These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

123 related articles for article (PubMed ID: 34243284)

  • 1. Development of a filtered AXUV diode array for X-pinch soft x-ray spectra in the energy range of 1-10 keV.
    Ham S; Ryu J; Park S; Chung KJ; Ghim YC; Woo HJ; Hwang YS
    Rev Sci Instrum; 2021 May; 92(5):053509. PubMed ID: 34243284
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Diagnosing x-ray power and energy of tungsten wire array z-pinch with a flat spectral response x-ray diode.
    Wang KL; Ren XD; Huang XB; Zhang SQ; Zhou ST; Dan JK; Li J; Xu Q; Ouyang K; Cai HC; Wei B; Ji C; Feng SP; Wang M; Xie WP; Deng JJ
    Rev Sci Instrum; 2015 Nov; 86(11):113508. PubMed ID: 26628136
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Recover soft x-ray spectrum using virtual flat response channels with filtered x-ray diode array.
    Tianming S; Jiamin Y; Rongqing Y
    Rev Sci Instrum; 2012 Nov; 83(11):113102. PubMed ID: 23206046
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Application of AXUV diode detectors at ASDEX Upgrade.
    Bernert M; Eich T; Burckhart A; Fuchs JC; Giannone L; Kallenbach A; McDermott RM; Sieglin B;
    Rev Sci Instrum; 2014 Mar; 85(3):033503. PubMed ID: 24689581
    [TBL] [Abstract][Full Text] [Related]  

  • 5. RADCAM-A radiation camera system combining foil bolometers, AXUV diodes, and filtered soft x-ray diodes.
    Sheikh UA; Simons L; Duval BP; Février O; Moret D; Allegrucci A; Bernert M; Crisinel F; Tersztyánszky T; Villinger O
    Rev Sci Instrum; 2022 Nov; 93(11):113513. PubMed ID: 36461455
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Soft x-ray array system with variable filters for the DIII-D tokamak.
    Hollmann EM; Chousal L; Fisher RK; Hernandez R; Jackson GL; Lanctot MJ; Pidcoe SV; Shankara J; Taussig DA
    Rev Sci Instrum; 2011 Nov; 82(11):113507. PubMed ID: 22128975
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Absolute radiant power measurement for the Au M lines of laser-plasma using a calibrated broadband soft X-ray spectrometer with flat-spectral response.
    Troussel P; Villette B; Emprin B; Oudot G; Tassin V; Bridou F; Delmotte F; Krumrey M
    Rev Sci Instrum; 2014 Jan; 85(1):013503. PubMed ID: 24517761
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Grazing incidence extreme ultraviolet spectrometer fielded with time resolution in a hostile z-pinch environment.
    Williamson KM; Kantsyrev VL; Safronova AS; Wilcox PG; Cline W; Batie S; LeGalloudec B; Nalajala V; Astanovitsky A
    Rev Sci Instrum; 2011 Sep; 82(9):093506. PubMed ID: 21974586
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Compact hard x-ray flash radiography device based on wire-shorted low-impedance rod pinch diode.
    Wang T; Shi H; Zhang P; Wang Y; Wang D; Xu M; Li X; Wu J; Qiu A
    Rev Sci Instrum; 2024 Jul; 95(7):. PubMed ID: 38984881
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Use of a priori spectral information in the measurement of x-ray flux with filtered diode arrays.
    Marrs RE; Widmann K; Brown GV; Heeter RF; MacLaren SA; May MJ; Moore AS; Schneider MB
    Rev Sci Instrum; 2015 Oct; 86(10):103511. PubMed ID: 26520959
    [TBL] [Abstract][Full Text] [Related]  

