177 related articles for article (PubMed ID: 34187103)
1. Pediatric reference interval verification for endocrine and fertility hormone assays on the Abbott Alinity system.
Bohn MK; Wilson S; Hall A; Adeli K
Clin Chem Lab Med; 2021 Sep; 59(10):1680-1687. PubMed ID: 34187103
[TBL] [Abstract][Full Text] [Related]
2. Pediatric reference interval verification for common biochemical assays on the Abbott Alinity system.
Bohn MK; Wilson S; Hall A; Massamiri Y; Randell E; Adeli K
Clin Chem Lab Med; 2021 Aug; 59(9):1554-1562. PubMed ID: 34008378
[TBL] [Abstract][Full Text] [Related]
3. Pediatric reference interval verification for 17 specialized immunoassays and cancer markers on the Abbott Alinity i system in the CALIPER cohort of healthy children and adolescents.
Bohn MK; Wilson S; Schneider R; Massamiri Y; Randell EW; Adeli K
Clin Chem Lab Med; 2023 Jan; 61(1):123-132. PubMed ID: 36117243
[TBL] [Abstract][Full Text] [Related]
4. Pediatric reference interval verification for 16 biochemical markers on the Alinity ci system in the CALIPER cohort of healthy children and adolescents.
Bohn MK; Schneider R; Jung B; Adeli K
Clin Chem Lab Med; 2023 Oct; 61(11):2033-2040. PubMed ID: 37114851
[TBL] [Abstract][Full Text] [Related]
5. CLSI-based transference and verification of CALIPER pediatric reference intervals for 29 Ortho VITROS 5600 chemistry assays.
Higgins V; Truong D; Woroch A; Chan MK; Tahmasebi H; Adeli K
Clin Biochem; 2018 Mar; 53():93-103. PubMed ID: 29307782
[TBL] [Abstract][Full Text] [Related]
6. Paediatric reference intervals for 17 Roche cobas 8000 e602 immunoassays in the CALIPER cohort of healthy children and adolescents.
Bohn MK; Higgins V; Asgari S; Leung F; Hoffman B; Macri J; Adeli K
Clin Chem Lab Med; 2019 Nov; 57(12):1968-1979. PubMed ID: 31377737
[TBL] [Abstract][Full Text] [Related]
7. Pediatric reference intervals for 29 Ortho VITROS 5600 immunoassays using the CALIPER cohort of healthy children and adolescents.
Higgins V; Fung AWS; Chan MK; Macri J; Adeli K
Clin Chem Lab Med; 2018 Jan; 56(2):327-340. PubMed ID: 28723610
[TBL] [Abstract][Full Text] [Related]
8. The Canadian laboratory initiative on pediatric reference intervals: A CALIPER white paper.
Adeli K; Higgins V; Trajcevski K; White-Al Habeeb N
Crit Rev Clin Lab Sci; 2017 Sep; 54(6):358-413. PubMed ID: 29017389
[TBL] [Abstract][Full Text] [Related]
9. Pediatric reference intervals for endocrine markers in healthy children and adolescents on the Liaison XL (DiaSorin) immunoassay system.
Miller JJ; Bohn MK; Higgins V; Nichols M; Mohammed-Ali Z; Henderson T; Selvaratnam R; Sepiashvili L; Adeli K
Clin Biochem; 2023 Oct; 120():110644. PubMed ID: 37673294
[TBL] [Abstract][Full Text] [Related]
10. Pediatric reference value distributions and covariate-stratified reference intervals for 29 endocrine and special chemistry biomarkers on the Beckman Coulter Immunoassay Systems: a CALIPER study of healthy community children.
Karbasy K; Lin DC; Stoianov A; Chan MK; Bevilacqua V; Chen Y; Adeli K
Clin Chem Lab Med; 2016 Apr; 54(4):643-57. PubMed ID: 26457782
[TBL] [Abstract][Full Text] [Related]
11. Pediatric reference intervals for endocrine markers and fertility hormones in healthy children and adolescents on the Siemens Healthineers Atellica immunoassay system.
