These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

121 related articles for article (PubMed ID: 34226452)

  • 1. Clinical Outcome on Comminuted Femoral Shaft Fractures in Adults Treated by Minimally Invasive Plate Osteosynthesis (MIPO) with Locking Plate.
    Hossain MZ; Roy MK; Mamun MA; Islam SI; Begum T; Minto MR; Islam MK; Alauddin M; Alam MT; Rahman MM
    Mymensingh Med J; 2021 Jul; 30(3):657-665. PubMed ID: 34226452
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Minimally invasive plate osteosynthesis (MIPO) in the treatment of the femoral shaft fracture where intramedullary nailing is not indicated.
    Apivatthakakul T; Chiewcharntanakit S
    Int Orthop; 2009 Aug; 33(4):1119-26. PubMed ID: 18597087
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The use of interfragmentary positional screw in minimally invasive plate osteosynthesis for simple distal femur fractures in elderly patients: A retrospective, single-centre pilot study.
    Chung JY; Cho JH; Kweon HJ; Song HK
    Injury; 2016 Dec; 47(12):2795-2799. PubMed ID: 27802890
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Malalignment after minimally invasive plate osteosynthesis in distal femoral fractures.
    Kim JW; Oh CW; Oh JK; Park IH; Kyung HS; Park KH; Yoon SD; Kim SM
    Injury; 2017 Mar; 48(3):751-757. PubMed ID: 28093251
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison between antegrade intramedullary nailing (IMN), open reduction plate osteosynthesis (ORPO) and minimally invasive plate osteosynthesis (MIPO) in treatment of humerus diaphyseal fractures.
    Kulkarni VS; Kulkarni MS; Kulkarni GS; Goyal V; Kulkarni MG
    Injury; 2017 Aug; 48 Suppl 2():S8-S13. PubMed ID: 28802426
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Minimally invasive plate osteosynthesis of subtrochanteric femur fractures with a locking plate: a prospective series of 20 fractures.
    Oh CW; Kim JJ; Byun YS; Oh JK; Kim JW; Kim SY; Park BC; Lee HJ
    Arch Orthop Trauma Surg; 2009 Dec; 129(12):1659-65. PubMed ID: 19169695
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Treatment of intraarticular comminuted supracondylar femoral fractures by indirect plate osteosynthesis].
    Ağuş H; Reisoğlu A; Zincircioğlu G; Eryanilmaz G
    Acta Orthop Traumatol Turc; 2002; 36(5):384-9. PubMed ID: 12594343
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effectiveness of sonography assisted minimal invasive plate osteosynthesis (MIPO) compare with fluoroscope assisted in femoral shaft fracture: A cadaveric study.
    Saengsin J; Vaseenon T; Pattamapaspong N; Kritsaneephaiboon A
    Injury; 2017 Aug; 48(8):1758-1763. PubMed ID: 28689808
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Immediate weight-bearing after treatment of a comminuted fracture of the femoral shaft with a statically locked intramedullary nail.
    Brumback RJ; Toal TR; Murphy-Zane MS; Novak VP; Belkoff SM
    J Bone Joint Surg Am; 1999 Nov; 81(11):1538-44. PubMed ID: 10565645
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison between intramedullary nailing and minimally invasive plate osteosynthesis for tibial shaft fractures.
    Kang H; Rho JY; Song JK; Choi J; Kwon YS; Choi S
    Injury; 2021 Apr; 52(4):1011-1016. PubMed ID: 33563414
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Percutaneous cerclage wiring and minimally invasive plate osteosynthesis (MIPO): a percutaneous reduction technique in the treatment of Vancouver type B1 periprosthetic femoral shaft fractures.
    Apivatthakakul T; Phornphutkul C; Bunmaprasert T; Sananpanich K; Fernandez Dell'Oca A
    Arch Orthop Trauma Surg; 2012 Jun; 132(6):813-22. PubMed ID: 22389063
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Clinical results of using minimally invasive long plate osteosynthesis versus conventional approach for extensive comminuted metadiaphyseal fractures of the radius.
    Chen CY; Lin KC; Yang SW; Renn JH; Tarng YW
    Arch Orthop Trauma Surg; 2015 Mar; 135(3):361-7. PubMed ID: 25663020
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Narrow locking compression plate vs long philos plate for minimally invasive plate osteosynthesis of spiral humerus shaft fractures.
    Jeong JJ; Park SE; Lee HH; Ji JH; Park MS; Park YT
    BMC Musculoskelet Disord; 2019 Aug; 20(1):381. PubMed ID: 31421675
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A prospective randomized study of operative treatment for noncomminuted humeral shaft fractures: conventional open plating versus minimal invasive plate osteosynthesis.
    Kim JW; Oh CW; Byun YS; Kim JJ; Park KC
    J Orthop Trauma; 2015 Apr; 29(4):189-94. PubMed ID: 25210833
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Minimally Invasive Plate Osteosynthesis (MIPO) technique for complex tibial shaft fracture.
    Choi S; Lee TJ; Kim S; Cho C; Shim S; Kang H
    Acta Orthop Belg; 2019 Jun; 85(2):224-233. PubMed ID: 31315014
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Surgical treatment of humeral diaphyseal fractures].
    Smejkal K; Lochman P; Dědek T; Trlica J
    Acta Chir Orthop Traumatol Cech; 2014; 81(2):129-34. PubMed ID: 25105787
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Minimally invasive plate osteosynthesis using a locking compression plate for distal femoral fractures.
    Nayak RM; Koichade MR; Umre AN; Ingle MV
    J Orthop Surg (Hong Kong); 2011 Aug; 19(2):185-90. PubMed ID: 21857042
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Minimally-invasive plate osteosynthesis in distal tibial fractures: Results and complications.
    Vidović D; Matejčić A; Ivica M; Jurišić D; Elabjer E; Bakota B
    Injury; 2015 Nov; 46 Suppl 6():S96-9. PubMed ID: 26584733
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Outcomes of distal femoral fractures treated with minimally invasive plate osteosynthesis versus open reduction internal fixation with combined locking plate and interfragmentary screws.
    Wang SH; Wu CC; Li WT; Shen HC; Lin LC; Pan RY
    Int J Surg; 2019 May; 65():107-112. PubMed ID: 30951872
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Osteosynthesis for periprosthetic supracondylar fracture above a total knee arthroplasty using a locking compression plate].
    Krbec M; Motycka J; Lunácek L; Dousa P
    Acta Chir Orthop Traumatol Cech; 2009 Dec; 76(6):473-8. PubMed ID: 20067694
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.