195 related articles for article (PubMed ID: 34271149)
1. Intraoperative Neurophysiology and Transcranial Doppler for Detection of Cerebral Ischemia and Hyperperfusion During Carotid Endarterectomy.
Wang J; Guo L; Holdefer RN; Zhang Y; Liu Q; Gai Q; Zhang W
World Neurosurg; 2021 Oct; 154():e245-e253. PubMed ID: 34271149
[TBL] [Abstract][Full Text] [Related]
2. Comparison of Monitoring of Cerebral Blood Flow by c-FLOW and Transcranial Doppler in Carotid Endarterectomy.
Wang X; Yang B; Ma Y; Gao P; Wang Y; Chen Y; Jiao L; Ling F; Zhao G
World Neurosurg; 2018 Mar; 111():e686-e692. PubMed ID: 29305914
[TBL] [Abstract][Full Text] [Related]
3. Impact of external carotid artery occlusion at declamping of the external and common carotid arteries during carotid endarterectomy on development of new postoperative ischemic cerebral lesions.
Kobayashi M; Yoshida K; Kojima D; Oshida S; Fujiwara S; Kubo Y; Ogasawara K
J Vasc Surg; 2019 Feb; 69(2):454-461. PubMed ID: 29960793
[TBL] [Abstract][Full Text] [Related]
4. Somatosensory Evoked Potential and Transcranial Doppler Monitoring to Guide Shunting in Carotid Endarterectomy.
Seidel K; Jeschko J; Schucht P; Bervini D; Fung C; Krejci V; Z'Graggen W; Fischer U; Arnold M; Goldberg J; Raabe A; Beck J
J Neurol Surg A Cent Eur Neurosurg; 2021 Jul; 82(4):299-307. PubMed ID: 31935785
[TBL] [Abstract][Full Text] [Related]
5. Accuracy of cerebral monitoring in detecting cerebral ischemia during carotid endarterectomy: a comparison of transcranial Doppler sonography, near-infrared spectroscopy, stump pressure, and somatosensory evoked potentials.
Moritz S; Kasprzak P; Arlt M; Taeger K; Metz C
Anesthesiology; 2007 Oct; 107(4):563-9. PubMed ID: 17893451
[TBL] [Abstract][Full Text] [Related]
6. Predictors of cross-clamp-induced intraoperative monitoring changes during carotid endarterectomy using both electroencephalography and somatosensory evoked potentials.
Domenick Sridharan N; Thirumala P; Chaer R; Balzer J; Long B; Crammond D; Makaroun M; Avgerinos E
J Vasc Surg; 2018 Jan; 67(1):191-198. PubMed ID: 28688529
[TBL] [Abstract][Full Text] [Related]
7. Experience of 500 cases of neurophysiological monitoring in carotid endarterectomy.
Stejskal L; Kramár F; Ostrý S; Benes V; Mohapl M; Limberk B
Acta Neurochir (Wien); 2007; 149(7):681-8; discussion 689. PubMed ID: 17585364
[TBL] [Abstract][Full Text] [Related]
8. Continuous intraoperative monitoring of middle cerebral artery blood flow velocities and electroencephalography during carotid endarterectomy. A comparison of the two methods to detect cerebral ischemia.
Arnold M; Sturzenegger M; Schäffler L; Seiler RW
Stroke; 1997 Jul; 28(7):1345-50. PubMed ID: 9227681
[TBL] [Abstract][Full Text] [Related]
9. Comparison of monitoring techniques for intraoperative cerebral ischemia.
Rowed DW; Houlden DA; Burkholder LM; Taylor AB
Can J Neurol Sci; 2004 Aug; 31(3):347-56. PubMed ID: 15376479
[TBL] [Abstract][Full Text] [Related]
10. Hyperperfusion syndrome after carotid endarterectomy and carotid stenting.
Buczek J; Karliński M; Kobayashi A; Białek P; Członkowska A
Cerebrovasc Dis; 2013; 35(6):531-7. PubMed ID: 23817298
[TBL] [Abstract][Full Text] [Related]
11. [Neuromonitoring in carotid surgery: possibilities and limits of transcranial Doppler ultrasound].
