208 related articles for article (PubMed ID: 34221326)
1. Multiplexed droplet loop-mediated isothermal amplification with scorpion-shaped probes and fluorescence microscopic counting for digital quantification of virus RNAs.
Tan YL; Huang AQ; Tang LJ; Jiang JH
Chem Sci; 2021 May; 12(24):8445-8451. PubMed ID: 34221326
[TBL] [Abstract][Full Text] [Related]
2. TriD-LAMP: A pump-free microfluidic chip for duplex droplet digital loop-mediated isothermal amplification analysis.
Wu C; Liu L; Ye Z; Gong J; Hao P; Ping J; Ying Y
Anal Chim Acta; 2022 Nov; 1233():340513. PubMed ID: 36283772
[TBL] [Abstract][Full Text] [Related]
3. Droplet Encoding-Pairing Enabled Multiplexed Digital Loop-Mediated Isothermal Amplification for Simultaneous Quantitative Detection of Multiple Pathogens.
Cai D; Wang Y; Zou J; Li Z; Huang E; Ouyang X; Que Z; Luo Y; Chen Z; Jiang Y; Zhang G; Wu H; Liu D
Adv Sci (Weinh); 2023 Mar; 10(7):e2205863. PubMed ID: 36646503
[TBL] [Abstract][Full Text] [Related]
4. A microfluidic chip capable of generating and trapping emulsion droplets for digital loop-mediated isothermal amplification analysis.
Ma YD; Luo K; Chang WH; Lee GB
Lab Chip; 2018 Jan; 18(2):296-303. PubMed ID: 29188245
[TBL] [Abstract][Full Text] [Related]
5. Droplet and Microchamber-Based Digital Loop-Mediated Isothermal Amplification (dLAMP).
Yuan H; Chao Y; Shum HC
Small; 2020 Mar; 16(9):e1904469. PubMed ID: 31899592
[TBL] [Abstract][Full Text] [Related]
6. Digital Droplet Loop-Mediated Isothermal Amplification Featuring a Molecular Beacon Assay, 3D Printed Droplet Generation, and Smartphone Imaging for Sequence-Specific DNA Detection.
Hsieh SA; Shamsaei D; Eitzmann DR; Anderson JL
Anal Chem; 2022 Aug; 94(34):11949-11956. PubMed ID: 35973866
[TBL] [Abstract][Full Text] [Related]
7. An integrated and multi-functional droplet-based microfluidic platform for digital DNA amplification.
Wang Y; Zhou X; Yang Z; Xu T; Fu H; Fong CC; Sun J; Chin YR; Zhang L; Guan X; Yang M
Biosens Bioelectron; 2024 Feb; 246():115831. PubMed ID: 38008058
[TBL] [Abstract][Full Text] [Related]
8. Droplet microfluidic-based loop-mediated isothermal amplification (dLAMP) for simultaneous quantification of multiple targets.
Tan YL; Wang T; He J; Jiang JH
STAR Protoc; 2022 Jun; 3(2):101335. PubMed ID: 35496787
[TBL] [Abstract][Full Text] [Related]
9. [Digital loop-mediated isothermal amplification detection technology and its application progress].
Huang J; Li P; Shi SJ; Li YH; Xie XB
Zhonghua Yu Fang Yi Xue Za Zhi; 2021 Dec; 55(12):1518-1523. PubMed ID: 34963254
[TBL] [Abstract][Full Text] [Related]
10. Design of a Digital LAMP Detection Platform Based on Droplet Microfluidic Technology.
Jiang L; Lan X; Ren L; Yang M; Wei B; Wang Y
Micromachines (Basel); 2023 May; 14(5):. PubMed ID: 37241700
[TBL] [Abstract][Full Text] [Related]
11. Hand-Powered Microfluidics for Parallel Droplet Digital Loop-Mediated Isothermal Amplification Assays.
Yuan H; Tian J; Chao Y; Chien YS; Luo RH; Guo JY; Li S; Chou YJ; Shum HC; Chen CF
ACS Sens; 2021 Aug; 6(8):2868-2874. PubMed ID: 34156242
[TBL] [Abstract][Full Text] [Related]
12. Deep-dLAMP: Deep Learning-Enabled Polydisperse Emulsion-Based Digital Loop-Mediated Isothermal Amplification.
Chen L; Ding J; Yuan H; Chen C; Li Z
Adv Sci (Weinh); 2022 Mar; 9(9):e2105450. PubMed ID: 35072353
[TBL] [Abstract][Full Text] [Related]
13. Rotational scan digital LAMP for accurate quantitation of nucleic acids.
Jiang M; Liao P; Sun Y; Shao X; Chen Z; Fei P; Wang J; Huang Y
Lab Chip; 2021 Jun; 21(11):2265-2271. PubMed ID: 33908545
[TBL] [Abstract][Full Text] [Related]
14. Digital Sort-Enabled Counting Allows Absolute Electrical Quantification of Target Nucleic Acid.
Liu Y; Cui X; Lu R; Yang D; Ai Y; Cheow LF
ACS Sens; 2024 May; 9(5):2695-2702. PubMed ID: 38747895
[TBL] [Abstract][Full Text] [Related]
15. ddRFC: A scalable multiplexed droplet digital nucleic acid amplification test platform.
Zhang Y; Zhang P; Chen L; Kaushik A; Hu K; Wang TH
Biosens Bioelectron; 2020 Nov; 167():112499. PubMed ID: 32846271
[TBL] [Abstract][Full Text] [Related]
16. Mechanistic evaluation of the pros and cons of digital RT-LAMP for HIV-1 viral load quantification on a microfluidic device and improved efficiency via a two-step digital protocol.
Sun B; Shen F; McCalla SE; Kreutz JE; Karymov MA; Ismagilov RF
Anal Chem; 2013 Feb; 85(3):1540-6. PubMed ID: 23324061
[TBL] [Abstract][Full Text] [Related]
17. Digital LAMP in a sample self-digitization (SD) chip.
Gansen A; Herrick AM; Dimov IK; Lee LP; Chiu DT
Lab Chip; 2012 Jun; 12(12):2247-54. PubMed ID: 22399016
[TBL] [Abstract][Full Text] [Related]
18. CoID-LAMP: Color-Encoded, Intelligent Digital LAMP for Multiplex Nucleic Acid Quantification.
Wu K; Fang Q; Zhao Z; Li Z
Anal Chem; 2023 Mar; 95(11):5069-5078. PubMed ID: 36892003
[TBL] [Abstract][Full Text] [Related]
19. Agarose-Droplet-Based Digital LAMP Assay for Counting Virus DNA in Single-Particle ICP-MS.
Yin X; Chen B; He M; Hu B
Anal Chem; 2022 May; 94(17):6582-6590. PubMed ID: 35438494
[TBL] [Abstract][Full Text] [Related]
20. Absolute Quantification of H5-Subtype Avian Influenza Viruses Using Droplet Digital Loop-Mediated Isothermal Amplification.
Hu Y; Xu P; Luo J; He H; Du W
Anal Chem; 2017 Jan; 89(1):745-750. PubMed ID: 28105842
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]