These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

107 related articles for article (PubMed ID: 34224082)

  • 1. Surface dose and build-up region depth dose measurements in non-standard beams of Cyberknife and tomotherapy systems.
    Jerrin A; Ramasubramanian V
    Radiol Phys Technol; 2021 Sep; 14(3):309-317. PubMed ID: 34224082
    [TBL] [Abstract][Full Text] [Related]  

  • 2. In vivo dosimetry with optically stimulated luminescent dosimeters, OSLDs, compared to diodes; the effects of buildup cap thickness and fabrication material.
    Jursinic PA; Yahnke CJ
    Med Phys; 2011 Oct; 38(10):5432-40. PubMed ID: 21992362
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Validation of OSLD and a treatment planning system for surface dose determination in IMRT treatments.
    Zhuang AH; Olch AJ
    Med Phys; 2014 Aug; 41(8):081720. PubMed ID: 25086530
    [TBL] [Abstract][Full Text] [Related]  

  • 4. On the Use of Optically Stimulated Luminescent Dosimeter for Surface Dose Measurement during Radiotherapy.
    Yusof FH; Ung NM; Wong JH; Jong WL; Ath V; Phua VC; Heng SP; Ng KH
    PLoS One; 2015; 10(6):e0128544. PubMed ID: 26052690
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Dose response of a radiophotoluminescent glass dosimeter for TomoTherapy, CyberKnife, and flattening-filter-free linear accelerator output measurements in dosimetry audit.
    Mizuno H; Yamashita W; Okuyama H; Takase N; Tohyama N; Shimizu H; Fujita Y; Kito S; Nakaji T; Fukuda S
    Phys Med; 2021 Aug; 88():91-97. PubMed ID: 34214838
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Characterization of nanoDot optically stimulated luminescence detectors and high-sensitivity MCP-N thermoluminescent detectors in the 40-300 kVp energy range.
    Poirier Y; Kuznetsova S; Villarreal-Barajas JE
    Med Phys; 2018 Jan; 45(1):402-413. PubMed ID: 29164632
    [TBL] [Abstract][Full Text] [Related]  

  • 7. CyberKnife reference dosimetry: An assessment of the impact of evolving recommendations on correction factors and measured dose.
    Buchegger N; Grogan G; Hug B; Oliver C; Ebert M
    Med Phys; 2020 Aug; 47(8):3573-3585. PubMed ID: 32311095
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Measurement of surface dose in an MR-Linac with optically stimulated luminescence dosimeters for IMRT beam geometries.
    Lim-Reinders S; Keller BM; Sahgal A; Chugh B; Kim A
    Med Phys; 2020 Jul; 47(7):3133-3142. PubMed ID: 32302010
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Characterization of the effect of a new commercial transmission detector on radiation therapy beams.
    Cheung JP; Perez-Andujar A; Morin O
    Pract Radiat Oncol; 2017; 7(6):e559-e567. PubMed ID: 28666901
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Build-up and surface dose measurements on phantoms using micro-MOSFET in 6 and 10 MV x-ray beams and comparisons with Monte Carlo calculations.
    Xiang HF; Song JS; Chin DW; Cormack RA; Tishler RB; Makrigiorgos GM; Court LE; Chin LM
    Med Phys; 2007 Apr; 34(4):1266-73. PubMed ID: 17500458
    [TBL] [Abstract][Full Text] [Related]  

  • 11. SU-E-T-143: Effect of Physical and Virtual Wedges on the Surface Dose at Various SSD for 6 and 15 MV Photon Beam.
    Yadav G; Sinha SN; Ashokkumar S; Raman K; Mishra M; Thiyagarajan R; Yadav RS
    Med Phys; 2012 Jun; 39(6Part11):3736. PubMed ID: 28517136
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Dosimetric characterization of optically stimulated luminescence dosimeter with therapeutic photon beams for use in clinical radiotherapy measurements.
    Ponmalar R; Manickam R; Ganesh KM; Saminathan S; Raman A; Godson HF
    J Cancer Res Ther; 2017; 13(2):304-312. PubMed ID: 28643752
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of Al2O3:C optically stimulated luminescence (OSL) dosimeters for passive dosimetry of high-energy photon and electron beams in radiotherapy.
    Yukihara EG; Mardirossian G; Mirzasadeghi M; Guduru S; Ahmad S
    Med Phys; 2008 Jan; 35(1):260-9. PubMed ID: 18293581
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparative dose evaluations between XVI and OBI cone beam CT systems using Gafchromic XRQA2 film and nanoDot optical stimulated luminescence dosimeters.
    Giaddui T; Cui Y; Galvin J; Yu Y; Xiao Y
    Med Phys; 2013 Jun; 40(6):062102. PubMed ID: 23718600
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Assessment of Surface and Build-up Doses for a 6 MV Photon Beam using Parallel Plate Chamber, EBT3 Gafchromic Films, and PRIMO Monte Carlo Simulation Code.
    Mahur M; Singh M; Gurjar OP; Semwal MK
    J Biomed Phys Eng; 2022 Oct; 12(5):455-464. PubMed ID: 36313413
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A novel method for the determination of field output factors and output correction factors for small static fields for six diodes and a microdiamond detector in megavoltage photon beams.
    Casar B; Gershkevitsh E; Mendez I; Jurković S; Huq MS
    Med Phys; 2019 Feb; 46(2):944-963. PubMed ID: 30521073
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Al
    Christensen JB; Togno M; Nesteruk KP; Psoroulas S; Meer D; Weber DC; Lomax T; Yukihara EG; Safai S
    Phys Med Biol; 2021 Apr; 66(8):. PubMed ID: 33571973
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Out-of-field dose assessment for a 1.5 T MR-Linac with optically stimulated luminescence dosimeters.
    Zhang Y; Yan S; Cui Z; Wang Y; Li Z; Yin Y; Li B; Quan H; Zhu J
    Med Phys; 2021 Jul; 48(7):4027-4037. PubMed ID: 33714229
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Detector response in the buildup region of small MV fields.
    Wegener S; Herzog B; Sauer OA
    Med Phys; 2020 Mar; 47(3):1327-1339. PubMed ID: 31860128
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Determination of the KQclinfclin,Qmsr fmsr correction factors for detectors used with an 800 MU/min CyberKnife(®) system equipped with fixed collimators and a study of detector response to small photon beams using a Monte Carlo method.
    Moignier C; Huet C; Makovicka L
    Med Phys; 2014 Jul; 41(7):071702. PubMed ID: 24989371
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.