Dinkel M; Langer H; Loerler H; Rügheimer E; Schweiger H
Vasa; 1994; 23(4):337-44. PubMed ID: 7817615
[TBL] [Abstract][Full Text] [Related]
12. Warning criteria for MEP monitoring during carotid endarterectomy: a retrospective study of 571 patients.
Malcharek MJ; Hesse J; Hesselbarth K; Thoma K; Wegner C; Sablotzki A; Hennig G; Gille J
J Clin Monit Comput; 2020 Jun; 34(3):589-595. PubMed ID: 31267409
[TBL] [Abstract][Full Text] [Related]
13. Hemodynamic cerebral ischemia during carotid endarterectomy evaluated by intraoperative monitoring and post-operative diffusion-weighted imaging.
Uno M; Suzue A; Nishi K; Nagahiro S
Neurol Res; 2007 Jan; 29(1):70-7. PubMed ID: 17427279
[TBL] [Abstract][Full Text] [Related]
14. Transcranial Doppler sonography and somatosensory evoked potential monitoring in carotid surgery.
Thiel A; Russ W; Zeiler D; Dapper F; Hempelmann G
Eur J Vasc Surg; 1990 Dec; 4(6):597-602. PubMed ID: 2279569
[TBL] [Abstract][Full Text] [Related]
15. Continuous transcranial Doppler ultrasonography and electroencephalography during carotid endarterectomy: a multimodal monitoring system to detect intraoperative ischemia.
Jansen C; Moll FL; Vermeulen FE; van Haelst JM; Ackerstaff RG
Ann Vasc Surg; 1993 Jan; 7(1):95-101. PubMed ID: 8518125
[TBL] [Abstract][Full Text] [Related]
16. Association of intraoperative transcranial doppler monitoring variables with stroke from carotid endarterectomy.
Ackerstaff RG; Moons KG; van de Vlasakker CJ; Moll FL; Vermeulen FE; Algra A; Spencer MP
Stroke; 2000 Aug; 31(8):1817-23. PubMed ID: 10926940
[TBL] [Abstract][Full Text] [Related]
17. Early detection of cerebral ischemia during carotid endarterectomy using transcranial Doppler sonography and somatosensory evoked potentials.
Thiel A; Russ W; Nestle HW; Hempelmann G
Thorac Cardiovasc Surg; 1989 Apr; 37(2):115-8. PubMed ID: 2727982
[TBL] [Abstract][Full Text] [Related]
18. The Efficacy of Near-Infrared Spectroscopy Monitoring in Carotid Endarterectomy: A Prospective, Single-Center, Observational Study.
Wang Y; Li L; Wang T; Zhao L; Feng H; Wang Q; Fan L; Feng X; Xiao W; Feng K
Cell Transplant; 2019 Feb; 28(2):170-175. PubMed ID: 30545240
[TBL] [Abstract][Full Text] [Related]
19. Transcranial Doppler 24 Hours after Carotid Endarterectomy Accurately Identifies Patients Not at Risk of Cerebral Hyperperfusion Syndrome.
Fassaert LMM; Immink RV; van Vriesland DJ; de Vries JPM; Toorop RJ; Kappelle LJ; Westerink J; Tromp SC; de Borst GJ
Eur J Vasc Endovasc Surg; 2019 Sep; 58(3):320-327. PubMed ID: 31350134
[TBL] [Abstract][Full Text] [Related]
20. Transcranial Doppler monitoring during carotid endarterectomy: a technical case report.
Heyer EJ; Winfree CJ; Mack WJ; Connolly ES
J Neurosurg Anesthesiol; 2000 Jul; 12(3):233-9. PubMed ID: 10905573
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]