C; Mass D
    J Hand Surg Am; 1996 Mar; 21(2):240-4. PubMed ID: 8683053
    [TBL] [Abstract][Full Text] [Related]  

  • 9. What is new in flexor tendon pulleys and the gaps between them in triphalangeal fingers of the hand?
    De Las Heras J; Simón de Blas C; Salaberri GJ; Krompas I; Olewnik L; Quinones S; García-Elías M; Sanudo JR; Aragonés P
    J Anat; 2024 Jul; 245(1):12-26. PubMed ID: 38419199
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Palmar aponeurosis pulley.
    Manske PR; Lesker PA
    J Hand Surg Am; 1983 May; 8(3):259-63. PubMed ID: 6875224
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of A3 pulley and adjacent sheath integrity on tendon excursion and bowstringing.
    Tang JB; Xie RG
    J Hand Surg Am; 2001 Sep; 26(5):855-61. PubMed ID: 11561238
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Pulleys of the tendon sheath of the flexor pollicis longus muscle].
    Schmidt HM; Fischer G
    Handchir Mikrochir Plast Chir; 1999 Nov; 31(6):362-6. PubMed ID: 10637724
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Flexor tendon grafts for pulley reconstruction - Morphological aspects.
    Fritz T; Ducommun P; Pohlemann T; Calcagni M; Tschernig T; Menger MD; Metzger W; Frueh FS
    Ann Anat; 2020 Sep; 231():151550. PubMed ID: 32512200
    [TBL] [Abstract][Full Text] [Related]  

  • 14. High-frequency ultrasonographic examination of the finger pulley system.
    Boutry N; Titécat M; Demondion X; Glaude E; Fontaine C; Cotten A
    J Ultrasound Med; 2005 Oct; 24(10):1333-9. PubMed ID: 16179615
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Connective tissue reinforcing structures of the digital tendon sheaths of the human hand].
    Knott C; Schmidt HM
    Gegenbaurs Morphol Jahrb; 1986; 132(1):1-28. PubMed ID: 3710108
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Pulley system in the fingers: normal anatomy and simulated lesions in cadavers at MR imaging, CT, and US with and without contrast material distention of the tendon sheath.
    Hauger O; Chung CB; Lektrakul N; Botte MJ; Trudell D; Boutin RD; Resnick D
    Radiology; 2000 Oct; 217(1):201-12. PubMed ID: 11012445
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The vascularization and structure of the human digital tendon sheath as related to flexor tendon function. An angiographic and histological study.
    Lundborg G; Myrhage R
    Scand J Plast Reconstr Surg; 1977; 11(3):195-203. PubMed ID: 609902
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Functional anatomy of the vagina fibrosa of the flexors of the fingers.
    Hoving EW; Hillen B
    J Hand Surg Br; 1989 Feb; 14(1):99-101. PubMed ID: 2926232
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Flexor pulley system: anatomy, injury, and management.
    Zafonte B; Rendulic D; Szabo RM
    J Hand Surg Am; 2014 Dec; 39(12):2525-32; quiz 2533. PubMed ID: 25459958
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Histology and ultrastructure of the human flexor tendon sheath.
    Cohen MJ; Kaplan L
    J Hand Surg Am; 1987 Jan; 12(1):25-9. PubMed ID: 3805639
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.