These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

141 related articles for article (PubMed ID: 34275570)

  • 21. A paramedian approach for dorsal root ganglion stimulation placement developed to limit lead migration and fracture.
    Chapman KB; Spiegel MA; Dickerson DM; Billet B; Patel KV; Hunter C; Antony A; van Helmond N; Deer T; Kallewaard JW; Hagedorn JM; Yang A
    Pain Pract; 2021 Nov; 21(8):991-1000. PubMed ID: 34328256
    [TBL] [Abstract][Full Text] [Related]  

  • 22. The utility of bone cement to prevent lead migration with minimally invasive placement of spinal cord stimulator laminectomy leads.
    Connor DE; Cangiano-Heath A; Brown B; Vidrine R; Battley T; Nanda A; Guthikonda B
    Neurosurgery; 2012 Jul; 71(1):157-63. PubMed ID: 22314753
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Cephalad Lead Migration During a Spinal Cord Stimulation Trial: A Case Presentation.
    Agubuzu O; Beckworth WJ
    PM R; 2018 Jan; 10(1):101-104. PubMed ID: 28606836
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Significant cephalad paddle-lead migration after lumbar spinal cord stimulation implant.
    Di Santo S; Ravera E
    Neuromodulation; 2014 Jun; 17(4):385. PubMed ID: 23837525
    [No Abstract]   [Full Text] [Related]  

  • 25. Cervical and cervicomedullary spinal cord stimulation for chronic pain: efficacy and outcomes.
    Chivukula S; Tempel ZJ; Weiner GM; Gande AV; Chen CJ; Ding D; Moossy JJ
    Clin Neurol Neurosurg; 2014 Dec; 127():33-41. PubMed ID: 25314370
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Incidence of clinically significant percutaneous spinal cord stimulator lead migration.
    Gazelka HM; Freeman ED; Hooten WM; Eldrige JS; Hoelzer BC; Mauck WD; Moeschler SM; Pingree MJ; Rho RH; Lamer TJ
    Neuromodulation; 2015 Feb; 18(2):123-5; discussion 125. PubMed ID: 24796230
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Spinal cord stimulators in an outpatient interventional neuroradiology practice.
    Padwal J; Georgy MM; Georgy BA
    J Neurointerv Surg; 2014 Nov; 6(9):708-11. PubMed ID: 24151115
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Incidence and Risk Factors for Spinal Cord Stimulator Lead Migration With or Without Loss of Efficacy: A Retrospective Review of 91 Consecutive Thoracic Lead Implants.
    Dombovy-Johnson ML; D'Souza RS; Ha CT; Hagedorn JM
    Neuromodulation; 2022 Jul; 25(5):731-737. PubMed ID: 35803679
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Is spinal cord stimulation safe? A review of its complications.
    Bendersky D; Yampolsky C
    World Neurosurg; 2014 Dec; 82(6):1359-68. PubMed ID: 23851231
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Spinal Cord Stimulator Electrode Dislodging into the Ligamentum Flavum: A Case Report.
    Martin AJ; Padalia D; Shah N; Singh J; Jassal N
    Pain Pract; 2018 Sep; 18(7):884-888. PubMed ID: 29436158
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Contact dissociation from paddle leads: a report of two cases.
    Amrani J
    Neuromodulation; 2014 Apr; 17(3):282-5. PubMed ID: 24033922
    [No Abstract]   [Full Text] [Related]  

  • 32. Incidence of Revision Surgery in a Large Cohort of Patients With Thoracic Surgical Three-Column Paddle Leads: A Retrospective Case Review.
    Pahapill PA
    Neuromodulation; 2015 Jul; 18(5):367-75. PubMed ID: 25251044
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Spinal cord stimulator and epidural haematoma.
    Takawira N; Han RJ; Nguyen TQ; Gaines JD; Han TH
    Br J Anaesth; 2012 Oct; 109(4):649-50. PubMed ID: 22976866
    [No Abstract]   [Full Text] [Related]  

  • 34. First Report of Extraspinal Lead Migration Along a Thoracic Spinal Nerve After Spinal Cord Stimulation.
    Ridwan S; Ostertun B; Stubbe H; Hans FJ
    World Neurosurg; 2020 Sep; 141():247-250. PubMed ID: 32540296
    [TBL] [Abstract][Full Text] [Related]  

  • 35. New technique for open placement of paddle-type spinal cord stimulator electrode in presence of epidural scar tissue.
    Pabaney AH; Robin AM; Schwalb JM
    Neuromodulation; 2014 Dec; 17(8):759-62; discussion 762. PubMed ID: 24725098
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Compression of Thoracic Spinal Cord with Decreased Cerebrospinal Fluid Space After Implantation of Paddle Lead Spinal Cord Stimulation at T9: A Three-Dimensional Myelographic Computed Tomography Study.
    Son BC; Ko HC; Choi JG
    World Neurosurg; 2018 Oct; 118():e323-e334. PubMed ID: 29969740
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Radiographic lead migration in percutaneous spinal cord stimulator trials.
    Mullins CF; Royds J; Al-Kaisy A
    Reg Anesth Pain Med; 2024 May; 49(5):332-338. PubMed ID: 37479237
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Care Bundle Approach to Minimizing Infection Rates after Neurosurgical Implants for Neuromodulation: A Single-Surgeon Experience.
    Arocho-Quinones EV; Huang CC; Ward BD; Pahapill PA
    World Neurosurg; 2019 Aug; 128():e87-e97. PubMed ID: 30986582
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Risk Factors Associated with Lead Migration Requiring Revision in Dorsal Root Ganglion Stimulation.
    Abraham ME; Potdar A; Ward M; Herschman Y; Mammis A
    World Neurosurg; 2019 Aug; 128():e649-e652. PubMed ID: 31054337
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Spontaneous Ascending Migration of a Paddle Lead.
    Paz Solis J; Román Aragón M
    Neuromodulation; 2019 Apr; 22(3):361-363. PubMed ID: 30786084
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.