143 related articles for article (PubMed ID: 34278097)
1. A novel partially covered metallic stent with a 20-mm long distal bare portion for EUS-guided hepaticogastrostomy.
Asai S; Takeshita K; Ichinona T; Akamine E; Fujimoto N
VideoGIE; 2021 Jul; 6(7):322-324. PubMed ID: 34278097
[TBL] [Abstract][Full Text] [Related]
2. Endoscopic ultrasonography-guided hepaticogastrostomy using a novel laser-cut type partially covered self-expandable metal stent (with video).
Ogura T; Kitano M; Okuda A; Itonaga M; Ueno S; Yamashita Y; Nishioka N; Ashida R; Miyano A; Higuchi K
Dig Endosc; 2021 Nov; 33(7):1188-1193. PubMed ID: 34318527
[TBL] [Abstract][Full Text] [Related]
3. A pilot study of Spring Stopper Stents: Novel partially covered self-expandable metallic stents with anti-migration properties for EUS-guided hepaticogastrostomy.
Ishii S; Isayama H; Sasahira N; Matsubara S; Nakai Y; Fujisawa T; Tomishima K; Sasaki T; Ishigaki K; Kogure H; Okamoto T; Otsuka T; Takasaki Y; Suzuki A
Endosc Ultrasound; 2023; 12(2):266-272. PubMed ID: 37148139
[TBL] [Abstract][Full Text] [Related]
4. Risk Factors for Stent Migration into the Abdominal Cavity after Endoscopic Ultrasound-Guided Hepaticogastrostomy.
Ochiai K; Fujisawa T; Ishii S; Suzuki A; Saito H; Takasaki Y; Ushio M; Takahashi S; Yamagata W; Tomishima K; Hisamatsu T; Isayama H
J Clin Med; 2021 Jul; 10(14):. PubMed ID: 34300277
[No Abstract] [Full Text] [Related]
5. Outcomes of partially covered self-expandable metal stents with different uncovered lengths in endoscopic ultrasound-guided hepaticogastrostomy: a Japanese retrospective study.
Okamoto T; Sasaki T; Takeda T; Hirai T; Ishitsuka T; Yamada M; Nakagawa H; Mie T; Furukawa T; Kasuga A; Ozaka M; Sasahira N
Clin Endosc; 2024 May; ():. PubMed ID: 38725401
[TBL] [Abstract][Full Text] [Related]
6. Preliminary feasibility study of a new partially covered self-expandable metal stent with an anchoring flange for EUS-guided hepaticogastrostomy (with videos).
Shin IS; Moon JH; Lee YN; Myeong JH; Lee TH; Yang JK; Cho YD; Park SH; Giovannini M
Gastrointest Endosc; 2023 Nov; 98(5):848-856. PubMed ID: 37473968
[TBL] [Abstract][Full Text] [Related]
7. Endoscopic Ultrasound-Guided Gallbladder Drainage for Aberrant Right Posterior Duct Obstruction Developing after Placement of a Covered Self-Expandable Metallic Stent in a Patient with Distal Biliary Obstruction.
Suzuki Y; Hashimoto Y; Shibuki T; Kan M; Kimura G; Umemoto K; Watanabe K; Sasaki M; Takahashi H; Imaoka H; Ohno I; Mitsunaga S; Ikeda M
Case Rep Gastroenterol; 2018; 12(3):722-728. PubMed ID: 30631259
[TBL] [Abstract][Full Text] [Related]
8. Long-term outcomes of a long, partially covered metal stent for EUS-guided hepaticogastrostomy in patients with malignant biliary obstruction (with video).
Nakai Y; Sato T; Hakuta R; Ishigaki K; Saito K; Saito T; Takahara N; Hamada T; Mizuno S; Kogure H; Nogchi K; Ito Y; Isayama H; Koike K
Gastrointest Endosc; 2020 Sep; 92(3):623-631.e1. PubMed ID: 32278705
[TBL] [Abstract][Full Text] [Related]
9. EUS-Guided hepaticogastrostomy in a pregnant patient with Roux-en-Y hepaticojejunostomy anatomy.
Bhalla S; Sondhi A; Prabhu A; Law R
VideoGIE; 2022 Aug; 7(8):287-288. PubMed ID: 36034067
[TBL] [Abstract][Full Text] [Related]
10. Endoscopic ultrasound-guided hepaticogastrostomy or hepaticojejunostomy without dilation using a stent with a thinner delivery system.
