These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

401 related articles for article (PubMed ID: 34275219)

  • 21. Marginal discrepancy of CAD-CAM complete-arch fixed implant-supported frameworks.
    Yilmaz B; Kale E; Johnston WM
    J Prosthet Dent; 2018 Jul; 120(1):65-70. PubMed ID: 29475755
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Influence of implant framework and mandibular flexure on the strain distribution on a Kennedy class II mandible restored with a long-span implant fixed restoration: a pilot study.
    Law C; Bennani V; Lyons K; Swain M
    J Prosthet Dent; 2014 Jul; 112(1):31-7. PubMed ID: 24388719
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Adaptation of cobalt chromium frameworks fabricated by conventional versus selective laser melting techniques: An in vitro and clinical assessment.
    Elhadery SS; Alhajj MN; Yunus N; Ibrahim N; Abidin ZZ; Ahmad SF; Salleh NM
    J Prosthet Dent; 2024 Apr; ():. PubMed ID: 38627176
    [TBL] [Abstract][Full Text] [Related]  

  • 24. In vitro fit of CAD-CAM complete arch screw-retained titanium and zirconia implant prostheses fabricated on 4 implants.
    Al-Meraikhi H; Yilmaz B; McGlumphy E; Brantley W; Johnston WM
    J Prosthet Dent; 2018 Mar; 119(3):409-416. PubMed ID: 28720339
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Accuracy and surface roughness of Co-Cr partial denture frameworks with different digital fabrication methods.
    Heiba IM; Mohamed SL; Sabet ME
    J Prosthet Dent; 2024 Mar; 131(3):520.e1-520.e7. PubMed ID: 38135640
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Fit of 3Y-TZP complete-arch implant-supported fixed dental prostheses before and after porcelain veneering.
    Svanborg P; Norström Saarva V; Stenport V; Eliasson A
    J Prosthet Dent; 2019 Aug; 122(2):137-141. PubMed ID: 30885581
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Effect of Reinforcement Bar on Trueness of Printed Titanium Kennedy I Removable Partial Denture Frameworks by Selective Laser Melting.
    Zhang L; Yi Y; Ding L; Meng J; Wu G
    Int Dent J; 2024 Jul; ():. PubMed ID: 39034209
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Adaptation of removable partial denture frameworks fabricated by selective laser melting.
    Chen H; Li H; Zhao Y; Zhang X; Wang Y; Lyu P
    J Prosthet Dent; 2019 Sep; 122(3):316-324. PubMed ID: 30922559
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Microstructure, mechanical properties, and retentive forces of cobalt-chromium removable partial denture frameworks fabricated by selective laser melting followed by heat treatment.
    Lee WF; Wang JC; Hsu CY; Peng PW
    J Prosthet Dent; 2022 Jan; 127(1):115-121. PubMed ID: 33234303
    [TBL] [Abstract][Full Text] [Related]  

  • 30. The precision of fit of cast and milled full-arch implant-supported restorations.
    Paniz G; Stellini E; Meneghello R; Cerardi A; Gobbato EA; Bressan E
    Int J Oral Maxillofac Implants; 2013; 28(3):687-93. PubMed ID: 23748298
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [Finite element analyses of retention of removable partial denture circumferential clasps manufactured by selective laser melting].
    Ma KN; Chen H; Shen YR; Zhou YS; Wang Y; Sun YC
    Beijing Da Xue Xue Bao Yi Xue Ban; 2022 Feb; 54(1):105-112. PubMed ID: 35165476
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Effects of 3 kinds of processing techniques on the fitness of metal clasp.
    Yin X; Zhou H; Yan F; Wu X; Wu G; Pang D
    Zhong Nan Da Xue Xue Bao Yi Xue Ban; 2021 Oct; 46(10):1122-1128. PubMed ID: 34911843
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Ratios of Cantilever Lengths and Anterior-Posterior Spreads of Definitive Hybrid Full-Arch, Screw-Retained Prostheses: Results of a Clinical Study.
    Drago C
    J Prosthodont; 2018 Jun; 27(5):402-408. PubMed ID: 27416302
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Precision of fit of implant-supported screw-retained 10-unit computer-aided-designed and computer-aided-manufactured frameworks made from zirconium dioxide and titanium: an in vitro study.
    Katsoulis J; Mericske-Stern R; Rotkina L; Zbären C; Enkling N; Blatz MB
    Clin Oral Implants Res; 2014 Feb; 25(2):165-74. PubMed ID: 23025489
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Fit of cobalt-chromium implant frameworks before and after ceramic veneering in comparison with CNC-milled titanium frameworks.
    Svanborg P; Stenport V; Eliasson A
    Clin Exp Dent Res; 2015 Dec; 1(2):49-56. PubMed ID: 29744140
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Evaluation of strain distribution on an edentulous mandible generated by cobalt-chromium metal alloy fixed complete dentures fabricated with different techniques: An in vitro study.
    Taşın S; Turp I; Bozdağ E; Sünbüloğlu E; Üşümez A
    J Prosthet Dent; 2019 Jul; 122(1):47-53. PubMed ID: 30782458
    [TBL] [Abstract][Full Text] [Related]  

  • 37. An In Vitro Investigation of Accuracy and Fit of Conventional and CAD/CAM Removable Partial Denture Frameworks.
    Soltanzadeh P; Suprono MS; Kattadiyil MT; Goodacre C; Gregorius W
    J Prosthodont; 2019 Jun; 28(5):547-555. PubMed ID: 30407685
    [TBL] [Abstract][Full Text] [Related]  

  • 38. The Fit Accuracy of Removable Partial Denture Metal Frameworks Using Conventional and 3D Printed Techniques: An
    Bajunaid SO; Altwaim B; Alhassan M; Alammari R
    J Contemp Dent Pract; 2019 Apr; 20(4):476-481. PubMed ID: 31308280
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Application of Ce-TZP/Al
    Hagiwara Y; Nakajima K
    J Prosthodont Res; 2016 Oct; 60(4):337-343. PubMed ID: 26944223
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Process parameter optimization for removable partial denture frameworks manufactured by selective laser melting.
    Hwang S; An S; Robles U; Rumpf RC
    J Prosthet Dent; 2023 Jan; 129(1):191-198. PubMed ID: 34119322
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 21.