These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
360 related articles for article (PubMed ID: 34233702)
1. Bone plate fixation ability on the dorsal and lateral sides of a metacarpal shaft transverse fracture. Chiu YC; Hsu CE; Ho TY; Ting YN; Tsai MT; Hsu JT J Orthop Surg Res; 2021 Jul; 16(1):441. PubMed ID: 34233702 [TBL] [Abstract][Full Text] [Related]
2. New fixation approach for transverse metacarpal neck fracture: a biomechanical study. Chiu YC; Tsai MT; Hsu CE; Hsu HC; Huang HL; Hsu JT J Orthop Surg Res; 2018 Jul; 13(1):183. PubMed ID: 30045774 [TBL] [Abstract][Full Text] [Related]
3. Effect of oblique headless compression screw fixation for metacarpal shaft fracture: a biomechanical in vitro study. Chiu YC; Ho TY; Ting YN; Tsai MT; Huang HL; Hsu CE; Hsu JT BMC Musculoskelet Disord; 2021 Feb; 22(1):146. PubMed ID: 33546670 [TBL] [Abstract][Full Text] [Related]
4. Comparison of the fixation ability between lag screw and bone plate for oblique metacarpal shaft fracture. Chiu YC; Ho TY; Hsu CE; Ting YN; Tsai MT; Hsu JT J Orthop Surg Res; 2022 Feb; 17(1):72. PubMed ID: 35123532 [TBL] [Abstract][Full Text] [Related]
5. Biomechanical analysis of plate versus K-wire fixation for metacarpal shaft fractures with wedge-shaped bone defects. Chiu YC; Ho TY; Hsu CE; Yeh CW; Ting YN; Tsai MT; Hsu JT BMC Musculoskelet Disord; 2024 May; 25(1):350. PubMed ID: 38702748 [TBL] [Abstract][Full Text] [Related]
6. Comparing biomechanical strength of unicortical locking plate versus bicortical compression plate for transverse midshaft metacarpal fracture. Shanmugam R; Jian CYCCS; Haseeb A; Aik S J Orthop Surg (Hong Kong); 2018; 26(3):2309499018802511. PubMed ID: 30270746 [TBL] [Abstract][Full Text] [Related]
7. Biomechanical study on fixation methods for horizontal oblique metacarpal shaft fractures. Chiu YC; Hsu CE; Ho TY; Ting YN; Tsai MT; Hsu JT J Orthop Surg Res; 2022 Aug; 17(1):374. PubMed ID: 35922799 [TBL] [Abstract][Full Text] [Related]
8. Effect of a figure-of-eight cerclage wire with two Kirschner wires on fixation strength for transverse metacarpal shaft fractures: an in vitro study with artificial bone. Chiu YC; Hsu CE; Ho TY; Ting YN; Tsai MT; Hsu JT BMC Musculoskelet Disord; 2021 May; 22(1):431. PubMed ID: 33971840 [TBL] [Abstract][Full Text] [Related]
9. Headless Screw Fixation of Metacarpal Neck Fractures: A Mechanical Comparative Analysis. Jones CM; Padegimas EM; Weikert N; Greulich S; Ilyas AM; Siegler S Hand (N Y); 2019 Mar; 14(2):187-192. PubMed ID: 28933187 [TBL] [Abstract][Full Text] [Related]
10. Comparison between locking and non-locking plates for fixation of metacarpal fractures in an animal model. Ochman S; Doht S; Paletta J; Langer M; Raschke MJ; Meffert RH J Hand Surg Am; 2010 Apr; 35(4):597-603. PubMed ID: 20299161 [TBL] [Abstract][Full Text] [Related]
11. Comparison of Dorsal Plate Fixation Versus Intramedullary Headless Screw Fixation of Unstable Metacarpal Shaft Fractures: A Biomechanical Study. Melamed E; Hinds RM; Gottschalk MB; Kennedy OD; Capo JT Hand (N Y); 2016 Dec; 11(4):421-426. PubMed ID: 28149208 [No Abstract] [Full Text] [Related]
12. Comparison of the fixation ability of headless compression screws and locking plate for metacarpal shaft transverse fracture. Chiu YC; Hsu CE; Ho TY; Ting YN; Wei BH; Tsai MT; Hsu JT Medicine (Baltimore); 2021 Oct; 100(39):e27375. PubMed ID: 34596154 [TBL] [Abstract][Full Text] [Related]
13. Unicortical PEEK inset locking fixation for metacarpal fractures: a biomechanical study. Mudrick CA; Owen JR; Wayne JS; Isaacs JE Eur J Orthop Surg Traumatol; 2014 Dec; 24(8):1415-20. PubMed ID: 24121825 [TBL] [Abstract][Full Text] [Related]
14. Biomechanical study of the fixation ability of the dorsal and volar locking plate for transverse metacarpal neck fractures. Ho TY; Hsu CE; Wang WC; Ting YN; Tsai MT; Chiu YC; Hsu JT Medicine (Baltimore); 2023 Sep; 102(36):e34981. PubMed ID: 37682204 [TBL] [Abstract][Full Text] [Related]
15. A Comparison of Locking Plates and Intramedullary Pinning for Fixation of Metacarpal Shaft Fractures. Dreyfuss D; Allon R; Izacson N; Hutt D Hand (N Y); 2019 Jan; 14(1):27-33. PubMed ID: 30192648 [TBL] [Abstract][Full Text] [Related]
16. A biomechanical analysis of plate fixation using unicortical and bicortical screws in transverse metacarpal fracture models subjected to 4-point bending and dynamical bending test. Liodaki E; Wendlandt R; Waizner K; Schopp BE; Mailänder P; Stang F Medicine (Baltimore); 2017 Jul; 96(27):e6926. PubMed ID: 28682860 [TBL] [Abstract][Full Text] [Related]
17. Biomechanical analysis of locking plates for fixation of metacarpal shaft fractures: A finite element analysis. Zhang JF; Li Y; Huo YX; Yan M; Liang SL; Wang L; Wang BC Orthop Traumatol Surg Res; 2022 Dec; 108(8):103340. PubMed ID: 35643362 [TBL] [Abstract][Full Text] [Related]
18. Fixation of Metacarpal Shaft Fractures: Biomechanical Comparison of Intramedullary Nail Crossed K-Wires and Plate-Screw Constructs. Curtis BD; Fajolu O; Ruff ME; Litsky AS Orthop Surg; 2015 Aug; 7(3):256-60. PubMed ID: 26311101 [TBL] [Abstract][Full Text] [Related]
19. A Comparative Study of Tensile Strength of Three Operative Fixation Techniques for Metacarpal Shaft Fractures in Adults: A Cadaver Study. Oh JR; Kim DS; Yeom JS; Kang SK; Kim YT Clin Orthop Surg; 2019 Mar; 11(1):120-125. PubMed ID: 30838116 [TBL] [Abstract][Full Text] [Related]
20. Biomechanical comparison of double-row locking plates versus single- and double-row non-locking plates in a comminuted metacarpal fracture model. Gajendran VK; Szabo RM; Myo GK; Curtiss SB J Hand Surg Am; 2009 Dec; 34(10):1851-8. PubMed ID: 19897325 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]