Bohn MK; Horn P; League D; Steele P; Hall A; Adeli K
Clin Chem Lab Med; 2021 Jul; 59(8):1421-1430. PubMed ID: 33957708
[TBL] [Abstract][Full Text] [Related]
12. CLSI-based transference of CALIPER pediatric reference intervals to Beckman Coulter AU biochemical assays.
Abou El Hassan M; Stoianov A; Araújo PA; Sadeghieh T; Chan MK; Chen Y; Randell E; Nieuwesteeg M; Adeli K
Clin Biochem; 2015 Nov; 48(16-17):1151-9. PubMed ID: 25979809
[TBL] [Abstract][Full Text] [Related]
13. Canadian Laboratory Initiative on Pediatric Reference Interval Database (CALIPER): pediatric reference intervals for an integrated clinical chemistry and immunoassay analyzer, Abbott ARCHITECT ci8200.
Chan MK; Seiden-Long I; Aytekin M; Quinn F; Ravalico T; Ambruster D; Adeli K
Clin Biochem; 2009 Jun; 42(9):885-91. PubMed ID: 19318027
[TBL] [Abstract][Full Text] [Related]
14. Transference of CALIPER pediatric reference intervals to biochemical assays on the Roche cobas 6000 and the Roche Modular P.
Higgins V; Chan MK; Nieuwesteeg M; Hoffman BR; Bromberg IL; Gornall D; Randell E; Adeli K
Clin Biochem; 2016 Jan; 49(1-2):139-49. PubMed ID: 26297116
[TBL] [Abstract][Full Text] [Related]
15. Comprehensive Pediatric Reference Limits for High-Sensitivity Cardiac Troponin I and NT-proBNP in the CALIPER Cohort.
Bohn MK; Adeli K
J Appl Lab Med; 2023 May; 8(3):443-456. PubMed ID: 37021828
[TBL] [Abstract][Full Text] [Related]
16. CLSI-based transference of the CALIPER database of pediatric reference intervals from Abbott to Beckman, Ortho, Roche and Siemens Clinical Chemistry Assays: direct validation using reference samples from the CALIPER cohort.
Estey MP; Cohen AH; Colantonio DA; Chan MK; Marvasti TB; Randell E; Delvin E; Cousineau J; Grey V; Greenway D; Meng QH; Jung B; Bhuiyan J; Seccombe D; Adeli K
Clin Biochem; 2013 Sep; 46(13-14):1197-219. PubMed ID: 23578738
[TBL] [Abstract][Full Text] [Related]
17. Complex biological pattern of fertility hormones in children and adolescents: a study of healthy children from the CALIPER cohort and establishment of pediatric reference intervals.
Konforte D; Shea JL; Kyriakopoulou L; Colantonio D; Cohen AH; Shaw J; Bailey D; Chan MK; Armbruster D; Adeli K
Clin Chem; 2013 Aug; 59(8):1215-27. PubMed ID: 23637248
[TBL] [Abstract][Full Text] [Related]
18. Establishing paediatric reference intervals for thyroid function tests in Croatian population on the Abbott Architect i2000.
Bokulić A; Zec I; Marijančević D; Goreta S; Požgaj Šepec M; La Grasta Sabolić L
Biochem Med (Zagreb); 2021 Oct; 31(3):030702. PubMed ID: 34393595
[TBL] [Abstract][Full Text] [Related]
19. Continuous reference curves for common hematology markers in the CALIPER cohort of healthy children and adolescents on the Sysmex XN-3000 system.
Wilson S; Bohn MK; Hall A; Higgins V; Abdelhaleem M; Adeli K
Int J Lab Hematol; 2021 Dec; 43(6):1394-1402. PubMed ID: 34333858
[TBL] [Abstract][Full Text] [Related]
20. Evaluation of analytical performance of Alinity i system on 31 measurands.
Seo JD; Song DY; Nam Y; Li C; Kim S; Lee JH; Lee K; Song J; Song SH
Pract Lab Med; 2020 Nov; 22():e00185. PubMed ID: 33204790
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]