These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

155 related articles for article (PubMed ID: 34263987)

  • 1. Use of cleaved wedge geometry for plan-view transmission electron microscopy sample preparation.
    Palisaitis J
    Microsc Res Tech; 2021 Dec; 84(12):3182-3190. PubMed ID: 34263987
    [TBL] [Abstract][Full Text] [Related]  

  • 2. An improved FIB sample preparation technique for site-specific plan-view specimens: A new cutting geometry.
    Li C; Habler G; Baldwin LC; Abart R
    Ultramicroscopy; 2018 Jan; 184(Pt A):310-317. PubMed ID: 29096249
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Applications of the FIB lift-out technique for TEM specimen preparation.
    Giannuzzi LA; Drown JL; Brown SR; Irwin RB; Stevie FA
    Microsc Res Tech; 1998 May; 41(4):285-90. PubMed ID: 9633946
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A user-friendly FIB lift-out technique to prepare plan-view TEM sample of 2D thin film materials.
    Rajput NS; Sloyan K; Anjum DH; Chiesa M; Ghaferi AA
    Ultramicroscopy; 2022 May; 235():113496. PubMed ID: 35245872
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Advanced preparation of plan-view specimens on a MEMS chip for
    Minenkov A; Šantić N; Truglas T; Aberl J; Vukušić L; Brehm M; Groiss H
    MRS Bull; 2022; 47(4):359-370. PubMed ID: 35968543
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Plan-view transmission electron microscopy specimen preparation for atomic layer materials using a focused ion beam approach.
    Lee LH; Yu CH; Wei CY; Lee PC; Huang JS; Wen CY
    Ultramicroscopy; 2019 Feb; 197():95-99. PubMed ID: 30537672
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A new method for preparing plan-view TEM specimen of multilayered films using focused ion beam.
    Kato T; Muroga T; Iijima Y; Saitoh T; Yamada Y; Izumi T; Shiohara Y; Hirayama T; Ikuhara Y
    J Electron Microsc (Tokyo); 2004; 53(5):501-4. PubMed ID: 15582955
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A site-specific focused-ion-beam lift-out method for cryo Transmission Electron Microscopy.
    Rubino S; Akhtar S; Melin P; Searle A; Spellward P; Leifer K
    J Struct Biol; 2012 Dec; 180(3):572-6. PubMed ID: 23000702
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A method for directly correlating site-specific cross-sectional and plan-view transmission electron microscopy of individual nanostructures.
    Schreiber DK; Adusumilli P; Hemesath ER; Seidman DN; Petford-Long AK; Lauhon LJ
    Microsc Microanal; 2012 Dec; 18(6):1410-8. PubMed ID: 23146147
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Novel Method for Preparing Transmission Electron Microscopy Samples of Micrometer-Sized Powder Particles by Using Focused Ion Beam.
    Kim TH; Kang MC; Jung GB; Kim DS; Yang CW
    Microsc Microanal; 2017 Oct; 23(5):1055-1060. PubMed ID: 28899437
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An optimized sample preparation approach for atomic resolution in situ studies of thin films.
    Moatti A; Sachan R; Prater J; Narayan J
    Microsc Res Tech; 2018 Nov; 81(11):1250-1256. PubMed ID: 30368970
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Improvements in performance of focused ion beam cross-sectioning: aspects of ion-sample interaction.
    Ishitani T; Umemura K; Ohnishi T; Yaguchi T; Kamino T
    J Electron Microsc (Tokyo); 2004; 53(5):443-9. PubMed ID: 15582945
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A review of focused ion beam technology and its applications in transmission electron microscopy.
    Sugiyama M; Sigesato G
    J Electron Microsc (Tokyo); 2004; 53(5):527-36. PubMed ID: 15582961
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Sample preparation by focused ion beam micromachining for transmission electron microscopy imaging in front-view.
    Jublot M; Texier M
    Micron; 2014 Jan; 56():63-7. PubMed ID: 24200984
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Application of FIB with micro pick-up to microstructural study of irradiated SiC/SiC composites.
    Ozawa K; Kondo S; Kishimoto H; Kohyama A
    J Electron Microsc (Tokyo); 2004; 53(5):519-21. PubMed ID: 15582959
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A flexible method for the preparation of thin film samples for in situ TEM characterization combining shadow-FIB milling and electron-beam-assisted etching.
    Liebig JP; Göken M; Richter G; Mačković M; Przybilla T; Spiecker E; Pierron ON; Merle B
    Ultramicroscopy; 2016 Dec; 171():82-88. PubMed ID: 27643461
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Atomic layer deposited Al
    Gurrentz JM; Jarvis KA; Gearba-Dolocan IR; Rose MJ
    Ultramicroscopy; 2022 Sep; 239():113562. PubMed ID: 35675735
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The focused ion beam fold-out: sample preparation method for transmission electron microscopy.
    Floresca HC; Jeon J; Wang JG; Kim MJ
    Microsc Microanal; 2009 Dec; 15(6):558-63. PubMed ID: 19804654
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A reliable approach to prepare brittle semiconducting materials for cross-sectional transmission electron microscopy.
    Dycus JH; Lebeau JM
    J Microsc; 2017 Dec; 268(3):225-229. PubMed ID: 28686283
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Plan-view preparation of TEM specimens from thin films using adhesive tape.
    Czigány Z
    Microsc Microanal; 2011 Dec; 17(6):886-8. PubMed ID: 22000156
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.