These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

109 related articles for article (PubMed ID: 34289232)

  • 41. Mixed oxides prosthetic ceramic ball heads. Part 1: effect of the ZrO2 fraction on the wear of ceramic on polythylene joints.
    Affatato S; Testoni M; Cacciari GL; Toni A
    Biomaterials; 1999 May; 20(10):971-5. PubMed ID: 10353651
    [TBL] [Abstract][Full Text] [Related]  

  • 42. The John Charnley Award: an accurate and extremely sensitive method to separate, display, and characterize wear debris: part 2: metal and ceramic particles.
    Billi F; Benya P; Kavanaugh A; Adams J; McKellop H; Ebramzadeh E
    Clin Orthop Relat Res; 2012 Feb; 470(2):339-50. PubMed ID: 21932105
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Macrophage inhibits the osteogenesis of fibroblasts in ultrahigh molecular weight polyethylene (UHMWPE) wear particle-induced osteolysis.
    Lei P; Dai Z; Zhang YS; Liu H; Niu W; Li K; Wang L; Hu Y; Xie J
    J Orthop Surg Res; 2019 Mar; 14(1):80. PubMed ID: 30885228
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Is ceramic-on-ceramic squeaking phenomenon reproducible in vitro? A long-term simulator study under severe conditions.
    Affatato S; Traina F; Mazzega-Fabbro C; Sergo V; Viceconti M
    J Biomed Mater Res B Appl Biomater; 2009 Oct; 91(1):264-71. PubMed ID: 19422051
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Sodium-azide versus ProClin 300: influence on the morphology of UHMWPE particles generated in laboratory tests.
    Affatato S; Bersaglia G; Emiliani D; Foltran I; Toni A
    Biomaterials; 2004 Feb; 25(5):835-42. PubMed ID: 14609672
    [TBL] [Abstract][Full Text] [Related]  

  • 46. The influence of lubricant on the morphology of ultra-high molecular weight polyethylene wear debris generated in laboratory tests.
    Besong AA; Tipper JL; Mathews BJ; Ingham E; Stone MH; Fisher J
    Proc Inst Mech Eng H; 1999; 213(2):155-8. PubMed ID: 10333687
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Influence of gelatin and bovine serum lubricants on ultra-high molecular weight polyethylene wear debris generated in in vitro simulations.
    Bell J; Besong AA; Tipper JL; Ingham E; Wroblewski BM; Stone MH; Fisher J
    Proc Inst Mech Eng H; 2000; 214(5):513-8. PubMed ID: 11109859
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Comparative wear and wear debris under three different counterface conditions of crosslinked and non-crosslinked ultra high molecular weight polyethylene.
    Endo MM; Barbour PS; Barton DC; Fisher J; Tipper JL; Ingham E; Stone MH
    Biomed Mater Eng; 2001; 11(1):23-35. PubMed ID: 11281576
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Carbon-carbon composite bearing materials in hip arthroplasty: analysis of wear and biological response to wear debris.
    Howling GI; Ingham E; Sakoda H; Stewart TD; Fisher J; Antonarulrajah A; Appleyard S; Rand B
    J Mater Sci Mater Med; 2004 Jan; 15(1):91-8. PubMed ID: 15338596
    [TBL] [Abstract][Full Text] [Related]  

  • 50. A comparison of the wear and physical properties of silane cross-linked polyethylene and ultra-high molecular weight polyethylene.
    Sakoda H; Voice AM; McEwen HM; Isaac GH; Hardaker C; Wroblewski BM; Fisher J
    J Arthroplasty; 2001 Dec; 16(8):1018-23. PubMed ID: 11740757
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Influence of analyzed lubricant volumes on the amount and characteristics of generated wear particles from three different types of polyethylene liner materials.
    Markhoff J; Zietz C; Fabry C; Fulda G; Bader R
    J Biomed Mater Res B Appl Biomater; 2018 Apr; 106(3):1299-1306. PubMed ID: 28636252
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Comparative study of the wear of UHMWPE with zirconia ceramic and stainless steel femoral heads in artificial hip joints.
    Derbyshire B; Fisher J; Dowson D; Hardaker C; Brummitt K
    Med Eng Phys; 1994 May; 16(3):229-36. PubMed ID: 8061909
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Ultra-low wear rates for rigid-on-rigid bearings in total hip replacements.
    Clarke IC; Good V; Williams P; Schroeder D; Anissian L; Stark A; Oonishi H; Schuldies J; Gustafson G
    Proc Inst Mech Eng H; 2000; 214(4):331-47. PubMed ID: 10997055
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Ceramic prosthesis surfaces induce an inflammatory cell response and fibrotic tissue changes.
    Bertrand J; Delfosse D; Mai V; Awiszus F; Harnisch K; Lohmann CH
    Bone Joint J; 2018 Jul; 100-B(7):882-890. PubMed ID: 29954216
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Surface characterization and debris analysis of ceramic pairings after ten million cycles on a hip joint simulator.
    Affatato S; Ferrari G; Chevalier J; Ruggeri O; Toni A
    Proc Inst Mech Eng H; 2002; 216(6):419-24. PubMed ID: 12502006
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Characteristics of metal and ceramic total hip bearing surfaces and their effect on long-term ultra high molecular weight polyethylene wear.
    Davidson JA
    Clin Orthop Relat Res; 1993 Sep; (294):361-78. PubMed ID: 8358943
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Wear of ultra-high molecular weight polyethylene acetabular cups in a physiological hip joint simulator in the anatomical position using bovine serum as a lubricant.
    Bigsby RJ; Hardaker CS; Fisher J
    Proc Inst Mech Eng H; 1997; 211(3):265-9. PubMed ID: 9256003
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Hard bearing surfaces in total hip arthroplasty.
    Jazrawi LM; Kummer FJ; Di Cesare PE
    Am J Orthop (Belle Mead NJ); 1998 Apr; 27(4):283-92. PubMed ID: 9586727
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Cross-linked ultra-high-molecular weight polyethylene liner and ceramic femoral head in total hip arthroplasty: a prospective study at 5 years follow-up.
    Orradre Burusco I; Romero R; Brun M; López Blasco JJ
    Arch Orthop Trauma Surg; 2011 Dec; 131(12):1711-6. PubMed ID: 21739116
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Frictional heating of bearing materials tested in a hip joint wear simulator.
    Lu Z; McKellop H
    Proc Inst Mech Eng H; 1997; 211(1):101-8. PubMed ID: 9141895
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.