These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

132 related articles for article (PubMed ID: 34239231)

  • 21. The utility of the microvascular anastomotic coupler in free tissue transfer.
    Grewal AS; Erovic B; Strumas N; Enepekides DJ; Higgins KM
    Can J Plast Surg; 2012; 20(2):98-102. PubMed ID: 23730156
    [TBL] [Abstract][Full Text] [Related]  

  • 22. The Use of Venous Coupler Device in Free Tissue Transfers for Oral and Maxillofacial Reconstruction.
    Li R; Zhang R; He W; Qiao Y; Li W
    J Oral Maxillofac Surg; 2015 Nov; 73(11):2225-31. PubMed ID: 26126918
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Utilization of microvascular couplers in salvage arterial anastomosis in head and neck free flap surgery: Case series and literature review.
    Li MM; Tamaki A; Seim NB; Kang SY; Ozer E; Agrawal A; Old MO
    Head Neck; 2020 Aug; 42(8):E1-E7. PubMed ID: 32196817
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Double Thread Suspension: A Novel Technique to Facilitate End-to-Side Venous Anastomosis With a Microvascular Coupling Device in Head and Neck Reconstruction.
    Zhang S; Xiong T; Li S; Liu X; Yang Y; Zhao Z
    J Oral Maxillofac Surg; 2021 Sep; 79(9):1954-1962. PubMed ID: 33901452
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Venous Coupler in Pediatric Free Tissue Transfer: Case Series and Literature Review.
    Aldekhayel S; Alshomer F; Alhazmi B
    Plast Reconstr Surg Glob Open; 2020 Feb; 8(2):e2647. PubMed ID: 32309092
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Safety of Coupled Arterial Anastomosis in Autologous Breast Reconstruction.
    McLaughlin M; Porter BE; Cohen-Shohet R; Leyngold MM
    J Reconstr Microsurg; 2021 Feb; 37(2):132-135. PubMed ID: 32820472
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Comparison of venous couplers versus hand-sewn technique in free flap breast reconstruction.
    Dimitropoulos G; Efanov JI; Paek L; Bou-Merhi J; Danino MA
    Ann Chir Plast Esthet; 2019 Apr; 64(2):150-156. PubMed ID: 30846201
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Smaller Diameter Anastomotic Coupling Devices Have Higher Rates of Venous Thrombosis in Microvascular Free Tissue Transfer.
    Hanson SE; Mitchell MB; Palivela N; Peng SA; Feng L; Largo RD; Butler CE; Garvey PB
    Plast Reconstr Surg; 2017 Dec; 140(6):1293-1300. PubMed ID: 28820839
    [TBL] [Abstract][Full Text] [Related]  

  • 29. 1000 consecutive venous anastomoses using the microvascular anastomotic coupler in breast reconstruction.
    Jandali S; Wu LC; Vega SJ; Kovach SJ; Serletti JM
    Plast Reconstr Surg; 2010 Mar; 125(3):792-8. PubMed ID: 20195107
    [TBL] [Abstract][Full Text] [Related]  

  • 30. The microvascular anastomotic coupler for venous anastomoses in free flap breast reconstruction improves outcomes.
    Fitzgerald O'Connor E; Rozen WM; Chowdhry M; Patel NG; Chow WT; Griffiths M; Ramakrishnan VV
    Gland Surg; 2016 Apr; 5(2):88-92. PubMed ID: 27047776
    [TBL] [Abstract][Full Text] [Related]  

  • 31. A comparison of microsurgical venous anastomosis techniques.
    Umezawa H; Ogawa R; Nakamizo M; Yokoshima K; Hyakusoku H
    J Nippon Med Sch; 2015; 82(1):14-20. PubMed ID: 25797870
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Venous Thrombosis in Handsewn versus Coupled Venous Anastomoses in 857 Consecutive Breast Free Flaps.
    Kulkarni AR; Mehrara BJ; Pusic AL; Cordeiro PG; Matros E; McCarthy CM; Disa JJ
    J Reconstr Microsurg; 2016 Mar; 32(3):178-82. PubMed ID: 26372685
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Microvascular anastomotic arterial coupling: A systematic review.
    Pafitanis G; Nicolaides M; O'Connor EF; Raveendran M; Ermogenous P; Psaras G; Rose V; Myers S
    J Plast Reconstr Aesthet Surg; 2021 Jun; 74(6):1286-1302. PubMed ID: 33551362
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Clinical experience with the 3M microvascular coupling anastomotic device in 100 free-tissue transfers.
    Ahn CY; Shaw WW; Berns S; Markowitz BL
    Plast Reconstr Surg; 1994 Jun; 93(7):1481-4. PubMed ID: 8208815
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Unique Complications of Venous Anastomotic Couplers: A Systematic Review of the Literature.
    Wu GJ; Loewenstein SN; Mailey BA; Sasor S; Cook J; Hassanein AH
    J Reconstr Microsurg; 2020 Jul; 36(6):403-411. PubMed ID: 32106314
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [The application of microvascular anastomotic device for free flap transfer in reconstruction of oral and maxillofacial defects].
    Sun Q; Zhao JF; Fang Z; Wang HB; Sun ML
    Shanghai Kou Qiang Yi Xue; 2016 Apr; 25(2):195-8. PubMed ID: 27329884
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Meta-analysis of arterial anastomosis techniques in head and neck free tissue transfer.
    Wang YJ; Wang XL; Jin S; Zhang R; Gao YQ
    PLoS One; 2021; 16(4):e0249418. PubMed ID: 33793654
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Influence of coupler size on revision rate and timing of revision after free flap tissue transfer in the head and neck.
    Kisser U; Adderson-Kisser C; Baumeister P; Reiter M
    Eur Arch Otorhinolaryngol; 2018 Jan; 275(1):199-206. PubMed ID: 29127507
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Compression Anastomosis Clips Versus a Hand-Sewn Technique for Intestinal Anastomosis in Pigs.
    Kuśnierz K; Kajor M; Zaworonkow D; Lekston Z; Ciupińska-Kajor M; Seweryn M; Lampe P
    Adv Clin Exp Med; 2015; 24(6):1019-29. PubMed ID: 26771975
    [TBL] [Abstract][Full Text] [Related]  

  • 40.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.