120 related articles for article (PubMed ID: 34266014)
1. High-accuracy room temperature planar absolute radiometer based on vertically aligned carbon nanotubes.
Vaskuri AK; Stephens MS; Tomlin NA; Spidell MT; Yung CS; Walowitz AJ; Straatsma C; Harber D; Lehman JH
Opt Express; 2021 Jul; 29(14):22533-22552. PubMed ID: 34266014
[TBL] [Abstract][Full Text] [Related]
2. Room temperature laser power standard using a microfabricated, electrical substitution bolometer.
Stephens M; Yung CS; Tomlin NA; Vaskuri A; Ryger I; Spidell M; White MG; Jenkins T; Landry J; Sereke T; Lehman JH
Rev Sci Instrum; 2021 Feb; 92(2):025107. PubMed ID: 33648050
[TBL] [Abstract][Full Text] [Related]
3. Room-temperature calorimeter for x-ray free-electron lasers.
Tanaka T; Kato M; Saito N; Tono K; Yabashi M; Ishikawa T
Rev Sci Instrum; 2015 Sep; 86(9):093104. PubMed ID: 26429426
[TBL] [Abstract][Full Text] [Related]
4. Intramural Comparison of NIST Laser and Optical Fiber Power Calibrations.
Lehman JH; Vayshenker I; Livigni DJ; Hadler J
J Res Natl Inst Stand Technol; 2004; 109(2):291-8. PubMed ID: 27366611
[TBL] [Abstract][Full Text] [Related]
5. Intercomparison of the LBIR Absolute Cryogenic Radiometers to the NIST Optical Power Measurement Standard.
Fedchak JA; Carter AC; Datla R
J Res Natl Inst Stand Technol; 2006; 111(4):325-34. PubMed ID: 27274936
[TBL] [Abstract][Full Text] [Related]
6. Developments for a New Spectral Irradiance Scale at the National Institute of Standards and Technology.
Tsai BK
J Res Natl Inst Stand Technol; 1997; 102(5):551-558. PubMed ID: 27805142
[TBL] [Abstract][Full Text] [Related]
7. Calibration of a pyroelectric detector at 10.6 microm with the National Institute of Standards and Technology high-accuracy cryogenic radiometer.
Gentile TR; Houston JM; Eppeldauer G; Migdall AL; Cromer CL
Appl Opt; 1997 Jun; 36(16):3614-21. PubMed ID: 18253383
[TBL] [Abstract][Full Text] [Related]
8. Characterization of an absolute cryogenic radiometer as a standard detector for radiant-power measurements.
Datla RU; Stock K; Parr AC; Hoyt CC; Miller PJ; Foukal PV
Appl Opt; 1992 Dec; 31(34):7219-25. PubMed ID: 20802586
[TBL] [Abstract][Full Text] [Related]
9. Planar hyperblack absolute radiometer.
Lehman J; Steiger A; Tomlin N; White M; Kehrt M; Ryger I; Stephens M; Monte C; Mueller I; Hollandt J; Dowell M
Opt Express; 2016 Nov; 24(23):25911-25921. PubMed ID: 27857330
[TBL] [Abstract][Full Text] [Related]
10. Realization of a scale of absolute spectral response using the National Institute of Standards and Technology high-accuracy cryogenic radiometer.
Gentile TR; Houston JM; Cromer CL
Appl Opt; 1996 Aug; 35(22):4392-403. PubMed ID: 21102852
[TBL] [Abstract][Full Text] [Related]
11. The NIST High Accuracy Scale for Absolute Spectral Response from 406 nm to 920 nm.
Larason TC; Bruce SS; Cromer CL
J Res Natl Inst Stand Technol; 1996; 101(2):133-140. PubMed ID: 27805120
[TBL] [Abstract][Full Text] [Related]
12. Absolute measurement of F2-laser power at 157 nm.
Kück S; Brandt F; Kremling HA; Gottwald A; Hoehl A; Richter M
Appl Opt; 2006 May; 45(14):3325-30. PubMed ID: 16676038
[TBL] [Abstract][Full Text] [Related]
13. Realization of the National Institute of Standards and Technology detector-based spectral irradiance scale.
Yoon HW; Gibson CE; Barnes PY
Appl Opt; 2002 Oct; 41(28):5879-90. PubMed ID: 12371545
[TBL] [Abstract][Full Text] [Related]
14. The Candela and Photometric and Radiometric Measurements.
Parr AC
J Res Natl Inst Stand Technol; 2001; 106(1):151-86. PubMed ID: 27500020
[TBL] [Abstract][Full Text] [Related]
15. National Institute of Standards and Technology high-accuracy cryogenic radiometer.
Gentile TR; Houston JM; Hardis JE; Cromer CL; Parr AC
Appl Opt; 1996 Mar; 35(7):1056-68. PubMed ID: 21085215
[TBL] [Abstract][Full Text] [Related]
16. Comparison of Two Cryogenic Radiometers at NIST.
Houston JM; Livigni DJ
J Res Natl Inst Stand Technol; 2001; 106(4):641-7. PubMed ID: 27500040
[TBL] [Abstract][Full Text] [Related]
17. Long-term temporal stability of the National Institute of Standards and Technology spectral irradiance scale determined with absolute filter radiometers.
Yoon HW; Gibson CE
Appl Opt; 2002 Oct; 41(28):5872-8. PubMed ID: 12371544
[TBL] [Abstract][Full Text] [Related]
18. Optical-Fiber Power Meter Comparison Between NIST and PTB.
Vayshenker I; Haars H; Li X; Lehman JH; Livigni DJ
J Res Natl Inst Stand Technol; 2003; 108(5):391-4. PubMed ID: 27413617
[TBL] [Abstract][Full Text] [Related]
19. Design of a Compact Transfer Radiometer for a Radiometric Benchmark Transfer Chain.
Lei K; Ye X; Xia Z; Xu N; Li S; Zhang Y; Wang Y; Liu Z; Li Z
Sensors (Basel); 2022 Sep; 22(18):. PubMed ID: 36146143
[TBL] [Abstract][Full Text] [Related]
20. ACR II: improved absolute cryogenic radiometer for low background infrared calibrations.
Carter AC; Lorentz SR; Jung TM; Datla RU
Appl Opt; 2005 Feb; 44(6):871-5. PubMed ID: 15751676
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]