114 related articles for article (PubMed ID: 34269753)
21. Use of Texture Analysis on Noncontrast MRI in Classification of Early Stage of Liver Fibrosis.
Zhao R; Gong XJ; Ge YQ; Zhao H; Wang LS; Yu HZ; Liu B
Can J Gastroenterol Hepatol; 2021; 2021():6677821. PubMed ID: 33791254
[No Abstract] [Full Text] [Related]
22. Can magnetic resonance imaging be an alternative to computed tomography in immunocompromised patients with suspected fungal infections? Feasibility of a speed optimized examination protocol at 3 Tesla.
Nagel SN; Wyschkon S; Schwartz S; Hamm B; Elgeti T
Eur J Radiol; 2016 Apr; 85(4):857-63. PubMed ID: 26971435
[TBL] [Abstract][Full Text] [Related]
23. Ultrashort echo time MRI of the lung in children and adolescents: comparison with non-enhanced computed tomography and standard post-contrast T1w MRI sequences.
Renz DM; Herrmann KH; Kraemer M; Boettcher J; Waginger M; Krueger PC; Pfeil A; Streitparth F; Kentouche K; Gruhn B; Mainz JG; Stenzel M; Teichgraeber UK; Reichenbach JR; Mentzel HJ
Eur Radiol; 2022 Mar; 32(3):1833-1842. PubMed ID: 34668994
[TBL] [Abstract][Full Text] [Related]
24. MR imaging of the liver: breath-hold T1-weighted MP-GRE compared with conventional T2-weighted SE imaging--lesion detection, localization, and characterization.
de Lange EE; Mugler JP; Bosworth JE; DeAngelis GA; Gay SB; Hurt NS; Berr SS; Rosenblatt JM; Merickel LW; Harris EK
Radiology; 1994 Mar; 190(3):727-36. PubMed ID: 8115619
[TBL] [Abstract][Full Text] [Related]
25. Feasibility of texture analysis for the assessment of biochemical changes in meniscal tissue on T1 maps calculated from delayed gadolinium-enhanced magnetic resonance imaging of cartilage data: comparison with conventional relaxation time measurements.
Mayerhoefer ME; Welsch GH; Riegler G; Mamisch TC; Materka A; Weber M; El-Rabadi K; Friedrich KM; Dirisamer A; Trattnig S
Invest Radiol; 2010 Sep; 45(9):543-7. PubMed ID: 20661144
[TBL] [Abstract][Full Text] [Related]
26. Colorectal hepatic metastases: detection with SPIO-enhanced breath-hold MR imaging--comparison of optimized sequences.
Ward J; Guthrie JA; Wilson D; Arnold P; Lodge JP; Toogood GJ; Wyatt JI; Robinson PJ
Radiology; 2003 Sep; 228(3):709-18. PubMed ID: 12888620
[TBL] [Abstract][Full Text] [Related]
27. Comparison of in-phase and opposed-phase GRE and conventional SE MR pulse sequences in T1-weighted imaging of liver lesions.
Martín J; Sentis M; Puig J; Rué M; Falcó J; Donoso L; Zidan A
J Comput Assist Tomogr; 1996; 20(6):890-7. PubMed ID: 8933787
[TBL] [Abstract][Full Text] [Related]
28. High Acceleration Three-Dimensional T1-Weighted Dual Echo Dixon Hepatobiliary Phase Imaging Using Compressed Sensing-Sensitivity Encoding: Comparison of Image Quality and Solid Lesion Detectability with the Standard T1-Weighted Sequence.
Nam JG; Lee JM; Lee SM; Kang HJ; Lee ES; Hur BY; Yoon JH; Kim E; Doneva M
Korean J Radiol; 2019 Mar; 20(3):438-448. PubMed ID: 30799575
[TBL] [Abstract][Full Text] [Related]
29. T1-weighted MR image contrast around a cryoablation iceball: a phantom study and initial comparison with in vivo findings.
Overduin CG; Bomers JG; Jenniskens SF; Hoes MF; Ten Haken B; de Lange F; Fütterer JJ; Scheenen TW
Med Phys; 2014 Nov; 41(11):112301. PubMed ID: 25370657
[TBL] [Abstract][Full Text] [Related]
30. STrategically Acquired Gradient Echo (STAGE) imaging, part I: Creating enhanced T1 contrast and standardized susceptibility weighted imaging and quantitative susceptibility mapping.
