These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
151 related articles for article (PubMed ID: 34272973)
1. Custom TKA: what to expect and where do we stand today? Victor J; Vermue H Arch Orthop Trauma Surg; 2021 Dec; 141(12):2195-2203. PubMed ID: 34272973 [TBL] [Abstract][Full Text] [Related]
2. Contemporary knee arthroplasty: one fits all or time for diversity? Beckmann J; Meier MK; Benignus C; Hecker A; Thienpont E Arch Orthop Trauma Surg; 2021 Dec; 141(12):2185-2194. PubMed ID: 34269891 [TBL] [Abstract][Full Text] [Related]
3. Higher Frequency of Reoperation With a New Bicruciate-retaining Total Knee Arthroplasty. Christensen JC; Brothers J; Stoddard GJ; Anderson MB; Pelt CE; Gililland JM; Peters CL Clin Orthop Relat Res; 2017 Jan; 475(1):62-69. PubMed ID: 27043727 [TBL] [Abstract][Full Text] [Related]
4. Satisfactory mid-term outcomes of condylar-constrained knee implants in primary total knee arthroplasty: clinical and radiological follow-up. Mancino F; De Martino I; Burrofato A; De Ieso C; Saccomanno MF; Maccauro G; De Santis V J Orthop Traumatol; 2020 Dec; 21(1):22. PubMed ID: 33263831 [TBL] [Abstract][Full Text] [Related]
5. A cruciate-retaining implant can treat both knees of most windswept deformities when performed with calipered kinematically aligned TKA. Howell SM; Shelton TJ; Gill M; Hull ML Knee Surg Sports Traumatol Arthrosc; 2021 Feb; 29(2):437-445. PubMed ID: 32239272 [TBL] [Abstract][Full Text] [Related]
6. Long-term results of revision total knee arthroplasty using a rotating hinge implant. Wignadasan W; Chang JS; Kayani B; Kontoghiorghe C; Haddad FS Knee; 2021 Jan; 28():72-80. PubMed ID: 33310668 [TBL] [Abstract][Full Text] [Related]
7. Improved Range of Motion and Patient-Reported Outcome Scores With Fixed-Bearing Revision Total Knee Arthroplasty for Suboptimal Axial Implant Rotation. Amanatullah DF; Lichstein PM; Lundergan WG; Wong WW; Maloney WJ; Goodman SB; Huddleston JI J Arthroplasty; 2019 Jun; 34(6):1174-1178. PubMed ID: 30853158 [TBL] [Abstract][Full Text] [Related]
8. The Mark Coventry Award: Custom Cutting Guides Do Not Improve Total Knee Arthroplasty Clinical Outcomes at 2 Years Followup. Nam D; Park A; Stambough JB; Johnson SR; Nunley RM; Barrack RL Clin Orthop Relat Res; 2016 Jan; 474(1):40-6. PubMed ID: 25712865 [TBL] [Abstract][Full Text] [Related]
9. Computer-navigated minimally invasive total knee arthroplasty for patients with retained implants in the femur. Lin SY; Chen CH; Huang PJ; Fu YC; Huang HT Kaohsiung J Med Sci; 2014 Aug; 30(8):415-21. PubMed ID: 25002380 [TBL] [Abstract][Full Text] [Related]
10. [Restricted motion after total knee arthroplasty]. Kucera T; Urban K; Karpas K; Sponer P Acta Chir Orthop Traumatol Cech; 2007 Oct; 74(5):326-31. PubMed ID: 18001629 [TBL] [Abstract][Full Text] [Related]
12. Component placement accuracy in two generations of handheld robotics-assisted knee arthroplasty. Sicat CS; Chow JC; Kaper B; Mitra R; Xie J; Schwarzkopf R Arch Orthop Trauma Surg; 2021 Dec; 141(12):2059-2067. PubMed ID: 34304279 [TBL] [Abstract][Full Text] [Related]
13. Tibiofemoral conformity variation offers changed kinematics and wear performance of customized posterior-stabilized total knee arthroplasty. Koh YG; Son J; Kwon OR; Kwon SK; Kang KT Knee Surg Sports Traumatol Arthrosc; 2019 Apr; 27(4):1213-1223. PubMed ID: 29974167 [TBL] [Abstract][Full Text] [Related]
14. Patient-specific implants with custom cutting blocks better approximate natural knee kinematics than standard TKA without custom cutting blocks. Patil S; Bunn A; Bugbee WD; Colwell CW; D'Lima DD Knee; 2015 Dec; 22(6):624-9. PubMed ID: 27092379 [TBL] [Abstract][Full Text] [Related]
15. One-stage total knee arthroplasty for patients with osteoarthritis of the knee and extra-articular deformity. Xiao-Gang Z; Shahzad K; Li C Int Orthop; 2012 Dec; 36(12):2457-63. PubMed ID: 23132502 [TBL] [Abstract][Full Text] [Related]
16. Good mid-term outcome of the rotating hinge knee in primary total knee arthroplasty - Results of a single center cohort of 106 knees with a median follow-up of 6.3 years. Hintze JV; Niemeläinen M; Sintonen H; Nieminen J; Eskelinen A Knee; 2021 Jan; 28():273-281. PubMed ID: 33453516 [TBL] [Abstract][Full Text] [Related]
17. Improved clinical outcomes after revision arthroplasty with a hinged implant for severely stiff total knee arthroplasty. van Rensch PJH; Heesterbeek PJC; Hannink G; van Hellemondt GG; Wymenga AB Knee Surg Sports Traumatol Arthrosc; 2019 Apr; 27(4):1043-1048. PubMed ID: 30367195 [TBL] [Abstract][Full Text] [Related]
18. Knee joint kinematics, fixation and function related to joint area design in total knee arthroplasty. Uvehammer J Acta Orthop Scand Suppl; 2001 Feb; 72(299):1-52. PubMed ID: 11381581 [TBL] [Abstract][Full Text] [Related]
19. Polyethylene Damage Increases With Varus Implant Alignment in Posterior-stabilized and Constrained Condylar Knee Arthroplasty. Li Z; Esposito CI; Koch CN; Lee YY; Padgett DE; Wright TM Clin Orthop Relat Res; 2017 Dec; 475(12):2981-2991. PubMed ID: 28822068 [TBL] [Abstract][Full Text] [Related]
20. Cementless 3D Printed Highly Porous Titanium-Coated Baseplate Total Knee Arthroplasty: Survivorship and Outcomes at 2-Year Minimum Follow-Up. Sultan AA; Mahmood B; Samuel LT; Stearns KL; Molloy RM; Moskal JT; Krebs VE; Harwin SF; Mont MA J Knee Surg; 2020 Mar; 33(3):279-283. PubMed ID: 30727020 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]