These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

187 related articles for article (PubMed ID: 34191570)

  • 21. Catheter intervention to treat migrated temporary epicardial pacing wire into the left side of the heart.
    Sugiyama K; Koizumi N; Nishibe T; Ogino H
    Interact Cardiovasc Thorac Surg; 2018 Jul; 27(1):142-144. PubMed ID: 29529196
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Insertion and Management of Temporary Pacemakers.
    Sullivan BL; Bartels K; Hamilton N
    Semin Cardiothorac Vasc Anesth; 2016 Mar; 20(1):52-62. PubMed ID: 26134176
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Is there a correlation between late re-exploration after cardiac surgery and removal of epicardial pacemaker wires?
    Bougioukas I; Jebran AF; Grossmann M; Friedrich M; Tirilomis T; Schoendube FA; Danner BC
    J Cardiothorac Surg; 2017 Jan; 12(1):3. PubMed ID: 28122567
    [TBL] [Abstract][Full Text] [Related]  

  • 24. The formation of bronchocutaneous fistulae due to retained epicardial pacing wires: A literature review.
    Patris V; Argiriou M; Salem AL; Giakoumidakis K; Baikoussis NG; Charitos C
    Ann Card Anaesth; 2016; 19(4):683-686. PubMed ID: 27716700
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Clinical and mechanical factors associated with the removal of temporary epicardial pacemaker wires after cardiac surgery.
    Elmistekawy E; Gee YY; Une D; Lemay M; Stolarik A; Rubens FD
    J Cardiothorac Surg; 2016 Jan; 11():8. PubMed ID: 26774802
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Necessity of temporary epicardial pacing wires after surgery for congenital heart disease.
    Chauhan M; Prentice E; Zidan M; Walters HL; Delius RE; Mastropietro CW
    Ann Thorac Surg; 2014 Jun; 97(6):2148-53. PubMed ID: 24681035
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Bilateral sternobronchial fistula after coronary surgery--are the retained epicardial pacing wires responsible? A case report.
    Sakellaridis T; Argiriou M; Panagiotakopoulos V; Charitos C
    J Cardiothorac Surg; 2009 Jun; 4():26. PubMed ID: 19552802
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Temporary epicardial pacing wire placement in totally endoscopic cardiac surgery.
    Yu T; Zhang X; Huang K
    Asian Cardiovasc Thorac Ann; 2016 Jul; 24(6):613-5. PubMed ID: 27130494
    [TBL] [Abstract][Full Text] [Related]  

  • 29. eComment. Retained temporary epicardial pacing wires in cardiac surgery.
    Dimitrakakis G; Dimitrakaki IA
    Interact Cardiovasc Thorac Surg; 2012 Dec; 15(6):1051. PubMed ID: 23166218
    [No Abstract]   [Full Text] [Related]  

  • 30. Safety and image quality of cardiovascular magnetic resonance imaging in patients with retained epicardial pacing wires after heart transplantation.
    Gatterer C; Stelzmüller ME; Kammerlander A; Zuckermann A; Krššák M; Loewe C; Beitzke D
    J Cardiovasc Magn Reson; 2021 Mar; 23(1):24. PubMed ID: 33715632
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Atrioventricular sequential pacing using transesophageal atrial pacing in combination with a temporary DDD pacemaker for atrial tracking and ventricular pacing.
    Roth JV; Huertas R
    J Cardiothorac Vasc Anesth; 1995 Jun; 9(3):255-8. PubMed ID: 7669956
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Timing of removal of pacing wires following paediatric cardiac surgery.
    Jowett V; Hayes N; Sridharan S; Rees P; Macrae D
    Cardiol Young; 2007 Oct; 17(5):512-6. PubMed ID: 17868500
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Temporary epicardial pacemaker wires: significance of position and electrode type.
    Aser R; Orhan C; Niemann B; Roth P; Perepelitsa A; Attmann T; Böning A
    Thorac Cardiovasc Surg; 2014 Feb; 62(1):66-9. PubMed ID: 23034875
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Pausing With the Gauze: Inhibition of Temporary Pacemakers by Radiofrequency Scan During Cardiac Surgery.
    Williams MR; Atkinson DB; Bezzerides VJ; Yuki K; Franklin K; Casta A; Alexander ME
    Anesth Analg; 2016 Nov; 123(5):1143-1148. PubMed ID: 27644061
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Pericardial tamponade and right-to-left shunt through patent foramen ovale after epicardial pacing-wire removal.
    Saidi B; Roshanali F; Yousefnia MA; Mandegar MH
    Tex Heart Inst J; 2010; 37(5):574-5. PubMed ID: 20978573
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Is routine use of temporary epicardial pacing wires necessary after either OPCAB or conventional CABG/CPB?
    Puskas JD; Sharoni E; Williams WH; Petersen R; Duke P; Guyton RA
    Heart Surg Forum; 2003; 6(6):E103-6. PubMed ID: 14721993
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Hemodynamically optimized temporary cardiac pacing after surgery for congenital heart defects.
    Janousek J; Vojtovic P; Chaloupecký V; Hucín B; Tláskal T; Kostelka M; Reich O
    Pacing Clin Electrophysiol; 2000 Aug; 23(8):1250-9. PubMed ID: 10962747
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Feasibility of customised unipolar conversion using bipolar temporary pacing wires in patients after surgical repair of congenital heart disease.
    Peters B; Miera O; Ewert P; Yilmaz S; Berger F; Schmitt B
    Cardiol Young; 2014 Aug; 24(4):610-5. PubMed ID: 23962738
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Congenital cardiac surgery without routine placement of wires for temporary pacing.
    Fishberger SB; Rossi AF; Bolivar JM; Lopez L; Hannan RL; Burke RP
    Cardiol Young; 2008 Feb; 18(1):96-9. PubMed ID: 17977466
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Care and safety of pacemaker electrodes in intensive care and telemetry nursing units.
    Baas LS; Beery TA; Hickey CS
    Am J Crit Care; 1997 Jul; 6(4):302-11. PubMed ID: 9215428
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.