Chen Y; Liu S; Wang Y; Kang Y; Haacke EM
Magn Reson Imaging; 2018 Feb; 46():130-139. PubMed ID: 29056394
[TBL] [Abstract][Full Text] [Related]
31. MRI-based texture analysis for differentiating pediatric craniofacial rhabdomyosarcoma from infantile hemangioma.
Sarioglu FC; Sarioglu O; Guleryuz H; Ozer E; Ince D; Olgun HN
Eur Radiol; 2020 Oct; 30(10):5227-5236. PubMed ID: 32382846
[TBL] [Abstract][Full Text] [Related]
32. Comparison of high-resolution T1W 3D GRE (LAVA) with 2-point Dixon fat/water separation (FLEX) to T1W fast spin echo (FSE) in prostate cancer (PCa).
Samji K; Alrashed A; Shabana WM; McInnes MD; Bayram E; Schieda N
Clin Imaging; 2016; 40(3):407-13. PubMed ID: 27133677
[TBL] [Abstract][Full Text] [Related]
33. Focal liver disease: comparison of breath-hold T1-weighted MP-GRE MR imaging and contrast-enhanced CT--lesion detection, localization, and characterization.
de Lange EE; Mugler JP; Gay SB; DeAngelis GA; Berr SS; Harris EK
Radiology; 1996 Aug; 200(2):465-73. PubMed ID: 8685343
[TBL] [Abstract][Full Text] [Related]
34. Characterization of adrenal lesions with 1.5-T MRI: preliminary observations on comparison of three in-phase and out-of-phase gradient-echo techniques.
Ramalho M; de Campos RO; Heredia V; Dale BM; Tannaphai P; Azevedo RM; Semelka RC
AJR Am J Roentgenol; 2011 Aug; 197(2):415-23. PubMed ID: 21785088
[TBL] [Abstract][Full Text] [Related]
35. Role of MR texture analysis in histological subtyping and grading of renal cell carcinoma: a preliminary study.
Goyal A; Razik A; Kandasamy D; Seth A; Das P; Ganeshan B; Sharma R
Abdom Radiol (NY); 2019 Oct; 44(10):3336-3349. PubMed ID: 31300850
[TBL] [Abstract][Full Text] [Related]
36. Comparison of Gadolinium-BOPTA and Ferucarbotran-enhanced three-dimensional T1-weighted dynamic liver magnetic resonance imaging in the same patient.
Wersebe A; Wiskirchen J; Decker U; Schick F; Dietz K; Müller-Schimpfle M; Claussen CD; Pereira PL
Invest Radiol; 2006 Mar; 41(3):264-71. PubMed ID: 16481909
[TBL] [Abstract][Full Text] [Related]
37. Estimation of liver function using T2* mapping on gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid enhanced magnetic resonance imaging.
Katsube T; Okada M; Kumano S; Imaoka I; Kagawa Y; Hori M; Ishii K; Tanigawa N; Imai Y; Kudo M; Murakami T
Eur J Radiol; 2012 Jul; 81(7):1460-4. PubMed ID: 21514080
[TBL] [Abstract][Full Text] [Related]
38. Small hepatocellular carcinoma: assessment with T1-weighted spin-echo magnetic resonance imaging with and without fat suppression.
Koushima Y; Ebara M; Fukuda H; Morimoto N; Sugiura N; Yoshikawa M; Sanada M; Saisho H; Matsumoto T; Yukawa M
Eur J Radiol; 2002 Jan; 41(1):34-41. PubMed ID: 11750150
[TBL] [Abstract][Full Text] [Related]
39. Comparison of lesion enhancement between BB Cube and 3D-SPGR images for brain tumors with 1.5-T magnetic resonance imaging.
Hasegawa H; Ashikaga R; Okajima K; Wakayama T; Miyoshi M; Nishimura Y; Murakami T
Jpn J Radiol; 2017 Aug; 35(8):463-471. PubMed ID: 28540464
[TBL] [Abstract][Full Text] [Related]
40. Diagnostic value of MR-based texture analysis for the assessment of hepatic fibrosis in patients with nonalcoholic fatty liver disease (NAFLD).
Cannella R; Borhani AA; Tublin M; Behari J; Furlan A
Abdom Radiol (NY); 2019 May; 44(5):1816-1824. PubMed ID: 30788556
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]