  • 21. Magnetic field and temperature dual-parameter sensor based on magnetic fluid materials filled photonic crystal fiber.
    Wang J; Pei L; Wang J; Ruan Z; Zheng J; Li J; Ning T
    Opt Express; 2020 Jan; 28(2):1456-1471. PubMed ID: 32121856
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Reflective all-fiber magnetic field sensor based on microfiber and magnetic fluid.
    Luo L; Pu S; Tang J; Zeng X; Lahoubi M
    Opt Express; 2015 Jul; 23(14):18133-42. PubMed ID: 26191872
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Low-temperature cross-talk magnetic-field sensor based on tapered all-solid waveguide-array fiber and magnetic fluids.
    Miao Y; Ma X; Wu J; Song B; Zhang H; Zhang K; Liu B; Yao J
    Opt Lett; 2015 Aug; 40(16):3905-8. PubMed ID: 26274690
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Highly sensitive Mach-Zehnder interferometric micromagnetic field sensor based on 3D printing technology.
    Zhang D; Zhang Z; Wei H; Krishnaswamy S
    Appl Opt; 2021 Sep; 60(27):8493-8498. PubMed ID: 34612952
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A Mach-Zehnder Fabry-Perot hybrid fiber-optic interferometer operating at the thermal noise limit.
    Hoque NMR; Duan L
    Sci Rep; 2022 Jul; 12(1):12130. PubMed ID: 35840651
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Fiber Mach-Zehnder-interferometer-based liquid crystal biosensor for detecting enzymatic reactions of penicillinase.
    Hu J; Fu D; Xia C; Long S; Lu C; Sun W; Liu Y
    Appl Opt; 2019 Jun; 58(17):4806-4811. PubMed ID: 31251304
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Prospects of Photonic Crystal Fiber as Physical Sensor: An Overview.
    De M; Gangopadhyay TK; Singh VK
    Sensors (Basel); 2019 Jan; 19(3):. PubMed ID: 30678109
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Liquid crystal infiltrated photonic crystal fibers for electric field intensity measurements.
    Mathews S; Farrell G; Semenova Y
    Appl Opt; 2011 Jun; 50(17):2628-35. PubMed ID: 21673765
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Highly sensitive fiber loop ringdown strain sensor using photonic crystal fiber interferometer.
    Zhou W; Wong WC; Chan CC; Shao LY; Dong X
    Appl Opt; 2011 Jul; 50(19):3087-92. PubMed ID: 21743506
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Fiber in-line Mach-Zehnder interferometer based on near-elliptical core photonic crystal fiber for temperature and strain sensing.
    Liang H; Zhang W; Wang H; Geng P; Zhang S; Gao S; Yang C; Li J
    Opt Lett; 2013 Oct; 38(20):4019-22. PubMed ID: 24321910
    [TBL] [Abstract][Full Text] [Related]  

  • 31. A reflective photonic crystal fiber temperature sensor probe based on infiltration with liquid mixtures.
    Wang R; Yao J; Miao Y; Lu Y; Xu D; Luan N; Musideke M; Duan L; Hao C
    Sensors (Basel); 2013 Jun; 13(6):7916-25. PubMed ID: 23787726
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Refractive index measurement using photonic crystal fiber-based Fabry-Perot interferometer.
    Deng M; Tang CP; Zhu T; Rao YJ; Xu LC; Han M
    Appl Opt; 2010 Mar; 49(9):1593-8. PubMed ID: 20300155
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Miniature tapered photonic crystal fiber interferometer with enhanced sensitivity by acid microdroplets etching.
    Qiu SJ; Chen Y; Kou JL; Xu F; Lu YQ
    Appl Opt; 2011 Aug; 50(22):4328-32. PubMed ID: 21833106
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Design Rule of Mach-Zehnder Interferometer Sensors for Ultra-High Sensitivity.
    Xie Y; Zhang M; Dai D
    Sensors (Basel); 2020 May; 20(9):. PubMed ID: 32380779
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Ultra-high sensitivity Fabry-Perot interferometer gas refractive index fiber sensor based on photonic crystal fiber and Vernier effect.
    Quan M; Tian J; Yao Y
    Opt Lett; 2015 Nov; 40(21):4891-4. PubMed ID: 26512476
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Graphene-deposited photonic crystal fibers for continuous refractive index sensing applications.
    Tan YC; Tou ZQ; Chow KK; Chan CC
    Opt Express; 2015 Nov; 23(24):31286-94. PubMed ID: 26698755
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Magnetic Field Sensing Using Tapered Small-Core Optical Fibre Surrounded by Different Concentrations of Magnetic Fluid.
    Kumar R
    Sensors (Basel); 2022 Nov; 22(21):. PubMed ID: 36366233
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Ambient refractive index-independent bending vector sensor based on seven-core photonic crystal fiber using lateral offset splicing.
    Ou Z; Yu Y; Yan P; Wang J; Huang Q; Chen X; Du C; Wei H
    Opt Express; 2013 Oct; 21(20):23812-21. PubMed ID: 24104292
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Photonic crystal fiber modal interferometer with Pd/WO
    Zhang YN; Wu Q; Peng H; Zhao Y
    Rev Sci Instrum; 2016 Dec; 87(12):125002. PubMed ID: 28040930
    [TBL] [Abstract][Full Text] [Related]  

  • 40. High-sensitivity gas pressure sensor based on hollow-core photonic bandgap fiber Mach-Zehnder interferometer.
    Mao C; Huang B; Wang Y; Huang Y; Zhang L; Shao Y; Wang Y
    Opt Express; 2018 Nov; 26(23):30108-30115. PubMed ID: 30469890
    [TBL] [Abstract][Full Text] [Related]  