Maehara K; Hijioka S; Nagashio Y; Ohba A; Maruki Y; Suzuki H; Sone M; Okusaka T; Saito Y
Endosc Int Open; 2020 Aug; 8(8):E1034-E1038. PubMed ID: 32743055
[No Abstract] [Full Text] [Related]
11. Safety and effectiveness of a long, partially covered metal stent for endoscopic ultrasound-guided hepaticogastrostomy in patients with malignant biliary obstruction.
Nakai Y; Isayama H; Yamamoto N; Matsubara S; Ito Y; Sasahira N; Hakuta R; Umefune G; Takahara N; Hamada T; Mizuno S; Kogure H; Tada M; Koike K
Endoscopy; 2016 Dec; 48(12):1125-1128. PubMed ID: 27716860
[No Abstract] [Full Text] [Related]
12. The intra-conduit release method is useful for avoiding migration of metallic stents during EUS-guided hepaticogastrostomy (with video).
Uchida D; Kawamoto H; Kato H; Goto D; Tomoda T; Matsumoto K; Yamamoto N; Horiguchi S; Tsutsumi K; Okada H
J Med Ultrason (2001); 2018 Jul; 45(3):399-403. PubMed ID: 29235065
[TBL] [Abstract][Full Text] [Related]
13. Outcomes of EUS-guided choledochoduodenostomy as primary drainage for distal biliary obstruction with covered self-expandable metallic stents.
Kuraoka N; Hara K; Okuno N; Kuwahara T; Mizuno N; Shimizu Y; Niwa Y; Terai S
Endosc Int Open; 2020 Jul; 8(7):E861-E868. PubMed ID: 32617390
[No Abstract] [Full Text] [Related]
14. Use of partially covered and uncovered metallic prosthesis for endoscopic ultrasound-guided hepaticogastrostomy: Results of a retrospective monocentric study.
De Cassan C; Bories E; Pesenti C; Caillol F; Godat S; Ratone JP; Delpero JR; Ewald J; Giovannini M
Endosc Ultrasound; 2017; 6(5):329-335. PubMed ID: 28685745
[TBL] [Abstract][Full Text] [Related]
15. Partially covered self-expandable metal stent with antimigratory single flange plays important role during EUS-guided hepaticogastrostomy.
Yamamura M; Ogura T; Ueno S; Okuda A; Nishioka N; Yamada M; Ueshima K; Matsuno J; Yamamoto Y; Higuchi K
Endosc Int Open; 2022 Feb; 10(2):E209-E214. PubMed ID: 35178339
[No Abstract] [Full Text] [Related]
16. Efficacy of the 6-mm fully covered self-expandable metal stent during endoscopic ultrasound-guided hepaticogastrostomy as a primary biliary drainage for the cases estimated difficult endoscopic retrograde cholangiopancreatography: A prospective clinical study.
Okuno N; Hara K; Mizuno N; Kuwahara T; Iwaya H; Ito A; Kuraoka N; Matsumoto S; Polmanee P; Niwa Y
J Gastroenterol Hepatol; 2018 Jul; 33(7):1413-1421. PubMed ID: 29424011
[TBL] [Abstract][Full Text] [Related]
17. Stent selection and tips on placement technique of EUS-guided biliary drainage: transduodenal and transgastric stenting.
Itoi T; Isayama H; Sofuni A; Itokawa F; Kurihara T; Tsuchiya T; Tsuji S; Ishii K; Ikeuchi N; Tanaka R; Umeda J; Moriyasu F; Kawakami H
J Hepatobiliary Pancreat Sci; 2011 Sep; 18(5):664-72. PubMed ID: 21688214
[TBL] [Abstract][Full Text] [Related]
18. Stent length is impact factor associated with stent patency in endoscopic ultrasound-guided hepaticogastrostomy.
Ogura T; Yamamoto K; Sano T; Onda S; Imoto A; Masuda D; Takagi W; Fukunishi S; Higuchi K
J Gastroenterol Hepatol; 2015 Dec; 30(12):1748-52. PubMed ID: 26083496
[TBL] [Abstract][Full Text] [Related]
19. Combination of endoscopic retrograde cholangiopancreatography and endoscopic ultrasonography-guided biliary drainage in malignant hilar biliary obstruction.
Kongkam P; Tasneem AA; Rerknimitr R
Dig Endosc; 2019 Apr; 31 Suppl 1():50-54. PubMed ID: 30994233
[TBL] [Abstract][Full Text] [Related]
20. Endoscopic treatment for distal malignant biliary obstruction.
Matsumoto K; Takeda Y; Onoyama T; Kawata S; Kurumi H; Koda H; Yamashita T; Isomoto H
Ann Transl Med; 2017 Apr; 5(8):190. PubMed ID: 28616405
[TBL] [Abstract][Full Text] [Related]