  • 11. X-ray emission from z pinches at 10 7 A: current scaling, gap closure, and shot-to-shot fluctuations.
    Stygar WA; Ives HC; Fehl DL; Cuneo ME; Mazarakis MG; Bailey JE; Bennett GR; Bliss DE; Chandler GA; Leeper RJ; Matzen MK; McDaniel DH; McGurn JS; McKenney JL; Mix LP; Muron DJ; Porter JL; Ramirez JJ; Ruggles LE; Seamen JF; Simpson WW; Speas CS; Spielman RB; Struve KW; Torres JA; Vesey RA; Wagoner TC; Gilliland TL; Horry ML; Jobe DO; Lazier SE; Mills JA; Mulville TD; Pyle JH; Romero TM; Seamen JJ; Smelser RM
    Phys Rev E Stat Nonlin Soft Matter Phys; 2004 Apr; 69(4 Pt 2):046403. PubMed ID: 15169102
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Time-dependent soft and hard x-ray measurements using streak and x-ray diode array diagnostic systems.
    Shpilman Z; Silberstein S; Rubin D; Ehrlich Y; Oysher Z; Ferber Y; Levy I
    Rev Sci Instrum; 2021 Mar; 92(3):033527. PubMed ID: 33819984
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Characteristics and scaling of tungsten-wire-array z -pinch implosion dynamics at 20 MA.
    Cuneo ME; Waisman EM; Lebedev SV; Chittenden JP; Stygar WA; Chandler GA; Vesey RA; Yu EP; Nash TJ; Bliss DE; Sarkisov GS; Wagoner TC; Bennett GR; Sinars DB; Porter JL; Simpson WW; Ruggles LE; Wenger DF; Garasi CJ; Oliver BV; Aragon RA; Fowler WE; Hettrick MC; Idzorek GC; Johnson D; Keller K; Lazier SE; McGurn JS; Mehlhorn TA; Moore T; Nielsen DS; Pyle J; Speas S; Struve KW; Torres JA
    Phys Rev E Stat Nonlin Soft Matter Phys; 2005 Apr; 71(4 Pt 2):046406. PubMed ID: 15903793
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Photon counting x-ray imaging with K-edge filtered x-rays: A simulation study.
    Atak H; Shikhaliev PM
    Med Phys; 2016 Mar; 43(3):1385-400. PubMed ID: 26936723
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Investigation of spectra unfolded for a filtered x-ray diode array with improved smoothness.
    Li J; Huang XB; Zhang SQ; Yang LB; Xie WP; Pu YK
    Rev Sci Instrum; 2009 Jun; 80(6):063106. PubMed ID: 19566195
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Coarse spectral characterization of warm x-rays at the Z facility using a filtered thermoluminescent dosimeter array.
    Harper-Slaboszewicz VJ; Ulmen BA; Parzyck CT; Ampleford DJ; McCourt AL; Bell KS; Coverdale CA
    Rev Sci Instrum; 2017 Apr; 88(4):043501. PubMed ID: 28456222
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Electron Temperature Measurements Using a Two-Filter Soft X-ray Array in VEST.
    Lee MW; Lim S; Jeong W; Kim S; Kim JH; Hwang YS; Sung C
    Sensors (Basel); 2023 Oct; 23(20):. PubMed ID: 37896452
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Characteristics of a molybdenum X-pinch X-ray source as a probe source for X-ray diffraction studies.
    Zucchini F; Bland SN; Chauvin C; Combes P; Sol D; Loyen A; Roques B; Grunenwald J
    Rev Sci Instrum; 2015 Mar; 86(3):033507. PubMed ID: 25832229
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Axial x-ray backlighting of wire-array Z-pinches using X pinches.
    Blesener IC; Greenly JB; Pikuz SA; Shelkovenko TA; Vishniakou S; Hammer DA; Kusse BR
    Rev Sci Instrum; 2009 Dec; 80(12):123505. PubMed ID: 20059143
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Soft x-ray spectrum unfold of K-edge filtered x-ray diode arrays using cubic splines.
    Barnak DH; Davies JR; Knauer JP; Kozlowski PM
    Rev Sci Instrum; 2020 Jul; 91(7):073102. PubMed ID: 32752842
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.